![]() HUDA QT-E702-100B60 Programmable Humidity Chamber
16600.0 RMB
ChinaDetail
|
![]() HUDA QT-E702-100K60 Programmable Humidity Chamber
16600.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -60℃ | -60℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤100L | ≤100L | |||
| TEMP fluctuation | ±0.5℃ | ±0.5℃ | |||
| Humidity deviation | ±2% | ±2% | |||
| Interior Volume | 100L | 100L | |||
|---|---|---|---|---|---|
| Temperature range | -60~150℃ | -60~150℃ | |||
| Temperature Resolution | 0.01℃ | 0.01℃ | |||
| Temperature Fluctuation | ≤±0.5℃ | ≤±0.5℃ | |||
| Temperature Uniformity | ±2℃ | ±2℃ | |||
| Humidity control range | 20~98%R.H | 20~98%R.H | |||
| Humidity Deviation | ±2%R.H | ±2%R.H | |||
| Input Power | |||||
| Operating Environment | |||||
| Working time | |||||
| Power | 220V | 220V | |||
| Interior size | 400*500*500mm | 400*500*500mm | |||
| Dimensions | 940mm×1400mm×1080mm | 680mm×1430mm×1420mm | |||
| Shelf (std.) | |||||
| Temperature deviation | ≤±2℃ | ≤±2℃ | |||
| Humidity resolution | 0.1%R.H | ||||
| Temperature control Accuracy | ±0.01℃ | ±0.01℃ | |||
| Humidity Control Accuracy | ±0.1%RH | ±0.1%RH | |||
| Heating rate | ≧3℃/min | ≧3℃/min | |||
| Cooling time | ≧1℃/min | ≧1℃/min | |||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorMechanical binary refrigeration method | 2 * 0.75HP imported French Taikang fully enclosed compressorMechanical binary refrigeration method | |||
| refrigerant | Environmentally friendly refrigerant R404 | Environmentally friendly refrigerant R404/R23/freezing oil | |||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorMechanical binary refrigeration method | 2 * 0.75HP imported French Taikang fully enclosed compressorMechanical binary refrigeration method | |||
| Circulation | 离心风机带强制循环 | ||||
| Condenser | finned tube heat exchangerStainless steel brazed plate heat exchanger | finned tube heat exchangerStainless steel brazed plate heat exchanger | |||
| Condensation method | air cooling | air cooling | |||
| Condenser | finned tube heat exchangerStainless steel brazed plate heat exchanger | finned tube heat exchangerStainless steel brazed plate heat exchanger | |||
| Humidification system | Stainless steel humidifier | Stainless steel humidifier | |||
| Heating system | Nickel chromium alloy stainless steel heating device | Nickel chromium alloy stainless steel heating device | |||
| Water supply system | Front-mounted water supply tank, fully automatic water supply system | Front-mounted water supply tank, fully automatic water supply system | |||
| Controller | Taiwan, China Youyi Controller | Taiwan, China Youyi Controller | |||
| Setup method | Chinese/English interface, touch input | Chinese/English interface, touch input | |||
| Operation mode | Program method/fixed value method | Program method/fixed value method | |||
| Set range | Maximum Temperature range 5 ℃ | Maximum Temperature range 5 ℃ | |||
| Display resolution | Temperature: 0.01 ℃; Time: 0.1min | Temperature: 0.01 ℃; Time: 0.1min | |||
| Power-off memory function | The power failure recovery mode can be set as: hot start/cold start/stop | The power failure recovery mode can be set as: hot start/cold start/stop | |||
| input | Platinum resistance | Platinum resistance | |||
| Storage function | Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand the storage Capacity | Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand the storage Capacity | |||
| Safety Devices | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc | |||
| Software Operating Environment | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | |||
| Enclosure Material | SUS304 #stainless steel plate (1.0mm thick) | Cold rolled steel plate (1.0mm thick) | |||
| Inner box material | SUS304 #stainless steel plate (1.0mm thick) | SUS304 #stainless steel plate (1.0mm thick) | |||
| Thermal insulation material | 100mm polyurethane rigid foam + 100mm high density fiberglass cotton | 100mm polyurethane rigid foam + 100mm high density fiberglass cotton | |||
| Weight | 209kg | ||||
| Rated current | 11A | 11A | |||
| Rated power | 6.5kw | 6.5kw | |||
| Power | 220V | 220V | |||
| Test hole diameter | 50mm | 50mm | |||
| program amount | Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments | Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments | |||
| Communication interface | 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system | 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system | |||