| Type | Benchtop | Portable | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F8mm | F8mm F11mm | |||
| Light source | LED light source | ||||
| Integrating sphere | > F40mm | ||||
| Color Repeatability | ≤0.02 | ≤0.02 | |||
| Aperture Shape | plane | plane | |||
| software | computer software | computer software | |||
| Special features | Fluorescence measurement | ||||
| Lighting method | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; includes UV/exclude UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; Haze (ASTM D1003) | ||||
|---|---|---|---|---|---|
| Integrating sphere size | Φ154mm | ||||
| Lighting source | 360~780Nm Combined LED Light source, 400nm Cut-off Light source, 420nm Cut-off Light source | ||||
| spectroscopy | Concave grating spectroscopy | ||||
| Sensor | 256 pixel dual array CMOS image sensor | ||||
| Wavelength Range | 360~780nm | ||||
| wavelength interval | 10nm | ||||
| Half bandwidth | 5nm | ||||
| Reflectance Measurement Range | 0~200% | ||||
| Measurement caliber | Reflection: Should 1mm Transmission: Should 8mm | Φ11mm/Φ8mm | |||
| Light-containing method | Reflection SCI/SCE, Transmission SCI/SCE | ||||
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | CIELabCh, CIELab, CIELCh, HunterLab, XYZ, CIELuv, CIE1960UCS, CIE1976UCS, yellowness index, light shade index, luminance factor, whiteness index, etc | |||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | ||||
| Other chroma metrics | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313),同色异谱指数Mt | ||||
| Viewing Angle | 2°/10° | ||||
| Available Light Sources | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | ||||
| display mode | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias | ||||
| Measurement time | Approximately 2.4s (approximately 5s for simultaneous SCI/SCE testing) | ||||
| Repeatability | Spectroscopic reflectance: 0019 1mm/SCI, standard deviation within 0.08% chromatic value: 0019 1mm/SCI, Delta E * ab within 0.15 (after instrument preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) | <0.02ΔE*ab 1) | |||
| Inter-instrument Agreement | ΔE*ab<0.25(SCI) | AVG 0.2 ΔE*ab 2) | |||
| size | 370*300*200mm | ||||
| Weight | About 9.6kg | ||||
| Power Supply | DC 24V, 3A power adapter Power | ||||
| Lighting source life | More than 3 million measurements in 5 years | ||||
| Display | TFT true color 7inch, capacitive touch screen | ||||
| Interface | USB, Bluetooth ® 5.0, print serial port | ||||
| store data | 5000 master standards, 40,000 samples (SCI/SCE counts as one data) | ||||
| Operating language | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) | ||||
| Operating temperature range | 0~40℃(32~104°F) | ||||
| Storage temperature range | -20~50℃(-4~122°F) | ||||
| Optional | Microprinters, instrument inverted test fixtures, culture dishes | ||||
| meet the standard | CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 | ||||
| Other chroma metrics 2 | Staining colour fastness, fastness to color change, force, coverage, APHA/Hazen/Pt-Co (platinum cobalt index), Gardner index 8 degree gloss, 555 shade classification, haze (ASTM D1003), Saybolt (Seibert index), ASTM D1500 color standard, Chinese Pharmacopoeia color standard | ||||
| Repeatability 2 | Spectral transmittance: 0019 8mm/SCI, standard deviation within 0.1% chromatic value: 0019 8mm/SCI, Delta E * ab within 0.18 (after instrument preheating correction, the average value of whiteboard 30 times at intervals of 5s measurement) | ||||