![]() Model selection comparator
If you have any questions, please click below
|
![]() BenTing BGDW-100 Low Temperature Test Chamber
In coming
ChinaDetail
|
![]() HUDA QD-E708-1000K60-X5 Rapid temperature change Test Chamber
109170.0 RMB
ChinaDetail
|
|---|
| Type | constant temperature | alternating | |||
|---|---|---|---|---|---|
| Min-TEMP | -60℃ | -60℃ | |||
| Max-TEMP | 150℃ | ||||
| working Volume | ≤100L | 501~1000L | |||
| Temperature range | -60~0℃ | -60~150℃ | |||
|---|---|---|---|---|---|
| Humidity control range | 20~98%R.H | ||||
| Interior Volume | 100L | 1000L | |||
| Heating rate | 1~3℃/min | ||||
| Internal Dimensions of test chamber | 500 * 400 * 500Mm (width * depth * height) | ||||
| Temperature Fluctuation | ±0.5℃ | ±0.5℃ | |||
| Temperature Uniformity | ±1.5℃ | ≤2℃ | |||
| Heating rate | 1~3℃/min | ||||
| Cooling rate | 70.7~ 1.2 ℃/min, (non-linear no-load) | ||||
| Controller Accuracy range | Temperature +/- 0.1 ℃, Humidity +/- 0.1% R.H | ||||
| Temperature transducer | Platinum resistor PT100Ω | ||||
| Heating system | Nickel chromium alloy electric heating heater | Nickel alloy heating pipe, Circulating Fan, P.I.D control heating | |||
| Refrigeration system | Fully enclosed air-cooled single-stage compression refrigeration/original French "Taikang"/Fully enclosed air-cooled cascade compression refrigeration | Low temperature compressor imported from GermanyLow noise air-cooled chilled down water tower (optional) | |||
| Circulatory system | High temperature and low noise centrifugal motor, multi-blade centrifugal wind turbine | ||||
| Enclosure Material | Good A3 steel plate, cold rolled steel spray treatment | ||||
| Chamber material | SUS304 thick 1mm mirror stainless steel | ||||
| Thermal Insulation | Ultra thin fiberglass | ||||
| Door frame insulation | Double-decked high and low temperature aging resistant silicone rubber door sealing strip | ||||
| Safety Devices | Leakage, short circuit, over temperature, compression overVoltage, overload, overcurrent protection | ||||
| Power | AC380V±10% 50HZ | AC380V three-phase four-wire system + protective grounding N; Voltage allowable fluctuation range 10% V; Frequency allowable fluctuation range 50 +/- 0.5HZ; TN-S mode Power Supply or TT mode Power Supply; protective grounding resistance less than 4ΩLeakage protection, overload, short circuit and undercurrent protection | |||
| Ambient Temperature | 5~30℃ | ||||
| Relative Humidity | ≤85%R.H | ||||
Friendly reminder: This page is a comparison of BenTing BGDW-100,HUDA QD-E708-1000K60-X5.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about BenTing BGDW-100,HUDA QD-E708-1000K60-X5similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.