Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermal Shock Test Chamber> Apkjgroup> Compare
      Model selection comparator
      If you have any questions, please click below
      Apkjgroup 2AP-CJ-100A Thermal Shock Test Chamber
      In coming
      ChinaChina
      Detail
      Factory NBC-80B Thermal Shock Test Chamber
      95000.0 RMB
      ChinaChina
      Detail
      Model comparison
      standard Cabinet Cabinet
      Cooling method Air-Cooled Air-Cooled
      Number of cabins Two-Chamber Two-Chamber
      With humidity function without without
      Volume ≤100L ≤100L
      Parameter comparison
      Temperature range -40 ℃~ + 150 ℃ (air-cooled)
      Temperature Fluctuation ±0.5℃ ±2℃
      Temperature deviation ±2.0℃
      Heating rate +50℃→+195℃ ≤40min
      Cooling rate + 20 ℃ → -55 ℃ ≤ Technologies 90min; Note: The cooling time is the performance of the low greenhouse when running alone From room temperature~ -55 ℃ ≤ 60min
      Heating device
      Temperature control method
      Power About 18KW
      Weight Approx. 750kg
      Inner Volume 100L
      Liner size 500*500*400mm
      Dimensions 1500*1950*1850mm
      Low Temperature Impact Range -10 ℃~ -40 ℃ (optional)RT~-55℃
      High Temperature Impact Range 60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃
      Test environmental conditions Environmental temperature around the machine is maintained between + 25~ + 30 ℃, Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure.
      High Temperature Impact Range 60 ℃~ 150 ℃ (arbitrarily adjustable)RT~+195℃
      Heating rate +50℃→+195℃ ≤40min
      Low Temperature Impact Range -10 ℃~ -40 ℃ (optional)RT~-55℃
      Cooling rate + 20 ℃ → -55 ℃ ≤ Technologies 90min; Note: The cooling time is the performance of the low greenhouse when running alone From room temperature~ -55 ℃ ≤ 60min
      Test method Place the product in the hanging basket test area, two boxes of mobile heat & cold shock, safe air pressure drive test object up and down Impact.
      temperature recovery time ≤ 5min; the conversion temperature only needs ≤ 10s (the movement time of the hanging basket: within 3 seconds)
      Impact exposure time ≥30min
      Enclosure Material The outer material can be selected from SUS304 good stainless steel or fine powder paint treatment
      Liner material Stainless steel plate (SUS #304)
      Box insulation material Rigid polyurethane foam
      Air conditioning channel Fan, heating device, evaporator, damper, temperature sensor
      Specimen shelf 1 set, a total of two layers (with four hooks) bearing 25KG (please indicate when placing an order for larger bearing)
      Lead Hole (Optional) 1, located on the left side of the box, with a round hole with a size of 0019 50mm
      Test chamber door Single open, left hinge, right handle
      Circulating Fan High temperature/ambient temperature exposure: 3φ, 400W, centrifugal; low temperature exposure: 3φ, 400W, centrifugal
      Control Panel Controller display, fault indicator, timer, USB or R232 interface, over-temperature protection setter, main power switch
      Mechanical room Refrigeration unit, connected drainage device, exhaust fan
      Distribution control cabinet Total power leakage circuit breaker, Controller, distribution board, heat dissipation fan, high and low temperature Circulating Fan motor
      Heating system Nickel chromium alloy heating wire heating device
      Control mode of heating No touchpoint equal period pulse width modulation, SSR (solid state relay)
      Power cord holes and drainage holes Located on the back of the box
      Refrigeration system France Taikang or Japan Hitachi fully enclosed low noise rotary compressor
      Evaporator finned tube heat exchanger
      Condenser shell and tube heat exchanger
      Throttle device Thermal expansion valve, capillary tubing
      Evaporative condenser Stainless steel brazed plate heat exchanger
      Control mode of refrigerator Control system PLC (programmable logic Controller) automatically adjusts the operating conditions of the refrigerator according to the test conditions, compressor return air chill down circuit, energy regulation circuit, condensing pressure control valve
      refrigerant R404a/R23
      Controller Programmable Controller, touch screen input, different high and low temperature Impact temperature points can be set arbitrarily according to customer requirements to meet different needs for testing
      monitor LCD liquid crystal display
      operation mode procedural approach Program running, constant running
      setting method All Chinese LCD display (Chinese and English can be switched) LCD touch panel (resistant to 100.000 line drawing test)
      program Capacity Up to 120 groups, each program is divided into three zones, three zones and three segments. Each command can be up to 999 times; the program segment time is set to 0~999Hour59Min.
      Display resolution Temperature: 0.1 ℃; Time: 0.1 min
      electrical input Thermocouple
      storage device USB and R232 communication interface
      Control mode Anti-integral saturation PID, fuzzy algorithm; BTC equilibrating temperature control mode
      Curve recording Real-time display of graphics during program execution Linear dispersion
      subsidiary function It has power-off program memory, automatically starts and continues to execute program functions after power-back, with date, time adjustment, appointment start, shutdown function and screen lock (LOCK) function.
      Environmental conditions Temperature: 5 ℃~ 35 ℃; Relative Humidity: ≤ 85%; air pressure: 86kPa~ 106kPa normal atmospheric pressure.
      air source pressure (5~7)kg/cm2
      Air source connecting pipe diameter Φ8mm
      Flow rate of air source 0.1m3/min
      Maximum Power About 12.0KW [Voltage range: no more than +/- 10%]
      Storage environment When the equipment is not working, the temperature of the environment should be kept within 0 ℃~ + 45 ℃; when the Environmental temperature is lower than 0 ℃, the water remaining in the equipment should be discharged clean to avoid the water in the pipeline freezing and damaging the pipeline.
      Maximum current 18A

      Friendly reminder: This page is a comparison of Apkjgroup 2AP-CJ-100A,Factory NBC-80B.NBCLab only provides you with the similarities and differences of the product in the model and specifications.

      For more information about Apkjgroup 2AP-CJ-100A,Factory NBC-80Bsimilarities and differences, please refer to the NBCLab product details.

      Focus on online sales of Lab Testing Instruments