      HUDA QT-E702-100K60 Programmable Humidity Chamber
      16600.0 RMB
      ChinaChina
      Detail
      JiangKai NBC-HW-80(-60℃) Humidity chamber
      In coming
      ChinaChina
      Detail
      Model comparison
      Min-TEMP -60℃ -60℃
      Max-TEMP >100℃ >100℃
      Min-RH ≤20%RH ≤20%RH
      Max-humidity 98% RH 98% RH
      Volume ≤100L ≤100L
      TEMP fluctuation ±0.5℃ ±0.5℃
      Humidity deviation ±2% ±3%
      Parameter comparison
      Interior Volume 100L 80L
      Temperature range -60~150℃ -60℃~150℃
      Temperature Resolution 0.01℃
      Temperature Fluctuation ≤±0.5℃
      Temperature Uniformity ±2℃
      Humidity control range 20~98%R.H 20%~98%R.H.
      Humidity Deviation ±2%R.H ≤3%
      Humidity stability ±2%R.H
      Humidity Uniformity ±3%R.H
      Working time
      Power 220V
      Interior size 400*500*500mm 400*500*400mm
      Dimensions 680mm×1430mm×1420mm
      Shelf (std.)
      Temperature deviation ≤±2℃ ≤2℃
      湿度Resolution 0.1%R.H
      Temperature control Accuracy ±0.01℃
      Humidity Control Accuracy ±0.1%RH
      Heating rate ≧3℃/min
      Cooling time ≧1℃/min From room temperature to -60 ℃ for about 60 minutes (no-load nonlinear)
      Refrigeration system 2 * 0.75HP imported French Taikang fully enclosed compressorMechanical binary refrigeration method
      refrigerant Environmentally friendly refrigerant R404/R23/freezing oil Environmentally friendly refrigerant R404A
      Refrigeration system 2 * 0.75HP imported French Taikang fully enclosed compressorMechanical binary refrigeration method
      Wind circulation Centrifugal fan with forced circulation
      Condenser finned tube heat exchangerStainless steel brazed plate heat exchanger Fin type with cooling motor
      Condensation method air cooling
      Condenser finned tube heat exchangerStainless steel brazed plate heat exchanger Fin type with cooling motor
      Humidification system Stainless steel humidifier
      Heating system Nickel chromium alloy stainless steel heating device
      Water supply system Front-mounted water supply tank, fully automatic water supply system
      Controller Taiwan, China Youyi Controller
      Setup method Chinese/English interface, touch input
      Operation mode Program method/fixed value method
      Set range Maximum Temperature range 5 ℃
      Display resolution Temperature: 0.01 ℃; Time: 0.1min
      Power-off memory function The power failure recovery mode can be set as: hot start/cold start/stop
      input Platinum resistance
      Storage function Standard 2G SD card recording test data Linear dispersion, can upload and download data, can expand the storage Capacity
      Safety Devices Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc
      Software Operating Environment IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system
      Enclosure Material Cold rolled steel plate (1.0mm thick) Stainless steel plate atomized (SUS #304) or cold plate paint (optional)
      Inner box material SUS304 #stainless steel plate (1.0mm thick) Stainless Steel Plate (SUS #304)
      Thermal insulation material 100mm polyurethane rigid foam + 100mm high density fiberglass cotton Rigid Polyurethane Foam and Glass Cotton
      重量 198kg
      Rated current 11A
      Rated power 6.5kw
      Power 220V
      Test hole diameter 50mm
      program amount Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments
      Communication interface 1. R232/485 communication 2. Can display Linear dispersion, data acquisition 3. Can be used as monitoring and remote Control system

      Friendly reminder: This page is a comparison of HUDA QT-E702-100K60,JiangKai NBC-HW-80(-60℃).NBCLab only provides you with the similarities and differences of the product in the model and specifications.

      For more information about HUDA QT-E702-100K60,JiangKai NBC-HW-80(-60℃)similarities and differences, please refer to the NBCLab product details.

      Focus on online sales of Lab Testing Instruments