![]() HUDA QT-E702-150B40 Programmable Humidity Chamber
16230.0 RMB
ChinaDetail
|
![]() kesionots KS-HW150D(150℃) humidity chamber
34200.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -40℃ | -40℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤150L | ≤150L | |||
| TEMP fluctuation | ±0.5℃ | ±0.5℃ | |||
| Humidity deviation | ±2% | ±2.5% | |||
| Interior Volume | 150L | 150L | |||
|---|---|---|---|---|---|
| Temperature range | -40~150℃ | -40~150℃ | |||
| Temperature Resolution | 0.01℃ | ±0.1℃ | |||
| Temperature Fluctuation | ≤±0.5℃ | ||||
| Temperature Uniformity | ±2℃ | ±1℃ | |||
| Humidity control range | 20~98%R.H | 20~98%R.H. | |||
| Humidity Deviation | ±2%R.H | ||||
| Input Power | |||||
| Operating Environment | |||||
| Working time | |||||
| Power | 220V | 220V AC (+/- 10%), protective ground wire, ground resistance ≤ 4Ω; | |||
| Interior size | 500*600*500mm | 500*600*500mm | |||
| Dimensions | 1040mm×1500mm×1080mm | 1000*1460*1040mm | |||
| Shelf (std.) | |||||
| Temperature deviation | ≤±2℃ | ||||
| Humidity resolution | 0.1%R.H | ±0.1%R.H | |||
| Temperature control Accuracy | ±0.01℃ | ±1.0℃ | |||
| Humidity Control Accuracy | ±0.1%RH | ±2.0%R.H. | |||
| Heating rate | ≧3℃/min | ≈4.0℃/min | |||
| Cooling time | ≧1℃/min | ||||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorSingle stage refrigeration | ||||
| refrigerant | Environmentally friendly refrigerant R404 | ||||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorSingle stage refrigeration | ||||
| Wind circulation | Centrifugal fan with forced circulation | ||||
| Condenser | finned tube heat exchangerAir-cooled scale condenser, chilled down fan | ||||
| Condensation method | air cooling | ||||
| Condenser | finned tube heat exchangerAir-cooled scale condenser, chilled down fan | ||||
| Humidification system | Stainless steel humidifier | ||||
| Heating system | Nickel chromium alloy stainless steel heating device | ||||
| Water supply system | Front-mounted water supply tank, fully automatic water supply system | ||||
| Controller | Taiwan, China Youyi Controller | Korean "TEMI" "TH-900C" or Japanese "OYO" card to choose | |||
| Setup method | Chinese/English interface, touch input | ||||
| Operation mode | Program method/fixed value method | ||||
| Set range | Maximum Temperature range 5 ℃ | ||||
| Display resolution | Temperature: 0.01 ℃; Time: 0.1min | ||||
| Power-off memory function | The power failure recovery mode can be set as: hot start/cold start/stop | ||||
| input | Platinum resistance | ||||
| Storage function | Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand the storage Capacity | ||||
| Safety Devices | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc | Air burn prevention, high Voltage protection, overheating protection, overcurrent protection, Pottery and porcelain E-16 fast fuse, no fuse overload protection | |||
| Software Operating Environment | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | ||||
| Enclosure Material | SUS304 #stainless steel plate (1.0mm thick) | ||||
| Inner box material | SUS304 #stainless steel plate (1.0mm thick) | ||||
| Thermal insulation material | 100mm polyurethane rigid foam + 100mm high density fiberglass cotton | High temperature resistant high density formic acid vinegar foam insulator material | |||
| Weight | 251kg | ||||
| Rated current | 8.5A | ||||
| Rated power | 5.5kw | ||||
| Power | 220V | 220V AC (+/- 10%), protective ground wire, ground resistance ≤ 4Ω; | |||
| Test hole diameter | 50mm | ||||
| program amount | Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments | ||||
| Communication interface | 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system | RS-232 standard communication interface device, which can be connected to a personal computer (PC) at the same time for multi-machine control and management | |||
Friendly reminder: This page is a comparison of HUDA QT-E702-150B40,kesionots KS-HW150D(150℃).NBCLab only provides you with the similarities and differences of the product in the model and specifications.