MODERNER CNDB-2 Zahn Viscosity Cup (zahn cup) 2.7mm Zahn cup
2.7mm20~80sASTM D4212-93
Viscosity range 20~230cSt, outflow time 20~80s, flow hole diameter 2.7mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

Login
MODERNER CNDB-4 Zahn Viscosity Cup (zahn cup) 4.3mm portable Zahn cup
4.3mm20~80sASTM D4212-93
Viscosity range 220~1100cSt, outflow time 20~80s, flow hole diameter 4.3mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

Login
MODERNER CNDB-1 Zahn Viscosity Cup (zahn cup) 1mm portable Zahn cup
2.0mm35~80sASTM D4212-93
Viscosity range 5~ 60cSt, outflow time 35~ 80s, flow hole diameter 2mm, capacity 45ml, applicable to standard ASTM D4212-93.

Login
MODERNER FORD-4 No. 4 Ford Viscosity Cup viscosity range 49~ 220cst
20~100sASTM D1200
Desktop with stent; anodic oxidation aluminum cup + brass leakage; measurement range 70-370 centimeters; outflow time 20-100 seconds; ASTM/D 1200 standard.

Login
MODERNER CNDB-3 Zahn Viscosity Cup (zahn cup) 3.8mm Zahn cup
3.8mm20~80sASTM D4212-93
Viscosity range 150~850cSt, outflow time 20~80s, flow hole diameter 3.8mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

Login
MODERNER CNDB-5 Zahn Viscosity Cup (zahn cup) 5.3mm newtonian fluid Viscosity Cup
5.3mm20~80sASTM D4212-93
Viscosity range 460~1840cSt, outflow time 20~80s, flow hole diameter 5.3mm, capacity 45ml, cup body material stainless steel, filter material stainless steel, handle material stainless steel, applicable standard ASTM D4212-93.

Login
MODERNER T-4 coated 4 Viscosity Cup aluminum alloy material
4mm30~100sGB/T 1723
100Ml volume, 4mm aperture, aluminum alloy cup nozzle, stainless-steelbeaker body, desktop with bracket.

Login
MODERNER FORD-5 No. 5 Ford Viscosity Cup for the determination of Newtonian fluids such as varnishes, paints, and paints
20~100sASTM D1200
FORD-5 Ford Viscosity Cup, viscosity range 200~1200cSt, outflow time 20~100s, applicable to standard ASTM D1200

Login
MODERNER FORD-2 No. 2 Ford Viscosity Cup anodic oxidation aluminum cup body viscosity range 20~120cst
40~100s
Viscosity range 20~120cSt, outflow time 40~100s, cup body material anodic oxidation of aluminum, filter material brass.

If you don't know how to choose "Viscosity Cup", please consult customer service.