Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )

      The standard "GB/T 36142-2018 Architectural Glass Color and color difference measurement method" specifies the measurement method of architectural Glass transmission and reflection Color and color difference, including terminology, measurement principle, sample requirements, Light spectrum transmittance and reflection ratio measurement, Color calculation, color difference calculation and test report preparation. The standard applies to single-layer or multi-layer architectural Glass with mirror reflection characteristics to ensure the accuracy and conformity of the measurement process. The standard does not apply to Glass products with diffuse characteristics. Through standardized measurement methods, Color characteristics and color differences of Architectural Glass can be accurately evaluated to meet design and quality control requirements.

      This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
      Status Active
      CCS Q30 ICS 81.040
      Release Date 2018-05-14 00:00:00 Implementation Date 2019-04-01 00:00:00
      5 in total
      filter
      Featured Hot Price Time
      CHNSPEC DS-220 Colorimeter 11mm + 6mm + 3mm caliber
      $537.00 SE
      CHNSPEC DS-220 Colorimeter 11mm + 6mm + 3mm caliber
      Three kinds: Should 11mm, Should 6mm, Should 3mm
      +Compare
      3NH PS2010 Colorimeter φ 8mm caliber
      $487.00 SE
      3NH PS2010 Colorimeter φ 8mm caliber
      Single diameter: Φ8mm/Φ10mm (platform measurement diameter)Chromatic value: MAV/SCI, standard deviation ΔE * ab within 0.04 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.1% (400~700nm: within 0.2%)
      +Compare
      Kutai MS3003 Multi-angle Colorimeter Industrial MCU 3 Measurement angles
      Kutai MS3003 Multi-angle Colorimeter Industrial MCU 3 Measurement angles
      F12mm0.2ΔE * 00 (BCRA series Ⅱ 12 color plate measurement average)
      +Compare
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      $1439.00 SE
      3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
      Four caliber: MAV: Should 8mm/Should 10mm (platform + tip nozzle measurement diameter); SAV: Should 4mm/Should 5mm (platform + tip nozzle measurement diameter)Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.2(MAV/SCI)
      +Compare
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      $1283.00 SE
      3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
      Three caliber: MAV: Should 8mm/Should 10mm (platform measurement diameter); SAV: Should 4mm/Should 5mm (platform measurement diameter); SSAV: 1x3mm (pointed nozzle measurement diameter);Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)ΔE*ab<0.3(MAV/SCI)
      +Compare
      Focus on online sales of Lab Testing Instruments