![]() Model selection comparator
If you have any questions, please click below
|
![]() HUDA QD-E703-100K55 Thermal Shock Test Chamber
96350.0 RMB
ChinaDetail
|
![]() Factory NBC-80B Thermal Shock Test Chamber
95000.0 RMB
ChinaDetail
|
|---|
| standard | Cabinet | Cabinet | |||
|---|---|---|---|---|---|
| Cooling method | Air-Cooled | Air-Cooled | |||
| Number of cabins | Two-Chamber | Two-Chamber | |||
| With humidity function | without | without | |||
| Volume | ≤100L | ≤100L | |||
| Temperature range | -55℃~+150℃ | ||||
|---|---|---|---|---|---|
| Temperature Fluctuation | ±0.5℃ | ±2℃ | |||
| Temperature deviation | |||||
| Heating rate | |||||
| Cooling rate | From room temperature~ -55 ℃ ≤ 60min | ||||
| Heating device | |||||
| Temperature control method | |||||
| Power | The power cord is 3-phase 5-wire 30A, 380V, 50HZ, Wire diameter 4 square, grounding 2.5 square15KW | About 18KW | |||
| Weight | About 550kg | ||||
| Standards | |||||
| Internal Dimensions | |||||
| External Dimensions | |||||
| High Temperature Impact Range | +60℃~+150℃+60℃~+170℃ | ||||
| Low Temperature Impact Range | -55~-10℃-10~-70℃ | ||||
| High Temperature Impact Range | +60℃~+150℃+60℃~+170℃ | ||||
| Low Temperature Impact Range | -55~-10℃-10~-70℃ | ||||
| Impact thermostatic time | 30 minutes each | ||||
| According to measurement specifications | Measure the SENSOR placement point, 1/10 of the inner size of the inner box wall | ||||
| Dimensions | 1455*1790*1980mm | ||||
| Basket size | 400*500*500mm(W*H*D) | ||||
| Inner Volume | 100L | ||||
| Heating time | RT+25°C→170°C≈35min | ||||
| Preparatory cooling time | RT+25°C→-70°C≈55min | ||||
| temperature residence time | 30 minutes each for high and low temperatures (min) | ||||
| Impact Recovery Time | -55℃~+150℃ | ||||
| Mobile transition time | ≤ 10 seconds, stable within 3-5 minutes | ||||
| Test tank conversion travel time | ≦10S | ||||
| Test method | During the test, the object to be tested moves and switches between the high temperature tank and the low temperature tank to achieve the purpose of heat & cold shock test | ||||
| Weight | About 550kg | ||||
| Allowable Voltage fluctuation range | 10% | ||||
| Allowable Frequency Range | 50±1Hz | ||||
| Operating Conditions | Ambient Temperature is 0~ + 35 ℃, Relative Humidity < 85% | ||||
| Analytical Accuracy | 0.1℃ | ||||
| Time Accuracy | 0.1min | ||||
| Temperature Fluctuation | ±0.5℃ | ±2℃ | |||
| distribution uniformity | ±2.0℃ | ||||
| Air conditioning channel | Built-in high temperature zone, low temperature zone air valve, loop air duct and stainless steel loop fan, by switching the basket, the test product is sent to the heat and cooling space; so as to achieve rapid temperature alternation and uniform indoor temperature distribution | ||||
| Low temperature zone mechanical room | Evaporator, loop fan, cold storage sheet, heating device, loop wind wheel, volute | ||||
| High temperature zone machinery room | Heating device, loop fan, pressure equilibrate, loop wheel, volute | ||||
| Distribution control cabinet | Total power circuit breaker, Controller, switchboard, cooling fan, over-temperature protector, cylinder, pressure protector, liquid storage tank, air-cooled condenser, refrigeration unit | ||||
| Heating system | Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrateImported nickel-chromium alloy electric heating deviceFully independent system, efficient bare wire heating | ||||
| Refrigeration system | Adopt water-cooled heat exchangerAir-cooled finnedGerman import blog low temperature compression2 sets imported from France TaikangAir-cooled with cooling motor | ||||
| chiller | Water circulation cooling use | ||||
| Test material rack | Stainless steel SUS #304 punching rack 2 pieces (load-bearing 20kg) adjustable spacing | ||||
| Operating Mode | The cold zone, the hot zone, and the two boxes are matched by moving the test product, the low temperature tank is connected with the test chamber, and the basket is instantly introduced into the low temperature test chamber; when the impact is high temperature, the basket is instantly introduced into the high temperature test chamber. | ||||
| input | Thermocouple | ||||
| centrifugal fan | Low noise multi-wing centrifugal fan | ||||
| Heating system | Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrateImported nickel-chromium alloy electric heating deviceFully independent system, efficient bare wire heating | ||||
| Heating Control mode | Equiperiodic pulse without touchpoint (solid state relay) | ||||
| Control mode | Anti-integral saturation PID, BTC equilibrate temperature control mode (temperature test equipment)Adopt touch programmable temperature Controller | ||||
| subsidiary function | Fault alarm and cause, processing prompt function, power failure protection function, Upper/Lower limit temperature protection function, self-diagnosis function, automatic stop function | ||||
| Software Operating Environment | IBM PC compatible machine, CPU above PH, memory above 128M, Simplified Chinese windows2000 or Simplified Chinese windowsXP, win7 systemData analysis software | ||||
| Software Operating Environment | IBM PC compatible machine, CPU above PH, memory above 128M, Simplified Chinese windows2000 or Simplified Chinese windowsXP, win7 systemData analysis software | ||||
| Temperature measurement | T Thermocouple | Pt100 platinum resistor | |||
| Refrigeration system | Adopt water-cooled heat exchangerAir-cooled finnedGerman import blog low temperature compression2 sets imported from France TaikangAir-cooled with cooling motor | ||||
