| Type | Portable | Portable | |||
|---|---|---|---|---|---|
| Measurement method | Contact | Contact | |||
| Measurement Aperture | F8mm | F8mm Miscellaneous | |||
| Light source | LED light source | LED light source | |||
| Integrating sphere | > F40mm | ≤ F40mm | |||
| Color Repeatability | ≤0.05 | ≤0.06 | |||
| Aperture Shape | plane | plane curved surface | |||
| software | computer software | computer software | |||
| Special features | |||||
| Lighting method | D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | D/8 (diffuse illumination, 8 ° direction reception) SCI/SCE measurement conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | |||
|---|---|---|---|---|---|
| Sensors | 256-Pixel dual array CMOS image sensor | ||||
| Wavelength range | 400~700nm | 400~700nm | |||
| lighting source | Combination LED light source | Light spectrum LED light source | |||
| Measurement time | Approx. 1.0s (Simultaneous test SCI/SCE approx. 2.6s) | About 1.5s (about 3.2s for simultaneous test SCI/SCE) | |||
| Measurement caliber | F8mmF10mm | Single diameter: Φ8mm/Φ10mm | |||
| Spectral reflectance repeability | MAV/SCI, standard deviation within 0.1% (400~700nm: within 0.2%) | ||||
| Operating language | Simplified Chinese, English | Simplified Chinese, English, Traditional Chinese | |||
| Data Interface | USB/RS-232, Bluetooth ® 4.0 Dual Mode (2.1 Compatible) | USB | |||
| Viewing Angle | CIE 2 ° / 10 ° | CIE 2 ° / 10 ° | |||
| Observation light source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,TL83,TL84,U30,CWF,U35 | ||||
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE(Hunter) | ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99 | |||
| Data storage | 1000 master standards and 20,000 samples (one piece of data can include SCI/SCE at the same time) | 1000 master standards and 20,000 samples (one piece of data can include SCI/SCE at the same time) | |||
| Power | Lithium battery, 5000 times in 8 hours | ||||
| Display | TFT true color 3.5inch, capacitive touch screen | TFT true color 3.5inch, capacitive touch screen | |||
| Operating conditions | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m | |||
| Storage environment | -20~50 ℃, 0~85% RH (no condensation) | -20~50 ℃, 0~85% RH (no condensation) | |||
| Dimensions | 184*77*105mm | 81*71*214mm | |||
| Weight | Approx. 600g | About 460g | |||
| Integrating sphere size | F48mm | F40mm | |||
| Spectroscopic method | Concave grating spectroscopy | Plane grating spectroscopy | |||
| wavelength spacing | 10nm | 10nm | |||
| Light spectrum half bandwidth | 10nm | 10nm | |||
| Reflectance Measurement Range | 0~200% | L: 0~120 reflectance: 0~200% | |||
| Light-containing method | Simultaneous testing of SCI/SCE | Simultaneous testing of SCI/SCE | |||
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB | CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy,Munsell(C/2) | |||
| Chromaticity indicator | WI, YI, TI, homochromatic index MI, lightfastmess, color fastness, force, coverage, 8 degree glossiness | WI, YI, homochromatic index MI, lightfastmess, color fastness, force, coverage, color chip retrieval | |||
| display mode | Light spectrum/data, sample chromatic values, color difference values/graphs, pass/fail results, Color bias | Light spectrum graphs/data, sample chromatic values, color difference values/graphs, pass/fail results, Color simulation, Color bias | |||
| Inter-station difference | ΔE * from < 0.2 (MAV / SCI) | ΔE * from < 0.3 (MAV / SCI) | |||
| Measurement mode | Single measurement, average measurement (2~ 99 times) | Single measurement, average measurement (2~ 99 times) | |||
| Positioning method | Camera positioning | Camera positioning, stabilizer positioning | |||
| Lighting source life | 5 years more than 3 million measurements | 5 years more than 3 million measurements | |||
| Measurement caliber | F8mmF10mm | Single diameter: Φ8mm/Φ10mm | |||
| Chromatic value repeability | MAV/SCI,ΔE*ab 0.04以内 | MAV/SCI,ΔE*ab 0.06以内 | |||