      The JJG 595-2002 standard specifies the methods of verification and technical requirements for color difference meters. It provides a systematic verification procedure to ensure the accuracy and conformity of color difference meters when measuring Color. The standard covers the steps, conditions and equipment and techniques required for verification to guarantee that the measurement results of color difference meters meet the specified standards and requirements. This is essential to ensure the accuracy and conformity of Color measurement, especially in areas where Color matching is required for Coatings, Printing and Miscellaneous.

      This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
      Status Active
      CCS ICS
      Release Date Implementation Date
      12 in total
      filter
      Featured Hot Price Time
      CHINA LS177 Large aperture desktop spectroscopic Colorimeter Powder, Masterbatch Color detection
      $1412.00 SE
      CHINA LS177 Large aperture desktop spectroscopic Colorimeter Powder, Masterbatch Color detection
      Delta E * ab ≤ 0.4 (BCRA II series 12 color brick measurement average)50mm
      +Compare
      CHNSPEC DS-220 Colorimeter 11mm + 6mm + 3mm caliber
      $541.00 SE
      CHNSPEC DS-220 Colorimeter 11mm + 6mm + 3mm caliber
      Three kinds: Should 11mm, Should 6mm, Should 3mm
      +Compare
      CHINA LS176 Colorimeter Colorimeter
      $632.00 SE
      CHINA LS176 Colorimeter Colorimeter
      8mmDelta E * ab < = 0.4 (BCRA II series 12 color brick measurement average)
      +Compare
      3NH PS2010 Colorimeter φ 8mm caliber
      $491.00 SE
      3NH PS2010 Colorimeter φ 8mm caliber
      Single diameter: Φ8mm/Φ10mm (platform measurement diameter)Chromatic value: MAV/SCI, standard deviation ΔE * ab within 0.04 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.1% (400~700nm: within 0.2%)
      +Compare
      Kutai MS3003 Multi-angle Colorimeter Industrial MCU 3 Measurement angles
      Kutai MS3003 Multi-angle Colorimeter Industrial MCU 3 Measurement angles
      F12mm0.2ΔE * 00 (BCRA series Ⅱ 12 color plate measurement average)
      +Compare
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      $1450.00 SE
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      Four caliber: MAV: Should 8mm/Should 10mm (platform + tip nozzle measurement diameter); SAV: Should 4mm/Should 5mm (platform + tip nozzle measurement diameter)Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.2(MAV/SCI)
      +Compare
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      $1293.00 SE
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      Three caliber: MAV: Should 8mm/Should 10mm (platform measurement diameter); SAV: Should 4mm/Should 5mm (platform measurement diameter); SSAV: 1x3mm (pointed nozzle measurement diameter);Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.3(MAV/SCI)
      +Compare
      Focus on online sales of Lab Testing Instruments