![]() Model selection comparator
If you have any questions, please click below
|
![]() HUDA QD-E705-12m³(-60℃) Constant temperature and Humidity Test Chamber
269430.0 RMB
ChinaDetail
|
![]() HUDA QD-E705-20m³(-60℃) Humidity Chamber
320700.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -60℃ | -60℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | ≤100℃ | ≤100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤800L | ≤800L | |||
| TEMP fluctuation | ±0.5℃ | ±0.5℃ | |||
| Humidity deviation | ±2% | ±2% | |||
| Inner size | 12M ³ (Miscellaneous size can be customized) | 20M ³ (Miscellaneous size can be customized) | |||
|---|---|---|---|---|---|
| Temperature range | -60~80℃ | -60~80℃ | |||
| Specimen limitation | This test equipment prohibits the testing of flammable, explosive and volatile matter samples; the testing of storing corrosive substance samples, the testing of storing organisms, the testing and storage of strong electromagnetic emission source samples | This test equipment prohibits the testing of flammable, explosive and volatile matter samples; the testing of storing corrosive substance samples, the testing of storing organisms, the testing and storage of strong electromagnetic emission source samples | |||
| Power supply conditions | The user is required to configure the air or power switch of the corresponding Capacity for the equipment at the installation site, and the switch must independently control the use of the equipment | The user is required to configure the air or power switch of the corresponding Capacity for the equipment at the installation site, and the switch must independently control the use of the equipment | |||
| Permissible Voltage Variation | 10% | 10% | |||
| Frequency | 50±0.5Hz | 50±0.5Hz | |||
| Protective ground resistance | Less than 4Ω | Less than 4Ω | |||
| Functional requirements | 1. (air) indoor space cooling, heating, humidification, dehumidification; 2. According to the temperature and Humidity setting, the indoor space reaches the set temperature and Humidity | 1. (air) indoor space cooling, heating, humidification, dehumidification; 2. According to the temperature and Humidity setting, the indoor space reaches the set temperature and Humidity | |||
| Test environmental conditions | Ambient Temperature is + 25 ℃, Relative Humidity ≤ 85%, the test chamber without sample conditions measured. | Ambient Temperature is + 25 ℃, Relative Humidity ≤ 85%, the test chamber without sample conditions measured. | |||
| Humidity control range | 20~98%H.R | 20~98%H.R | |||
| Temperature Resolution | 0.01℃ | 0.01℃ | |||
| Heating rate | 25→80℃≤35min | 25→80℃≤35min | |||
| Laboratory structure | Combined assembly board, detachable structure, convenient for on-site installation. | Combined assembly board, detachable structure, convenient for on-site installation. | |||
| Enclosure Material | Color plate φ = 0.8mm | Color plate φ = 0.8mm | |||
| Inner box material | Stainless steel plate SUS304 φ = 0.8mm | Stainless steel plate SUS304 φ = 0.8mm | |||
| Thermal insulation material | 100mm insulation material is rigid polyurethane foam | 100mm insulation material is rigid polyurethane foam | |||
| Baseplate load | The baseplate is strengthened, and the load can be 600kg/㎡ (evenly distributed load) | The baseplate is strengthened, and the load can be 600kg/㎡ (evenly distributed load) | |||
| Material of door | Same warehouse board | Same warehouse board | |||
| Film thickness of the door | 100mm insulation material is rigid polyurethane foam | 100mm insulation material is rigid polyurethane foam | |||
| Door | Double door, effective headroom size W1500 * H2200mm, | Double door, effective headroom size W1500 * H2200mm, | |||
| Door lock | Japanese door lock, strong door hinge, with anti-deadlock device | Japanese door lock, strong door hinge, with anti-deadlock device | |||
| Viewing Window | 2 Viewing Windows: There are 2 W300 * H450mm conductive film explosion-proof and fog-proof tempered Glass Viewing Windows on the door. | 2 Viewing Windows: There are 2 W300 * H450mm conductive film explosion-proof and fog-proof tempered Glass Viewing Windows on the door. | |||
| test hole | 1 test hole, size: Φ100mm, the position is to be determined by the customer | 1 test hole, size: Φ100mm, the position is to be determined by the customer | |||
