Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Type:Fixed >

      Gas detector

      390 results
      Featured Hot Price Time
      GUOYUGRA GY/VGD-200-NOX-G (0-20ppm) high performance, nitrogen oxide Detector
      $644.00 SE
      GUOYUGRA GY/VGD-200-NOX-G (0-20ppm) high performance, nitrogen oxide Detector
      NOX0-20Pm (optional 50ppm, 100ppm, 200ppm)diffusion
      High performance, flue gas online detection and analysis, only NO or NO2 is measured, and the sum of the measurements requires NO + NO2 + O2 conversion values (three Sensors), and supports wireless transmission (such as LORA, 4G, WiFi, etc.).
      Compare
      GUOYUGRA GY/VGD-200-C2H6O-G (0-10ppm) Dimethyl Ether Detector
      $898.00 SE
      GUOYUGRA GY/VGD-200-C2H6O-G (0-10ppm) Dimethyl Ether Detector
      C2H6O0-10Pm (optional 50ppm, 100ppm, 1000ppm, 5000ppm)diffusion
      Conventional, leak detection, optional PID, high-precision intelligent Sensors and low-power MCU chip design, high definition LCD display and local sound and light alarm function, flameproof aluminum alloy shell, through a number of international safety certifications.
      Compare
      Empaer AATL-O2 (Pump Suction) Pathfinder Series Fixed Oxygen Detector
      $732.00 SE
      Empaer AATL-O2 (Pump Suction) Pathfinder Series Fixed Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, error of indication 1%, Repeatability 3% FS, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Response time T90 ≤ national standard
      Compare
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      $272.00 SE
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA.
      Compare
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      $323.00 SE
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, storage temperature -10 ° C~ 30 ° C, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ° C~ 55 ° C; Operating humidity: 10% -95% RH (no condensation), support zero automatic correction, suitable for multiple industries.
      Compare
      Empaer AATL-O2 (4G) Pathfinder Series Stationary Oxygen Detector
      $436.00 SE
      Empaer AATL-O2 (4G) Pathfinder Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-O3 (4G) Volkswagen Series Fixed Ozone Detector
      $705.00 SE
      Empaer APEG-D-O3 (4G) Volkswagen Series Fixed Ozone Detector
      O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, please contact the customer service of the mall.
      Detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CO2 Volkswagen Series Stationary Carbon Dioxide Detector
      $864.00 SE
      Empaer APEG-D-CO2 Volkswagen Series Stationary Carbon Dioxide Detector
      CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias CO2, detection range 0~5000ppm, remote wireless output alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      $296.00 SE
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2S, detection range 0-500ppm, power supply mode 12~ 36VDC (typical power supply 24VDC), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃, support zero automatic correction
      Compare
      Empaer APEG-D-CO2 (4G) Volkswagen Series Stationary Carbon Dioxide Detector
      $976.00 SE
      Empaer APEG-D-CO2 (4G) Volkswagen Series Stationary Carbon Dioxide Detector
      CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CO2 (4G) Pathfinder Series Stationary CO2 Detector
      $1011.00 SE
      Empaer AATL-CO2 (4G) Pathfinder Series Stationary CO2 Detector
      CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)
      Compare
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      $387.00 SE
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CH2O Pathfinder Series Fixed Formaldehyde Detector
      $603.00 SE
      Empaer AATL-CH2O Pathfinder Series Fixed Formaldehyde Detector
      CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CH2O, detection range 0~10ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA
      Compare
      Empaer AATL-H2 (sound and light alarm) Pathfinder series stationary hydrogen Detector
      $334.00 SE
      Empaer AATL-H2 (sound and light alarm) Pathfinder series stationary hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-O3 (4G) Pathfinder Series Fixed Ozone Detector
      $738.00 SE
      Empaer AATL-O3 (4G) Pathfinder Series Fixed Ozone Detector
      O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      $352.00 SE
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CO2 (sound and light alarm) Pathfinder series stationary carbon dioxide Detector
      $921.00 SE
      Empaer AATL-CO2 (sound and light alarm) Pathfinder series stationary carbon dioxide Detector
      CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CL2 Pathfinder Series Stationary Chlorine Detector
      $398.00 SE
      Empaer AATL-CL2 Pathfinder Series Stationary Chlorine Detector
      CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CL2, detection range 0~50ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, can control peripherals, full alarm reminder function
      Compare
      Empaer APEG-D-O2 (4G) Volkswagen Series Stationary Oxygen Detector
      $403.00 SE
      Empaer APEG-D-O2 (4G) Volkswagen Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-30% VOL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CL2 (4G) Volkswagen Series Stationary Chlorine Detector
      $477.00 SE
      Empaer APEG-D-CL2 (4G) Volkswagen Series Stationary Chlorine Detector
      CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CH2O (sound and light alarm) Pathfinder series Fixed Formaldehyde Detector
      $625.00 SE
      Empaer AATL-CH2O (sound and light alarm) Pathfinder series Fixed Formaldehyde Detector
      CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CH2O, detection range 0~10ppm, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      $376.00 SE
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      $277.00 SE
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-H2 (4G) Volkswagen Series Stationary Hydrogen Detector
      $392.00 SE
      Empaer APEG-D-H2 (4G) Volkswagen Series Stationary Hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      $296.00 SE
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, support zero automatic correction, IP66 protection
      Compare
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      $319.00 SE
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, detection accuracy is better than the national standard accuracy, generally ≤ +/- 3% FS, error of indication 3% FS, Repeatability 1%, storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-O3 Pathfinder Series Stationary Ozone Detectors
      $625.00 SE
      Empaer AATL-O3 Pathfinder Series Stationary Ozone Detectors
      O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias O3, detection range 0~100ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA
      Compare
      Empaer AATL-CO2 (Pump Suction) Pathfinder Series Stationary Carbon Dioxide Detector
      $1305.00 SE
      Empaer AATL-CO2 (Pump Suction) Pathfinder Series Stationary Carbon Dioxide Detector
      CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-EX Volkswagen Series Fixed Gas Detector
      $239.00 SE
      Empaer APEG-D-EX Volkswagen Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, automatic calibration zero automatic correction function
      Compare
      Empaer AATL-O3 (sound and light alarm) Pathfinder series fixed ozone Detector
      $647.00 SE
      Empaer AATL-O3 (sound and light alarm) Pathfinder series fixed ozone Detector
      O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O3, detection range 0~100ppm, sound and light alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, error of indication 3% FS
      Compare
      If you don't know how to choose "Gas detector", please consult customer service.
      Focus on online sales of Lab Testing Instruments