      BenTing BGDW-100 Low Temperature Test Chamber
      In coming
      ChinaChina
      Detail
      HUDA QD-E708-1000K60-X5 Rapid temperature change Test Chamber
      109170.0 RMB
      ChinaChina
      Detail
      Model comparison
      Type constant temperature alternating
      Min-TEMP -60℃ -60℃
      Max-TEMP 150℃
      working Volume ≤100L 501~1000L
      Parameter comparison
      Temperature range -60~0℃ -60~150℃
      Humidity control range 20~98%R.H
      Interior Volume 100L 1000L
      Heating rate 1~3℃/min
      Internal Dimensions of test chamber 500 * 400 * 500Mm (width * depth * height)
      Temperature Fluctuation ±0.5℃ ±0.5℃
      Temperature Uniformity ±1.5℃ ≤2℃
      Heating rate 1~3℃/min
      Cooling rate 70.7~ 1.2 ℃/min, (non-linear no-load)
      Controller Accuracy range Temperature +/- 0.1 ℃, Humidity +/- 0.1% R.H
      Temperature transducer Platinum resistor PT100Ω
      Heating system Nickel chromium alloy electric heating heater Nickel alloy heating pipe, Circulating Fan, P.I.D control heating
      Refrigeration system Fully enclosed air-cooled single-stage compression refrigeration/original French "Taikang"/Fully enclosed air-cooled cascade compression refrigeration Low temperature compressor imported from GermanyLow noise air-cooled chilled down water tower (optional)
      Circulatory system High temperature and low noise centrifugal motor, multi-blade centrifugal wind turbine
      Enclosure Material Good A3 steel plate, cold rolled steel spray treatment
      Chamber material SUS304 thick 1mm mirror stainless steel
      Thermal Insulation Ultra thin fiberglass
      Door frame insulation Double-decked high and low temperature aging resistant silicone rubber door sealing strip
      Safety Devices Leakage, short circuit, over temperature, compression overVoltage, overload, overcurrent protection
      Power AC380V±10% 50HZ AC380V three-phase four-wire system + protective grounding N; Voltage allowable fluctuation range 10% V; Frequency allowable fluctuation range 50 +/- 0.5HZ; TN-S mode Power Supply or TT mode Power Supply; protective grounding resistance less than 4ΩLeakage protection, overload, short circuit and undercurrent protection
      Ambient Temperature 5~30℃
      Relative Humidity ≤85%R.H