![]() Model selection comparator
If you have any questions, please click below
|
![]() AISRY ASR-50L-40 (paint plate) Programmable Constant Temperature & Humidity Test Chamber
In coming
ChinaDetail
|
![]() Factory NBC-50L-60 Programmable Constant Temperature & Humidity Test Chamber
16770.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -40℃ | -60℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤50L | ≤50L | |||
| TEMP fluctuation | ±0.5℃ ±1℃ | ±0.5℃ ±1℃ | |||
| Humidity deviation | |||||
| Interior size | 350*300*500mm | 350*300*500mm | |||
|---|---|---|---|---|---|
| Dimensions | 870*850*1370m | 870*850*1370m | |||
| Temperature range | -40~150℃ | -40~150℃ | |||
| temperature control Accuracy | ±0.1℃ | ||||
| Temperature fluctuation | ±0.5-1℃ | ||||
| Temperature Uniformity | ±1.5-2℃ | ±1.5-2℃ | |||
| Humidity control range | 20~98%R.H | 20~98%R.H | |||
| Humidity Control Accuracy | ±0.1℃ | ±0.1℃ | |||
| Humidity fluctuation | ±1-2%R.H | ||||
| Humidity Uniformity | ±1-3.0%R.H | ±1-3.0%R.H | |||
| Heating rate | 3 ℃/min nonlinear no-load | 3 ℃/min nonlinear no-load | |||
| Cooling rate | 1 ℃/min (no-load nonlinear) | 1 ℃/min (no-load nonlinear) | |||
| Total Weight | 130KG | 130KG | |||
| Use Voltage | 220V/50HZ | ||||
| Permissible Voltage Variation | ±10% | ±10% | |||
| Maximum power | 5kw | ||||
| Inner box material | Mirror Stainless Steel Plate (SUS #304) | Mirror stainless steel plate (SUS #304) | |||
| Enclosure Material | Painted panel | Mirror stainless steel plate (SUS #304) | |||
| Top opening | Laser cutting and opening according to the test sample drawings provided by the customer | ||||
| Thermal insulation material | Bayer Polyurethane Rigid Foam + High Density Glass Fiber | ||||
| Shelf | 1 layer (punching treatment of high-strength SUS304 #stainless steel plate) | 1 layer (punching treatment of high-strength SUS304 #stainless steel plate) | |||
| Maximum number of shelves | 4 layers (shelf spacing is adjustable) | 4 layers (shelf spacing is adjustable) | |||
| Shelf Weight | 20KG | 20KG | |||
| Test chamber door | Single door, double door, open left | Single door, double-decked door, left opening | |||
| test hole | Open a 50mm diameter test hole on the left, the durability, parcel and the protection of the wiring harness far exceed that of domestic ordinary materials | A 50mm diameter test hole is opened on the left, and the durability, parcel and protection of the wiring harness far exceed that of domestic ordinary materials | |||
| Display | Imported 7-inch color touch screen display (touch screen operation control) | Imported 7-inch color touch screen display (touch screen operation control) | |||
| temperature resolution | ±0.1℃ | ||||
| Humidity resolution | ±0.1%R.H | ±0.1%R.H | |||
| temperature Control system | 9 groups of P.I.D control parameter setting, P.I.D automatic calculation | ||||
| Environment temperature | 0~30℃ | ||||
| Specification Environment | 5~25℃ | 5~25℃ | |||
| Operating Environment Requirements | Miscellaneous items should not be placed within 60CM around the instrument, and the installation ground should not be severely inclined | ||||
Friendly reminder: This page is a comparison of AISRY ASR-50L-40 (paint plate),Factory NBC-50L-60.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about AISRY ASR-50L-40 (paint plate),Factory NBC-50L-60similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.