| Min-TEMP | -40℃ | -40℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤150L | ≤150L | |||
| TEMP fluctuation | ±0.5℃ | ±0.5℃ ±1℃ | |||
| Humidity deviation | ±2% | ±1% ±1.5% ±2% | |||
| Studio Volume | 150L | 150L | |||
|---|---|---|---|---|---|
| Temperature range | -40~150℃ | -40~150℃ | |||
| Temperature Resolution | 0.01℃ | ||||
| Temperature fluctuation | ≤±0.5℃ | ||||
| Temperature Uniformity | ±2℃ | ±1.5-2℃ | |||
| Humidity Control Range | 20~98%R.H | 20~98%R.H | |||
| Humidity Deviation | ±2%R.H | ±1~2% | |||
| humidity fluctuation | ±2%R.H | ||||
| Humidity Uniformity | ±3%R.H | ±1-3.0%R.H | |||
| Continuous Operating Time | |||||
| Power Supply | 220V | ||||
| Interior size | 500*600*500mm | 500*500*600mm | |||
| Dimensions | 780*1540*1420mm | ||||
| Shelf (std.) | |||||
| Temperature deviation | ≤±2℃ | ||||
| Humidity resolution | 0.1%R.H | ||||
| Temperature control Accuracy | ±0.01℃ | ||||
| Humidity Control Accuracy | ±0.1%R.H | ||||
| Heating rate | ≧3℃/min | 3 ℃/min nonlinear no-load | |||
| Cooling rate | ≧1℃/min | 1 ℃/min (no-load nonlinear) | |||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorSingle stage refrigeration | ||||
| refrigerant | Environmentally friendly refrigerant R404 | ||||
| Refrigeration system | 1 imported French Taikang fully enclosed compressorSingle stage refrigeration | ||||
| Air circulation mode | Centrifugal fan with forced circulation | ||||
| condenser | finned tube heat exchangerAir-cooled scale condenser, chilled down fan | ||||
| Condensation method | air cooling | ||||
| condenser | finned tube heat exchangerAir-cooled scale condenser, chilled down fan | ||||
| Humidification system | Stainless steel humidifier | ||||
| Heating system | Nickel chromium alloy stainless steel heater | ||||
| water supply system | Front-mounted water supply tank, fully automatic water supply system | ||||
| Controller | Taiwan Youyi Controller | ||||
| setting method | Chinese/English interface, touch input | ||||
| operation mode | Program method/valuation method | ||||
| setting range | Maximum temperature range Upper/Lower limit 5 ℃ | ||||
| Display resolution | Temperature: 0.01 ℃; Time: 0.1 min | ||||
| Power-off memory function | The power failure recovery mode can be set as: hot start/cold start/stop | ||||
| input | platinum resistance | ||||
| storage function | Standard 2G SD card record test data Linear dispersion, can upload and download data, can expand storage | ||||
| Safety Devices | Overall equipment overtemperature, fan overheating protection, overall equipment underphase/reverse phase, refrigeration system overload, refrigeration unit overpressure, overall equipment Timer, leakage, operation instructions, automatic shutdown after fault alarm, etc | ||||
| Software Operating Environment | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | ||||
| Enclosure Material | Cold rolled steel plate (1.0mm thick) | Mirror stainless steel plate (SUS #304) | |||
| Inner chamber material | SUS #304 mirror stainless steel (1mm thick) | ||||
| Insulation material | 100Mm polyurethane rigid foam + 100mm high density fiberglass cotton | ||||
| Weight | 239kg | ≈185KG | |||
| Rated current | 8.5A | ||||
| rated power | 5.5kw | ||||
| Power Supply | 220V | ||||
| test hole | 50mm | ||||
| program Volume | Maximum 120 groups, 1 program can be combined from 1 to 99 segments, Capacity: 1200 segments | ||||
| communication interface | 1. R232/485 communication 2. Linear dispersion can be displayed, data acquisition 3. Can be used as monitoring and remote Control system | ||||