![]() Bante Bante70 Portable intelligent multiparameter instrument
4150.0 RMB
ChinaDetail
|
![]() Bante Bante90 Portable intelligent multiparameter instrument
4860.0 RMB
ChinaDetail
|
|---|
| Type | Multiparameter | Multiparameter | |||
|---|---|---|---|---|---|
| Style | Portable | Portable | |||
| Measurement parameters | pH/pX DO Conductivity TDS | pH/pX DO Conductivity TDS | |||
| Accessories | |||||
| PH range | -2.000~20.000pH | ||||
|---|---|---|---|---|---|
| pH resolution | 001/0.01/0.1pH, optional | 001/0.01/0.1pH, optional | |||
| Measurement Accuracy of pH | ±0.002pH | ||||
| pH calibrating point | 1 to 5 point | 1 to 5 points | |||
| pH buffering options | USA/NIST/DIN/5 Custom Buffers | USA/NIST/DIN/5 Custom Buffers | |||
| mV range | -2000.0~2000mV | -2000.0~2000mV | |||
| mV resolution | 0.1/1 mV, optional | 0.1/1 mV, optional | |||
| mV Measurement Accuracy | ±0.2mV | ||||
| Temperature compensation range | 0~100 ℃/32~ 212 ° F, Automatic0~100 ℃/32~ 212 ° F, Automatic | 0~100 ° C/32~ 212 ° F, Automatic0~100 ° C/32~ 212 ° F, Automatic | |||
| Stability condition | Fast/standard/high-precisionFast/standard/high-precisionFast/standard/high-precision | Fast/standard/high AccuracyFast/standard/high AccuracyFast/standard/high Accuracy | |||
| Measurement mode | Continuous or automatic endpoint lockingContinuous or automatic endpoint lockingContinuous or automatic endpoint locking | ||||
| Timed interval reading | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | |||
| Calibrated expiration reminder | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | |||
| High/Low Limit Alarm | optionaloptional | optionaloptional | |||
| ORP Measurement range | ±2000.0mV | ||||
| ORP resolution | 0.1/1 mV, optional | 0.1/1 mV, optional | |||
| Measurement Accuracy of ORP | ±0.2mV | ||||
| ORP calibrated point | 1 point | ||||
| ORP Measurement mode | Relative or absolute mV | ||||
| Stability condition | Fast/standard/high-precisionFast/standard/high-precisionFast/standard/high-precision | Fast/standard/high AccuracyFast/standard/high AccuracyFast/standard/high Accuracy | |||
| Measurement mode | Continuous or automatic endpoint lockingContinuous or automatic endpoint lockingContinuous or automatic endpoint locking | ||||
| Timed interval reading | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | |||
| Calibrated expiration reminder | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | |||
| Ion concentration Measurement range | 0.001~ 30000 (depending on the range of the ion selective electrode) | ||||
| Ion concentration Display resolution | 0.001, 0.01, 0.1, 1, automatic | ||||
| Ion concentration Measurement Accuracy | +/- 0.5% F.S. (diion ), +/- 1% F.S. (diion) | ||||
| Ion concentration calibrated point | 2 to 5 point | ||||
| Ion concentration calibrating liquid | 0.001/0.01/0.1/1/10/100/1000/10000 | 0.001/0.01/0.1/1/10/100/1000/10000 | |||
| Ion concentration Measurement unit | ppm,mg/L,mol/L,mmol/L | ||||
| Ion concentration Measuring method | Direct reading, known addition, known reduction, sample addition, sample reduction | ||||
| Ion concentration electrode management | 1 to 3 | 1 to 3 | |||
| Measurement range -mV | ±2000.0mV | ||||
| Ion -mV Display resolution | 0.1/1 mV, optional | ||||
| Ion -mV Measurement Accuracy | ±0.2mV | ||||
| Temperature compensation range | 0~100 ℃/32~ 212 ° F, Automatic0~100 ℃/32~ 212 ° F, Automatic | 0~100 ° C/32~ 212 ° F, Automatic0~100 ° C/32~ 212 ° F, Automatic | |||
| Stability condition | Fast/standard/high-precisionFast/standard/high-precisionFast/standard/high-precision | Fast/standard/high AccuracyFast/standard/high AccuracyFast/standard/high Accuracy | |||
| Measurement mode | Continuous or automatic endpoint lockingContinuous or automatic endpoint lockingContinuous or automatic endpoint locking | ||||
| Timed interval reading | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | 10/30/60/300 seconds or off10/30/60/300 seconds or off10/30/60/300 seconds or off | |||
| Calibrated expiration reminder | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | 1 to 99 days or closed1 to 99 days or closed1 to 99 days or closed | |||
| High/Low Limit Alarm | optionaloptional | optionaloptional | |||
| Hardness Measurement range (concentration) | 0.05~200mmol/L | ||||
| Water Hardness Measurement range (German degrees) | 0~1122°dH | ||||
| Water Hardness Measurement range (UK degrees) | 0~1404°e | ||||
| Hardness Measurement range (French degree) | 0~2000°fH | ||||
| Water Hardness Measurement range (GPG) | 0~1170gpg | ||||
| Hardness Measurement range (CaCO) | 0~20000mg/L | ||||
| Hardness Measurement range (CaO) | 0~11220mg/L | ||||