| Refrigeration system | Adopt water-cooled heat exchangerAir-cooled finnedGerman import blog low temperature compression2 sets imported from France TaikangAir-cooled with cooling motor | ||||
| Evaporator | finned tube heat exchangerFin type multi-stage automatic load Capacity adjustmentFin type multi-stage automatic load Capacity adjustment | ||||
| Evaporative condenser | The plate heat exchanger using high temperature copper fiber welding has small surface area, small energy loss and high heat exchange efficiency | ||||
| Throttle device | Thermal expansion valve, capillary tubing | ||||
| Number of programs available | Maximum 120 groups, connection can be set between programs | ||||
| RS-232 Communication interface | Linear dispersion display, data collection, can be used as monitoring and remote Control system | ||||
| Operation mode | Program loop mode | ||||
| Display resolution | Temperature: 0.1 ℃; Time: 0.1min | ||||
| display | 5.7 LCD color display | ||||
| refrigerant | Environmentally friendly refrigerant R404A/R23Environmentally friendly refrigerant | ||||
| Refrigeration system protection device | Compressor overheating, compressor overcurrent, compressor overpressure, condensing fan overheating | ||||
| Protection device | Adjustable over-temperature protection, air conditioning channel limit over-temperature, fan, motor overheating relayTotal Power phase sequence and phase loss protection, leakage protection, overload and short circuit protection, Ambient Temperature protectionOvercurrent protection switch; line fuse; over temperature protection switch; compressor and motor overload protection switch; refrigerant high Voltage protection switch | Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, underphase, power failure standby and other alarm warnings. | |||
| Protection device | Adjustable over-temperature protection, air conditioning channel limit over-temperature, fan, motor overheating relayTotal Power phase sequence and phase loss protection, leakage protection, overload and short circuit protection, Ambient Temperature protectionOvercurrent protection switch; line fuse; over temperature protection switch; compressor and motor overload protection switch; refrigerant high Voltage protection switch | Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, underphase, power failure standby and other alarm warnings. | |||
| Environmental conditions | Ambient Temperature should be kept within 0 ℃~ +/- 35 ℃, relative temperature: ≤ 85% | ||||
| Wind path mechanism | Pneumatic cylinder actuation mechanism | ||||
| Control mode | Anti-integral saturation PID, BTC equilibrate temperature control mode (temperature test equipment)Adopt touch programmable temperature Controller | ||||
| Protection device | Adjustable over-temperature protection, air conditioning channel limit over-temperature, fan, motor overheating relayTotal Power phase sequence and phase loss protection, leakage protection, overload and short circuit protection, Ambient Temperature protectionOvercurrent protection switch; line fuse; over temperature protection switch; compressor and motor overload protection switch; refrigerant high Voltage protection switch | Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, underphase, power failure standby and other alarm warnings. | |||
| Accessories | 2 compartment racks | ||||
| Power | The power cord is 3-phase 5-wire 30A, 380V, 50HZ, Wire diameter 4 square, grounding 2.5 square15KW | About 18KW | |||
| Power | The power cord is 3-phase 5-wire 30A, 380V, 50HZ, Wire diameter 4 square, grounding 2.5 square15KW | About 18KW | |||
| Liner material | Stainless Steel Plate (SUS #304) | ||||
| Enclosure Material | Cold Rolled Steel Electrostatic Spray Paint (CR) | ||||
| test hole | 1 50mm hole at the top of the body is attached with 1 stainless steel hole cover and 1 silicone plug. | ||||
| Thermal insulation material | High temperature tank: 24k Glass cotton; Low temperature tank: High density PU foam + Glass cotton | ||||
| Box door | Panel door, left open; a. Flat recessed handle; b. Concealed hinge | ||||
| Sealing device | Silicone foam pressing | ||||
| Sample placement rack | A. Stainless steel SUS #304 mesh storage tray 2 pieces; b. Stainless steel adjustable spacing shelf hanging hook type 8 pieces | ||||
| Air supply circulation, drainage system | A. 4 motors; b. Stainless steel elongated shaft; c. SIROCCO FAN; d. Drainage system | ||||
| Heating system | Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrateImported nickel-chromium alloy electric heating deviceFully independent system, efficient bare wire heating | ||||
| Refrigeration system | Adopt water-cooled heat exchangerAir-cooled finnedGerman import blog low temperature compression2 sets imported from France TaikangAir-cooled with cooling motor | ||||
| refrigerant | Environmentally friendly refrigerant R404A/R23Environmentally friendly refrigerant | ||||
| Refrigeration system | Adopt water-cooled heat exchangerAir-cooled finnedGerman import blog low temperature compression2 sets imported from France TaikangAir-cooled with cooling motor | ||||
| Evaporator | finned tube heat exchangerFin type multi-stage automatic load Capacity adjustmentFin type multi-stage automatic load Capacity adjustment | ||||
| expansion system | Danfoss expansion valve | ||||
| Evaporator | finned tube heat exchangerFin type multi-stage automatic load Capacity adjustmentFin type multi-stage automatic load Capacity adjustment | ||||
Friendly reminder: This page is a comparison of HUDA QD-E703-100K55,Factory NBC-80B.NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about HUDA QD-E703-100K55,Factory NBC-80Bsimilarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.