$556.00
SE
Empaer APEG-D-CH2O Volkswagen Series Fixed formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias CH2O, detection range 0~10ppm, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$700.00
SE
Empaer AATL-CH2O (4G) Pathfinder Series Fixed Formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$989.00
SE
Empaer AATL-CH2O (Pump Suction) Pathfinder Series Fixed Formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH2O, detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$567.00
SE
Empaer AASD-CH2O Lightning Series Handheld Formaldehyde Detector
CH2O0~10ppm
Gas name and alias CH2O, detection range 0~10ppm, using mode diffusion type, use mode handheld, neck hanging type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$668.00
SE
Empaer APEG-D-CH2O (4G) Volkswagen Series Fixed formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$545.00
SE
Empaer SPES-CH2O solitary series handheld formaldehyde concentration Detector
CH2O0~10ppm
Detection gas type CH2O, detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$590.00
SE
Empaer AATL-CH2O Pathfinder Series Fixed Formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH2O, detection range 0~10ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$612.00
SE
Empaer AATL-CH2O (sound and light alarm) Pathfinder series Fixed Formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH2O, detection range 0~10ppm, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

If you don't know how to choose "Gas detector", please consult customer service.