$679.00
SE
KOSON KS-150 In-situ single shear Tester, masonry shear strength Tester 150KN thrust
It adopts manual pump loading cylinder design, rated thrust 150KN, accuracy +/- 1%, digital pressure gauge directly displays shear force, light structure, easy operation, suitable for masonry shear strength detection.

$960.00
SE
TIANDIXINGHUO XH-BZQ inverse reflection standard
Suitable for calibrating Retroreflectometer (reverse reflection mark Measurement Instrument, reverse reflection mark Measurement Instrument, protruding road mark Measurement Instrument)

$679.00
SE
KOSON KS-75 In-situ double shear instrument, masonry shear strength Detector 75KN thrust
Hydraulic driven by manual pump, rated thrust 75KN, accuracy +/- 1%, digital pressure gauge directly displays shear force, lightweight structure, suitable for masonry shear strength detection.

$2305.00
SE
CHINA BLD-CJ20D Hard Hat Impact Piercing
Microcomputer automatic control, drop hammer and puncture hammer free replacement, the bottom is equipped with a level test device, using the form of free fall.

$2422.00
SE
China BLD-ZD50 Bags Oscillation Impact performance testing machine QB/T2922
Impact height 0~ 150mm adjustable, test speed adjustable (0~ 40) cpm, oscillation times 1~ 999999 adjustable, with automatic recording and memory functions.

$128.00
SE
PUSHEN PVC vinyl sheet, black plastic sheet coating stain resistance test
Gloss (60 °) < 10 (measured value: 6 +/- 0.5), reflectance < 4% (measured value: 3 +/- 0.5) can replace the asbestos-free cement pressure plate used in the determination of architectural coatings scrub resistance, smooth matte surface, no plasticizer.

$6110.00
Huicheng HCDR-P Plate Thermal Conductivity Instrument Temperature resolution 0.01 ℃
Thermal conductivity range 0.0020~2.0000 W/(m · K), resolution 0.0001 W/(m · K), Hot Plate Temperature range RT + 10~100 ℃, Cold Plate Temperature range RT~ 80 ℃, Hot Plate temperature control accuracy +/- 0.02 ℃, Temperature resolution 0.01 ℃, thickness resolution 0.01mm

$6063.00
SE
HUITAO HT-554A glove linear cutting resistance performance Tester
Test gloves cutting performance, the total load can reach 61N, load range 0.1~ 200N, LCD panel visual display test data.

Login
DZDR-AS transient method thermal conductivity Tester, transient plane heat source method
Using the international standard transient plane heat source method (ISO 2 2007-2, etc.), it can quickly (≤ 160 seconds) and accurately (accuracy 0.0001W/(m · K)) measure the thermal conductivity of various materials (solid, liquid, powder, etc.).

$618.00
SE
DUBAN DB25-ATP-A6 ATP Fluorescence Bacteria Detector (High Sensitivity)
Detection accuracy 1X10-16mol ATP (high sensitivity type), detection limit ≤ 1.0 CFU/ml, detection range ORLU~ 9999 RLU (relative luminescence unit), coliform ≥ 1 × 10 CFU, detection time 1 second -60 seconds, detection interference +/- 5% or +/- 5 RLUs, background value ≤ 1RLU, detection mode RLU or coliform screening, can set the limit number 1000 or more, storage size 3000 or more.

$3476.00
SE
CHINA BLD-WF10C luggage reciprocating fatigue testing machine
Made of high-strength aluminum alloy, the test position can adjust the test stroke, the tensile speed is 0~30cm/sec, and the reciprocating fatigue test is done for the tie rod of the bag.

$849.00
SE
KOSON KS-75S intelligent in-situ double shear instrument, masonry Detector 75KN thrust, Bluetooth printing
Hydraulic drive, rated thrust 75KN, accuracy +/- 1%, with 2.8 inch touch screen, support Bluetooth printing and computer online, can store 200,000 detection data.

Login
DZ3500S carbon black content Tester, high temperature pyrolysis carbon black content Tester
Using high temperature pyrolysis technology, accurate temperature control (room temperature~ 1150 ° C), 7-inch touch screen one-button operation, support multi-stage program heating and automatic calculation results. Integrated design with rapid cooling (≤ 20 minutes) and exhaust gas filtrate function, 4 samples can be measured at a time.

Login
DZDR-S Thermal Conductivity Tester, Transient Plane Heat Source Method (TPS)
Transient planar heat source method (TPS) for fast and accurate measurement of thermal conductivity of various materials (metals, Pottery and porcelain, polymers, composites, etc.) (0.0001-300W/(m · K)).

Login
DZ-DSC300L Differential Scanning Calorimeter -170 ℃~ 600 ℃
Using industrial-grade 7-inch touch screen operation, temperature range covering -170 ° C to 600 ° C, sensitivity (0.001mW) and Accuracy (0.001 ° C), suitable for a variety of refrigeration devices, three-way atmosphere automatic switching, PID intelligent temperature control, fault self-test protection function.

$3083.00
SE
HUITAO CSI-SX48 automatic crease recovery Tester, fiber fabric folding recovery detection
Equipped with 4 standard weights (2000g to 200kg) and precision spiral column structure, 15cm × 28cm samples can be uniformly pressurized for testing, 12 samples can be continuously detected within 5 minutes, and multi-angle data recording is supported.

$3059.00
SE
PUSHEN SYW-I residue on sieve Tester 45 μm sieve aperture
70R/min Rotation speed with 45 μm sieve pore size, suitable for the determination of powder particles dispersed or insoluble in water, in line with many international standards.

$581.00
SE
QIWEI QW-SZF-06A fat measuring instrument
Using digital electric heating constant temperature Water Bath heating, Temperature range + 5 to 100 ℃, can process 6 samples at the same time, Glass grinding connection to ensure good sealing, operation saving time and effort.

Login
DSC400 Differential Scanning Calorimeter RT-600 ℃
Using imported E-type Sensors, with ultra-high sensitivity (0.001mW) and Accuracy (0.001 ℃), temperature range RT-600 ℃, can accurately determine the melting point, Glass transition temperature, specific heat capacity and other parameters.

$485.00
SE
QIWEI QW-KDN type, Kjeldahl nitrogen meter distillation device, automatic nitrogen measurement distillation system
Using Kjeldahl principle, measuring range of 0.1~ 200mgN, collection rate ≥ 99%. Automatic water, alkali and distillation functions, easy to operate, suitable for a variety of sample detection.

$247.00
SE
QIWEI QW-NSY-12ST (timing) sample condensing instrument, air drying instrument 12 holes PID temperature control
Timing, 12-hole independent blowpipe design to avoid cross-contamination, PID temperature control accuracy +/- 0.3 ℃, with its own air source to achieve 0-36L/min Flow rate adjustment, compact body suitable for a variety of environments.

If you don't know how to choose "Miscellaneous instruments", please consult customer service.