| Controller | TEMI2700 LCD touch programmable Control system imported from Korea; lighting switch, main power switch, RS-232 communication interfaceImported Controller, control temperature and Humidity respectively; South Korea SAMWON, color touch screen control TEMI2700 | TEMI2700 LCD touch programmable Control system imported from Korea; lighting switch, main power switch, RS-232 communication interfaceImported Controller, control temperature and Humidity respectively; South Korea SAMWON, color touch screen control TEMI2700 | |||
| Machinery room | Refrigeration unit, exhaust fan, drainage device, water vapor outlet | Refrigeration unit, exhaust fan, drainage device, water vapor outlet | |||
| Distribution control cabinet | Total power circuit breaker, Controller, switchboard, cooling fan, over-temperature protector | Total power circuit breaker, Controller, switchboard, cooling fan, over-temperature protector | |||
| Heating system | Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrate | Using scale heat dissipation heating pipe P.I.D to control heating to achieve temperature equilibrate | |||
| Chill down the system | Heat exchanger: water-cooled condenser | Heat exchanger: water-cooled condenser | |||
| Mode of transportation | The mechanical room is transported as a whole, and the spare parts of the warehouse are packaged and transported. | The mechanical room is transported as a whole, and the spare parts of the warehouse are packaged and transported. | |||
| Controller | TEMI2700 LCD touch programmable Control system imported from Korea; lighting switch, main power switch, RS-232 communication interfaceImported Controller, control temperature and Humidity respectively; South Korea SAMWON, color touch screen control TEMI2700 | TEMI2700 LCD touch programmable Control system imported from Korea; lighting switch, main power switch, RS-232 communication interfaceImported Controller, control temperature and Humidity respectively; South Korea SAMWON, color touch screen control TEMI2700 | |||
| RS-232 communication interface | Can be connected to a computer to display Linear dispersion, data acquisition; can be used as a monitoring and remote Control system; can be synchronized with multiple machines | Can be connected to a computer to display Linear dispersion, data acquisition; can be used as a monitoring and remote Control system; can be synchronized with multiple machines | |||
| SD memory card | Used to store test data and test Linear dispersion, the standard storage Capacity is 2G, which can be expanded to 4G | Used to store test data and test Linear dispersion, the standard storage Capacity is 2G, which can be expanded to 4G | |||
| Setup method | Chinese/English interface, touch input | Chinese/English interface, touch input | |||
| Operation mode | Program method/fixed value method | Program method/fixed value method | |||
| Set range | Maximum Temperature range 5 ℃Temperature: Adjust according to the temperature working interval of the equipment (upper limit + 5 ℃, lower limit -5 ℃) | Maximum Temperature range 5 ℃Temperature: Adjust according to the temperature working interval of the equipment (upper limit + 5 ℃, lower limit -5 ℃) | |||
| Display resolution | Temperature: 0.01 ℃; Humidity: 0.1%; Time: 1min | Temperature: 0.01 ℃; Humidity: 0.1%; Time: 1min | |||
| Power-off memory | 可设定断电恢复模式为:热起/冷起/停止 | ||||
| Boot appointment | 可随意设定开机时间,打开电源后时间到机台自动运行 | ||||
| Temperature transducer | PT100 platinum resistor | PT100 platinum resistor | |||
| Curve recording | With battery-protected RAM, it can save the setting value, sampling value and sampling time of the device; the maximum recording time is 60 days (when the sampling period is 1.5min) | With battery-protected RAM, it can save the setting value, sampling value and sampling time of the device; the maximum recording time is 60 days (when the sampling period is 1.5min) | |||
| Software Operating Environment | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000 or Simplified Chinese WindowsXP operating system | |||
| Network connection | It can be connected to the Ethernet through professional software, remote control and remote assistance can be done through the network, and test data can be collected through the network, and multiple machines can be controlled at the same time | It can be connected to the Ethernet through professional software, remote control and remote assistance can be done through the network, and test data can be collected through the network, and multiple machines can be controlled at the same time | |||
