![]() Model selection comparator
If you have any questions, please click below
|
![]() Factory NBC-100L-60 Programmable Constant Temperature & Humidity Test Chamber
20100.0 RMB
ChinaDetail
|
![]() Factory NBC-100L-60 (paint plate) Programmable Constant Temperature & Humidity Test Chamber
20100.0 RMB
ChinaDetail
|
|---|
| Min-TEMP | -60℃ | -60℃ | |||
|---|---|---|---|---|---|
| Max-TEMP | >100℃ | >100℃ | |||
| Min-RH | ≤20%RH | ≤20%RH | |||
| Max-humidity | 98% RH | 98% RH | |||
| Volume | ≤100L | ≤100L | |||
| TEMP fluctuation | ±0.5℃ ±1℃ | ±0.5℃ ±1℃ | |||
| Temperature Uniformity | ≤±2.0℃ | ≤±2.0℃ | |||
| Humidity deviation | ±3% ±5% | ±3% ±5% | |||
| Humidity Uniformity | ≤±5%RH | ≤±5%RH | |||
| Test Type | Constant Temperature & Humidity Alternating Damp Heat | Constant Temperature & Humidity Alternating Damp Heat High Temp & High Humidity (Double 85) | |||
| Cooling Method | Air-cooled | ||||
| Studio volume | 100L | 100L | |||
|---|---|---|---|---|---|
| Temperature range | -60~150℃ | -60~150℃ | |||
| Temperature resolution | |||||
| Temperature Fluctuation | ±0.5-1℃ | ±0.5-1℃ | |||
| Temperature Uniformity | ±1.5-2℃ | ±1.5-2℃ | |||
| Humidity Control Range | 20~98%R.H | 20~98%R.H | |||
| Humidity deviation | Humidity < 75% is ± 5%, Humidity > 75% is ± 3% | Humidity < 75% is ± 5%, Humidity > 75% is ± 3% | |||
| Input Power | |||||
| Working environment | |||||
| Continuous Operating Time | |||||
| Power supply voltage | 220V/50HZ | 220V/50HZ | |||
| Inner chamber dimensions | 500*400*550mm | 500*400*550mm | |||
| Dimension | 1020*950*1420mm | 1020*950*1420mm | |||
| Shelf (std.) | |||||
| Humidity uniformity | Humidity < 75% is ± 5%, Humidity > 75% is ± 3% | Humidity < 75% is ± 5%, Humidity > 75% is ± 3% | |||
| heating rate | 3 ℃/min nonlinear no-load | 3 ℃/min nonlinear no-load | |||
| cooling rate | 1 ℃/min (no-load nonlinear) | 1 ℃/min (no-load nonlinear) | |||
| Inner chamber dimensions | 500*400*550mm | 500*400*550mm | |||
| Dimension | 1020*950*1420mm | 1020*950*1420mm | |||
| weight | ≈170KG | ≈170KG | |||
| Power supply voltage | 220V/50HZ | 220V/50HZ | |||
| voltage fluctuation allowable value | ±10% | ±10% | |||
| Maximum Power | 6kw | 6kw | |||
| Inner chamber material | Mirror stainless steel plate (SUS #304) | Mirror stainless steel plate (SUS #304) | |||
| Enclosure Material | Mirror stainless steel plate (SUS #304) | Painted panel | |||
| Working Ambient Temperature | 0~30℃ | 0~30℃ | |||
| Performance assurance environment | 5~25℃ | 5~25℃ | |||
| Operating Environment Requirements | Miscellaneous items cannot be placed within 60CM | Miscellaneous items cannot be placed within 60CM | |||
Friendly reminder: This page is a comparison of Factory NBC-100L-60,Factory NBC-100L-60 (paint plate).NBCLab only provides you with the similarities and differences of the product in the model and specifications.
For more information about Factory NBC-100L-60,Factory NBC-100L-60 (paint plate)similarities and differences, please refer to the NBCLab product details.