$489.00
SE
JINGQI WD8107 Fluoride Tester
fluoride0.05~2.00mg/L
Measurement range 0.05~ 2.00mg/L, error of indication ≤ +/- 5%, resolution 0.01mg/L, Repeatability ≤ 3%, large-screen LCD Chinese display and Chinese menu operation.

$489.00
SE
JINGQI WD8204 Aluminum Tester
aluminum0.01~4.00mg/L
Measurement range 0.01~ 4.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%

$3513.00
SE
TONGAO TR 6900CN Benchtop STIP-scan detection of COD/Total nitrogen
Detect the content of COD and Total nitrogen in water, use the persulfate oxidation method to detect the Total nitrogen value, the measurement error is ≤ +/- 5%, and the built-in thermal printer.

$2692.00
SE
TONGAO TR 6900NHP STIP-scan detection of ammonia nitrogen/Total phosphorus/turbidity/suspended solids
Ammonia nitrogen, total phosphorus, turbidity, suspended solids
Detect ammonia nitrogen, Total phosphorus, turbidity, suspended solids (SS) four parameters, Miscellaneous water quality detection parameters can be expanded, built-in thermal printer, can store 30,000 measurement data.

$489.00
SE
JINGQI WD8221 alkalinity Tester
Alkalinity0.00~1000.0mg/L
Measurement range 0.00~1000.0mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%

$3008.00
SE
TONGAO TR 6900NHN Benchtop STIP-scan detection of ammonia nitrogen and Total nitrogen
Ammonia nitrogen, total nitrogen
The content of ammonia nitrogen and Total nitrogen in water was detected, and the digestion Colorimetric integrated tube Colorimetric was used to directly display the results. The HJ535-2009 Knoll reagent Spectrophotometric method, spec-trophotometry and HJ535-2009 Knoll reagent Spectrophotometric method, spec-trophotometry were used.

$2692.00
SE
TONGAO TR 6900B Desktop COD, Ammonia Nitrogen Tester
Detect COD, ammonia nitrogen content, in line with HJ535-2009, HJ/T399-2007 standards, built-in thermal printer, using digestion Colorimetric integrated tube Colorimetric.

$1287.00
SE
HANNA HI2004 Desktop saturated Dissolved Oxygen Meter
Measurement range - dissolved oxygen 0.00 to 45.00 ppm (mg/L); 0.0 to 300.0% saturation, resolution - dissolved oxygen 0.01 ppm (mg/L); 0.1% saturation, the instrument has the function of automatically identifying electrodes, sensor type, calibrated data, factory number and other electrode parameters.

$618.00
SE
HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer
Measurement range 0.00 to 2.00 mg/L (as ClO2), resolution 0.01 mg/L, accuracy @25 ℃ reading +/- 0.10 mg/L +/- 5%, high quality Optical inspection filter, High measurement Stability and less wavelength error ensure Measurement accuracy and accuracy.

$2850.00
SE
TONGAO TR 6900CP Benchtop STIP-scan detection of COD/Total phosphorus/turbidity/suspended solids (SS)
COD, total phosphorus, turbidity, suspended solids
At the same time, the content of COD, Total phosphorus, turbidity and suspended solids (SS) in the water was detected, which met the standards. The built-in thermal printer was used, and the digestion Colorimetric integrated tube Colorimetric was used.

$302.00
SE
QIWEI NS-1T desktop urea Detector measurement range 0-10mg/L
0-10mg/L
Measurement range 0-10mg/L, resolution 0.1mg/L, sexual repeability ≤ 2%, error of indication +/- 5% FS, suitable for indoor and outdoor swimming pool water quality testing and various water plants, in order to control the water urea to meet the specified water quality standards.

$755.00
SE
DDKSIC PC100 Benchtop pH, Conductivity Meter pH/mV (ORP electrode optional)/conductivity/resistivity/TDS/salinity/℃
pH, mV (ORP electrode optional), conductivity, resistivity, TDS, salinity, ℃(-9.9~130.0)°C/(14.1~266.0)°F(-2.000~20.000)pH
PC100 desktop pH, Conductivity Meter, conductivity module: 1 point calibrated, reference temperature: 18 ℃, 20 ℃, 25 ℃ optional, support electrode calibration, standard solution calibration, standard series: CH, Europe and the United States optional, measurement can be switched to TDS/salinity/resistivity.

$2295.00
SE
HANNA HI83314 Desktop acidity pH-COD multiparameter water quality Tester
COD, total nitrogen, total phosphorus and other wastewater treatment digestion parameters- 2.00-16 pH (pH-mV conversion: 1000.0mV)
Acidity pH range 2.00-16 pH, resolution pH0.01pH (0.1mV), accuracy 0.01pH (0.2MV), automatic temperature compensation, built-in standard calibrate points, nearly 75 water quality measurement items, suitable for laboratory, field or field rapid water quality measurement.

$593.00
PromotionSE
HANNA HI97701 Portable residual chlorine photometer
0.00-5.00mg/L
Measurement range 0.00-5 mg/L, resolution 0.01mg/L, accuracy @25 ℃ reading +/- 3% +/- 0.03mg/L, LED high-quality Light source system, high-quality Optical inspection filter to ensure that the sample measurement results are consistent with the user.

$1461.00
SE
TONGAO TR 6900NH Benchtop Ammonia Nitrogen STIP-scan
ammonia nitrogen
Detection of ammonia nitrogen content, range 0.01-50 mg/L, using HJ535-2009 detection method, built-in thermal printer, using digestion Colorimetric integrated tube.