| Set range | Maximum Temperature range 5 ℃Temperature: Adjust according to the temperature working interval of the equipment (upper limit + 5 ℃, lower limit -5 ℃) | Maximum Temperature range 5 ℃Temperature: Adjust according to the temperature working interval of the equipment (upper limit + 5 ℃, lower limit -5 ℃) | |||
| input | Platinum resistance/DC 1~ 5V input | Platinum resistance/DC 1~ 5V input | |||
| Additional features | Fault alarm and cause, processing prompt function, power-off protection function, Upper/Lower limit temperature protection function | Fault alarm and cause, processing prompt function, power-off protection function, Upper/Lower limit temperature protection function | |||
| Refrigeration system | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | |||
| Refrigeration system | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | |||
| Condenser | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | |||
| Condenser | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | |||
| Condenser | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | Water-cooled heat exchangerfinned tube heat exchangerStainless steel brazed plate heat exchanger | |||
| Throttle device | Thermal expansion valve, capillary tubing | Thermal expansion valve, capillary tubing | |||
| Refrigeration system | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | |||
| refrigerant | Using environmentally friendly refrigerant R404A + R23 with ozone depletion index of 0 | Using environmentally friendly refrigerant R404A + R23 with ozone depletion index of 0 | |||
| Replenishment method | Three-stage Filter filtrate, pump lift automatic water supply, circulation filtrate recovery | Three-stage Filter filtrate, pump lift automatic water supply, circulation filtrate recovery | |||
| Dehumidification mode | Humidification mode, special dehumidification compressor to start dehumidification, P.I.D control humidification to achieve the required Humidity | Humidification mode, special dehumidification compressor to start dehumidification, P.I.D control humidification to achieve the required Humidity | |||
| Refrigeration system | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | The laboratory adopts a set of binary duplex refrigeration system. The duplex system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle. The heat exchange is realized by evaporative condenserImported cryogenic compressorControl system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator, the compressor return air chill down circuit, and the energy pressure regulating valve according to the test conditionsCompressor overheating, overcurrent, overpressure protection, etc | |||
| Test chamber | Ultimate overtemperature, fan, motor overheating relay | Ultimate overtemperature, fan, motor overheating relay | |||
| Humidification system | Humidification heat pipe dry burning, abnormal water supply, abnormal drainage, abnormal water shortage | Humidification heat pipe dry burning, abnormal water supply, abnormal drainage, abnormal water shortage | |||
| Safety Devices | Leakage protection, overload and short circuit protection | Leakage protection, overload and short circuit protection | |||
| Environmental conditions | Ambient Temperature should be kept within 5 ℃~ + 35 ℃; Relative Humidity: ≤ 85% | Ambient Temperature should be kept within 5 ℃~ + 35 ℃; Relative Humidity: ≤ 85% | |||
| Humidification feed water | Water quality: tap water, equipped with three-stage Filter. Connecting pipe diameter: divided into tap water pipe roots. Water supply pressure: 0.1~ 0.4Mpa | Water quality: tap water, equipped with three-stage Filter. Connecting pipe diameter: divided into tap water pipe roots. Water supply pressure: 0.1~ 0.4Mpa | |||
| gas | No requirement | No requirement | |||
| Humidity resolution | 0.1%RH | 0.1%RH | |||
| Temperature deviation | ±1.5℃ | ±1.5℃ | |||
| Humidity Deviation | ±2%R.H | ±2%R.H | |||
| Temperature Uniformity | ≤2℃ | ≤2℃ | |||
| Humidity Uniformity | ≤3%RH | ≤3%RH | |||
| Temperature Fluctuation | ±0.5℃ | ±0.5℃ | |||
| Humidity stability | ±2%R.H | ±2%R.H | |||
| Cooling rate | + 25 ℃ → -40 ℃ ≤ 60 min (no-load condition) | + 25 ℃ → -40 ℃ ≤ 60 min (no-load condition) | |||
| Condensation method | water cooling | water cooling | |||
Friendly reminder: This page is a comparison of HUDA QD-E705-12m³(-60℃),HUDA QD-E705-20m³(-60℃).NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about HUDA QD-E705-12m³(-60℃),HUDA QD-E705-20m³(-60℃)similarities and differences, please refer to the NBCLab product details.
CopyRight © NBchao.Com 2012-2024, All Rights Reserved.