| Type | Portable | Portable | |||
|---|---|---|---|---|---|
| Number of Gases | Single gas | Single gas | |||
| Sensors | |||||
| Gases | O2 | O2 | |||
| Sampling Mode | Diffusion | Diffusion | |||
| Detect gas | Oxygen O2 | ||||
|---|---|---|---|---|---|
| Sensors principle | principle of zirconia | ||||
| Sampling method | Diffusion, circulation | ||||
| O2-range | 0~5000PPm | ||||
| O2- resolution | 0.01PPm | ||||
| O2- detection Accuracy | ±3%F.S. | ||||
| Operation mode | Infrared remote control for remote and close operation, easy to set up | ||||
| Repeatability | ≤±1% | ||||
| Zero drift | ≤ +/- 1% (F. S/year) | ||||
| Response time | T90≤20s | T90<60s | |||
| recovery time | ≤20s | ||||
| Explosion-proof sign | Exd Ⅱ CT6 | ExibIICT4Gb | |||
| Protection level | IP66 | ||||
| Output signal | Users can according to the actual site environment requirements, up to 2000 meters (single core 1mm2 Shielding cable) three-wire system 4-20mA current signal output, can be connected to the alarm Controller, PLC, DCS and other Control system (standard configuration) | ||||
| main material | Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber) | ||||
| Installation method | Wall-mounted, pipeline type | ||||
| Operating temperature | -30~60℃ | ||||
| Environmental humidity | 0~95% RH non-condensing10%~95%RH | ||||
| Environmental humidity | 0~95% RH non-condensing10%~95%RH | ||||
| Power Supply | 24VDC (Normal Operating Voltage range 12~ 30VDC) | ||||
| power consumption | 1.5W | ||||
| Operating Pressure | ≤200Kpa | ||||
| Dimension | 180*140*92mm | ||||
| Weight | About 1.6Kg | ≤ 172G (without portable accessories) | |||
| execution standard | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 | ||||