$836.00
SE
HANNA HI76483 Built-in temperature sensor dissolved Oxygen electrode
Built-in thermistor temperature sensor to compensate for temperature changes from 0 to 50 ℃, with platinum cathode and Ag/AgCl anode assembly, bottle cap made of durable plastic material with polytetrafluoroethylene (PTFE) oxygen permeable membrane.

$262.00
SE
HANNA HI76483A/P special PTFE dissolved oxygen membrane
The cap is made of a durable plastic material with a polytetrafluoroethylene (PTFE) oxygen permeable membrane that separates the probe cathode and anode from the sample being tested.

$147.00
SE
HANNA HI76409 Built-in temperature sensor Current dissolved Oxygen electrode
Contains a sterling silver cathode and a zinc anode with an integrated temperature sensor with a membrane covering the Current Sensors and built-in thermistors for temperature measurement and compensation.

$845.00
SE
HANNA HI76408W Built-in temperature sensor dissolved Oxygen electrode (suitable for BOD determination)
Featuring a longer probe shaft and integrated stopper, designed to fit directly into B.O.D. bottles, the probe is made of durable ABS plastic and contains an integrated temperature sensor for temperature compensation measurement.

$654.00
SE
HANNA HI764103 Built-in temperature sensor and electronic chip to dissolve Oxygen electrode
Automatic compensation based on temperature changes, built-in microchip stores Sensor type, serial number and calibrated information, silver cathode with zinc anode, integrated temperature sensor and easy-to-replace HDPE film cover.

$584.00
SE
HANNA HI764073 Special dissolved Oxygen electrode (built-in temperature sensor)
Operating temperature range 0 to 50 ℃, fast calibrating, Measured value for temperature compensation, sensitive PTFE membrane can be replaced in seconds, ideal for field use.

$520.00
SE
HANNA HI3148B ORP electrode Glass body
±2000mV
The HI3148B features a Glass body, an open connection using CPS technology, and can be refilled with 3.5 M potassium chloride.

$742.00
SE
HANNA HI764080 Built-in temperature sensor Digital dissolved Oxygen electrode
0 to 300% oxygen saturation
Measurement range 0 to 300% oxygen saturation, Operating temperature range 0 to 50 ℃, integrated temperature sensor and easily replaceable PTFE membrane cover, the ability to transfer information allows hot swapping of the probe without recalibrating.

$817.00
SE
HANNA HI764080 Digital dissolved Oxygen electrode (built-in temperature sensor)
0 to 300% oxygen saturation
Measurement range 0 to 300%, Operating temperature range 0 to 50 ℃, Built-in microchip with platinum cathode with silver/silver chloride anode, integrated temperature sensor and easily replaceable PTFE membrane cover.

$122.00
SE
DDKSIC ORP301 composite ORP electrode for waste water, swimming pool water measurement
Platinum pin, +/- 1999mV
Electrode shell plastic shell, cable length 1 meter, electrode interface BNC, reference solution 3mol KCl gel - non-additive, specification φ 12mm × 120mm, Measurement range Platinum needle, +/- 1999mV

$164.00
SE
DDKSIC DO01-2M Polarographic dissolved Oxygen electrode for environmental protection, water treatment, aquaculture, etc
0~20Mg/L, 0~200% saturation
Electrode shell polyformaldehyde (POM), cable length 2 meters, built-in temperature 10KΩ, electrode interface BNC (Q9)/BNC (Q6), reference solution can be added, specification φ 12mm × 120mm, Measurement range 0~20mg/L, 0~200% saturation

$101.00
SE
DDKSIC TEMP-01 Temperature electrode BNC (Q6) conventional aqueous solution
0-110℃
Electrode shell stainless steel, cable length 1 meter, built-in temperature 10KΩ, electrode interface BNC (Q6), reference solution -, specification φ 5mm × 120mm, Measurement range 0-110 ℃

$101.00
SE
DDKSIC TEMP-02H temperature electrode 4 core, conventional aqueous solution
0-110℃
Electrode shell stainless steel, cable length 1 meter, built-in temperature 10KΩ, electrode interface 4 cores, reference solution -, specification φ 5mm × 120mm, Measurement range 0-110 ℃

$164.00
SE
DDKSIC DO01-2M-H Polarographic dissolved Oxygen electrode for environmental protection, water treatment, aquaculture, monitoring oxygen content in water
0~20Mg/L, 0~200% saturation
Electrode shell polyformaldehyde (POM), cable length 2 meters, built-in temperature 10KΩ, electrode interface 8 cores, reference solution can be added, specification φ 12mm × 120mm, Measurement range 0~20mg/L, 0~200% saturation

$612.00
SE
DDKSIC ODO01-10M Optical inspection type dissolved Oxygen electrode monitors oxygen content in water, without consuming oxygen in water, without frequent replacement of diaphragm
0~20Mg/L, 0~200% saturation
Electrode shell polyformaldehyde (POM)/stainless steel sedimentation (protection) sleeve, cable length 10 meters, built-in temperature 10KΩ, electrode interface 8 core, reference solution -, specification φ 22mm × 150mm, Measurement range 0~20mg/L, 0~200% saturation

$586.00
SE
DDKSIC ODO01-3M Optical inspection type dissolved Oxygen electrode monitors oxygen content in water without consuming oxygen in water and without frequent diaphragm replacement
0~20Mg/L, 0~200% saturation
Electrode shell polyformaldehyde (POM)/stainless steel sedimentation (protection) sleeve, cable length 3 meters, built-in temperature 10KΩ, electrode interface 8 core, reference solution -, specification φ 22mm × 150mm, Measurement range 0~20mg/L, 0~200% saturation

$274.00
SE
BANTE DO100 type dissolved Oxygen electrode film laminating dissolved Oxygen electrode
Polarographic, saturated output 400 nA ( +/- 25%), zero output < 1%, operating Environmental temperature 0~80 ℃, 32~ 176 ° F, shell material epoxy resin

$158.00
SE
BANTE 502 ORP electrode for measurement of weak Oxidation-reduction potential
Ring platinum, Operating Environmental temperature 0~80 ℃, 32~ 176 ° F, Reference type Ag/AgCl, Liquid interface type PTFE, Housing material PC

If you don't know how to choose "STIP-scan", please consult customer service.