![]() Model selection comparator
If you have any questions, please click below
|
![]() Apkjgroup AP-HX-1000B Programmable humidity chamber
48900.0 RMB
ChinaDetail
|
![]() Factory NBC-1000L-20 (paint plate) Programmable Constant Temperature & Humidity Test Chamber
30770.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -20℃ | -20℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | >800L | >800L | |||
| TEMP fluctuation | ±0.5℃ | ±0.1℃ | |||
| Humidity deviation | ±2% | ||||
| Studio Volume | 1000L | ||||
|---|---|---|---|---|---|
| Temperature range | -20 ℃~ + 150 ℃ (air-cooled) | -20~150℃ | |||
| Temperature Resolution | 0.01℃ | ||||
| Temperature Fluctuation | ±0.5℃ | ±0.5-1℃ | |||
| Temperature Uniformity | ±2.0℃ | ±1.5-2℃ | |||
| Humidity Control Range | 20~98%R.H | ||||
| Humidity Deviation | ±2%R.H | ±1~2% | |||
| Input Power | |||||
| Environmental temperature | 5~30℃ | ||||
| Working time | |||||
| Power supply Voltage | |||||
| Interior size | 1000*1000*1000mm | 1000*1000*1000mm | |||
| Dimension | 1280*2250*1900mm | ||||
| Weight | About 700kg | ||||
| Cooling rate | RT~ 0 ℃/about 25min (no load) about 1 ℃/min | 1 ℃/min (no-load nonlinear) | |||
| Heating rate | RT~ + 150 ℃/about 40min (no load) about 3 ℃/min | 3 ℃/min nonlinear no-load | |||
| Humidity Accuracy | 0.1%R.H | ||||
| Humidity Uniformity | ≤±3%R.H | ±1-3.0%R.H | |||
| Chamber material | SUS304 stainless steelSUS304 stainless steel | ||||
| Enclosure Material | Cold rolled steel plateLibrary board electrostatic high temperature baking paint | Painted panel | |||
| Outer box light source | High luminance lamp | ||||
| Viewing Window | Observe the use of the sample | ||||
| Window sweat-proof design | Electric heater device to prevent water condensation (40W) | ||||
| test hole | Can be used for external test power cord and signal (diameter 50mm) | ||||
| Machine pulley | Move and adjust the placement position of the mining pulley and fix the position with strong bolts (200Kg/wheel) | ||||
| Insulation material | Rigid polyurethane foam | ||||
| In-box tray rack | Movable adjustable grid plate frame and two stainless steel strip grid plates (5.0cm per grid of the grid frame) | ||||
| Box door | Adopt double-channel heat insulation and air tightness to effectively isolate external temperature leakage | ||||
| Operating Mode | The 0 ℃ to -40 ℃ model adopts one-stage compression, and the -40 ℃ to -70 ℃ model adopts binary cascade refrigeration. | ||||
| Refrigeration system | Original imported French Taikang fully enclosed low noise rotor compressor or Japan Hitachi effective fully enclosed compressor | ||||
| refrigerant | R404a/R23 (ozone depletion index is 0, R23 is used for cascade refrigeration systems) | ||||
| condenser | Air-cooled: finned tube heat exchanger. water-cooled: shell and tube heat exchangerStainless steel brazed plate heat exchanger (used in cascade refrigeration systems) | ||||
| evaporator | Finned tube heat exchanger (also serves as a dehumidifier) | ||||
| condenser | Air-cooled: finned tube heat exchanger. water-cooled: shell and tube heat exchangerStainless steel brazed plate heat exchanger (used in cascade refrigeration systems) | ||||
| Throttle device | Expansion valve + capillary tubing | ||||
| Maximum current consumption | Current: 14A; Power: 3.0KW [Voltage range: no more than +/- 10%] | ||||
| Protection compressor | Compressor high Voltage protection: Danfoss high Voltage protection switch; compressor overcurrent, overheating protection: Schneider thermal relay | ||||
| Protective heater | Chint fuses: 2 groups | ||||
| Protection instrument | Instrument protocol Temperature upper limit Overtemperature protection | ||||
| Chamber material | SUS304 stainless steelSUS304 stainless steel | ||||
| Enclosure Material | Cold rolled steel plateLibrary board electrostatic high temperature baking paint | Painted panel | |||
| Test Shelf | SUS304 box rack with machine pulley, the specific quantity is agreed on site | ||||
| Over temperature protector | Test area over-temperature protection, real-time display test area temperature, temperature over the upper limit sound and light alarm and cut off the instrument Power Supply. | ||||
| Environmental humidity | ≤85% | ||||
| Ambient Pressure | 86kPa~ 106kPa normal atmospheric pressure | ||||