This standard specifies the method for the determination of tin content in sponge titanium, titanium and titanium alloys, and the applicable range is 0.05% to 12.00% of tin content. Method 1 is the potassium iodate Titrimetric method, and the determination range is 1.00% to 12.00%; Method 2 is the Inductance coupled plasma atomic emission spectroscopy (AES) method, which is an arbitration analysis method, and the applicable range is 0.05% to 12.00%. The standard details the sample dissolving, titration process and the treatment of interfering factors to ensure the accuracy of tin content determination.
This summary is not the original standard text and is for reference only. For accurate information, please obtain it through official channels.
| Status | Active | ||
|---|---|---|---|
| CCS | H14 | ICS | 77.120.50 |
| Release Date | 2017-09-29 00:00:00 | Implementation Date | 2018-04-01 00:00:00 |