| Measurable Materials | The material itself | The material itself | |||
|---|---|---|---|---|---|
| Measuring Range | Miscellaneous | 0~100mm | |||
| Error | 0.1% | 0.1% | |||
| Calibration Certificate | No certificate | No certificate | |||
| Probe Type | Split probe | Split probe | |||
| Application environment | |||||
| Coating Penetration | |||||
| Accessories | |||||
| Measurement range | 0.8~ 500Mm (standard mode); 3.0~20mm (coating mode), depending on the probe used, the material tested, and the surface condition | ||||
|---|---|---|---|---|---|
| Probe Frequency | |||||
| Probe style | Split probe | S1507, single crystal probe | |||
| Probe diameter | |||||
| Probe line | |||||
| Sensors Contact Temperature | |||||
| Lower limit of pipe measurement | |||||
| Measurement error | When resolution is 0.01mm, thickness H < 10mm, error of indication +/- 0.05mmWhen resolution is 0.01mm, thickness H ≥ 10mm, error of indication +/- (0.1% H + 0.05) mm When resolution is 0.1mm, error of indication +/- (1% H + 0.1) mm | ± 0.04mm (Film thickness < 9.99mm), ± (0.1% Film thickness value + 0.04) mm Film thickness value = 10~99.9mm | |||
| Display resolution | 0.01Mm, 0.1mm optional | 0.001mm/0.0001inch | |||
| unit system | mm | mm/inch | |||
| Calibration method | |||||
| Measurement mode | Pulse~ echo mode, echo~ echo mode, reverse measurement Speed of sound | Average measurement, 2 to 9 times optional | |||
| Repeatability | |||||
| Measurement speed | 2 sec/sec or 10 times/sec fast measurement mode | ||||
| Storage Capacity | 100 groups of files, each group of files can store 100 data, a total of 10,000 data | ||||
| data statistics | |||||
| Speed of sound | 1000~9999m/s | ||||
| Speed of sound storage | |||||
| Standards | |||||
| Display | LCD display (with backlight) | 320 * 240 color screen display | |||
| Operating language | Chinese | Chinese | |||
| Interface | |||||
| Application Software | none | ||||
| Protection level | |||||
| Environmental temperature | -10~60℃ | ||||
| Working Relative Humidity | <90%RH | ||||
| Storage temperature | |||||
| Power Supply | |||||
| power consumption | |||||
| Operating Time | |||||
| Host size | 146*81*30mm | 133*75*29mm | |||
| Weight | 300g | 260G (including battery) | |||
| Application | |||||
| Data storage method | Storage method | ||||