$624.00
SE
DDKSIC PH100T Laboratory pH Meter Touch Screen pH/mV (ORP electrode optional)/℃
pH, mV (ORP electrode optional), ℃-2.000~20.000ph
-2.000~20.000pH, accuracy +/- 0.002pH, Intelligent Operating system, with electrode management, data management, parameter setting, data locking, Automatic calibration and other functions.

$605.00
SE
HANNA HI97701 residual chlorine [free chlorine] Portable Photometer
residual chlorine0.00-5.00mg/L
The HI97701 is a portable residual chlorine photometer with outstanding performance and a convenient portable design. Compliant with IP67 waterproof standards, it adopts an innovative Optical inspection system design to ensure high-precision, repeatability, and more efficient measurement time.

$618.00
SE
HANNA HI97751 Sulfate Portable Photometer
0 to 150 mg/L (e.g. SO42-)
Measurement range 0 to 150 mg/L (e.g. SO42-), resolution 1 mg/L, accuracy @25 ℃: +/- 5 mg/L +/- 3%, commonly used in water quality monitoring, environment protection and industrial production.

$751.00
SE
HANNA HI97105 multiparameter photometer for seawater
LED Light source, bandpass filter wavelength 525 & 610 nm; Bandwidth 8nm; Wavelength Accuracy +/- 1.0 nm, can be used for the measurement of pH acid alkalinity, calcium ions, nitrate, phosphoric acid and other parameters, is a powerful and widely used water quality analysis instrument.

$2850.00
SE
TONGAO TR 6900N Benchtop Total Nitrogen STIP-scan
total nitrogen0~100mg/L
Detect Total nitrogen content, range 0.5-100mg/L, use persulfate oxidation method, built-in thermal printer, use digestion Colorimetric integrated tube, standard detection program Total nitrogen L and Total nitrogen H.

$618.00
SE
HANNA HI97770 Silica/Silicon [HR] Portable Photometer
Measurement range 0 to 200 mg/L (as SiO2), resolution 1 mg/L, accuracy @25 ℃: +/- 1 mg/L +/- 5% of reading, widely used in water treatment, drinking water monitoring, environment protection and industrial process control.

$1676.00
SE
HANNA HI6221 Benchtop acidity meter, a new generation of desktop pH/ORP meter
±2000mV-2.0 to 20.0 pH;-2.00 to 20.00;-2.000 to 20.000pH
Measurement range -pH-2.0 to 20.0 pH; -2.00 to 20.00; -2.000 to 20.000 pH, 7-inch capacitive touchscreen, equipped with an electrode holder with a flexible arm, the holder can be quickly installed.

$618.00
SE
HANNA HI97762 ULR residual chlorine [free chlorine] Portable Photometer
Residual chlorine Measurement range 0.00 to 10.00 mg/L (as Cl2), resolution 0.01 mg/L, accuracy reading of +/- 0.03 mg/L +/- 3%, widely used in water treatment, swimming pool monitoring, drinking water mass detection, etc.

$950.00
SE
DDKSIC CD100T touch screen desktop conductivity Dissolved Oxygen Meter conductivity/resistivity/TDS/salinity/dissolved oxygen concentration/dissolved oxygen saturation/℃
Conductivity, resistivity, TDS, salinity, dissolved oxygen concentration, dissolved oxygen saturation, ℃
CD100T desktop touch screen conductivity, Dissolved Oxygen Meter, intelligent Operating system, with electrode management, data management, parameter setting, data locking, Automatic calibration and other functions.

$618.00
SE
HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.

$2164.00
SE
HANNA HI5521 Professional desktop multiparameter water quality Tester
0.000 to 9.999、10.00 to 99.99、100.0 to 999.9 mg/L(ppm);1.000 to 9.999、10.00 to 99.99、100.0 to 400.0 g/L(ppt);TDS转换系数:1.00-2.0 to 20.0 pH;-2.0 to 20.00;-2.000 to 20.000 pH
Capacitive touch button, 5-point pH automatic recognition calibrate, built-in 8 standard points, 5 custom calibrates; up to four-point EC calibrate and single-point salinity calibrate; 50,000 data/group, with screen measurement and calibrate operation prompts, convenient and fast.

$618.00
SE
HANNA HI97753 chlorides [CI] Portable Photometer
Measurement range 0.0 to 20.0 mg/L (e.g. Cl -), resolution 0.1 mg/L, accuracy @25 ℃: +/- +/- 6% of reading at 25 ℃, widely used in water treatment, environment monitoring, industrial production and other fields.

$618.00
SE
HANNA HI97739 Fluoride HR Portable Photometer
0.00-20.00mg/L
Measurement range 0.00-20 mg/L, resolution 0.01mg/L, accuracy @25 ℃: +/- 3 %; +/- 0.5mg/L of reading, commonly used in drinking water monitoring, industrial production process control and other fields to ensure that the concentration of fluoride ions in water is within the safe range.

$618.00
SE
HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
Measurement range of iron 0.00 to 1.60 mg/L (as Mn), resolution 0.01 mg/L, Mn Measurement range 0 to 300 μg/L (as Mn), resolution 1 μg/L, commonly used in environment monitoring, wastewater treatment, drinking water mass detection and other fields.

$618.00
SE
HANNA HI97769 Surfactant [SDBS] Portable Photometer
Measurement range 0.00 to 3.50 mg/L (as SDBS), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.04 mg/L +/- 3% of reading, widely used in water treatment, environment monitoring, detergent production and detergent residue detection.

If you don't know how to choose "STIP-scan", please consult customer service.