Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Type:Fixed >

      Gas detector

      GUOYUGRA GY/VGD-200-PH3-G (0-5ppm) phosphating hydrogen Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-PH3-G (0-5ppm) phosphating hydrogen Detector
      PH30-5 ppm (optional 20ppm, 50ppm, 100ppm)diffusion
      Using advanced catalytic combustion detection principle, with low-power MCU chip and intelligent Sensors, support a variety of signal output methods, in line with strict explosion-proof standards.
      Compare
      GUOYUGRA GY/VGD-200-CL2-G (0-10ppm) Chlorine Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-CL2-G (0-10ppm) Chlorine Detector
      CL20-10Pm (optional 20ppm, 50ppm, 200ppm)diffusion
      Using advanced catalytic combustion detection principle, with high Sensitivity and accuracy, suitable for chlorine leakage monitoring in industrial environments, easy to connect with PLC, DCS and other Control systems.
      Compare
      GUOYUGRA GY/VGD-200-SO2-G (0-20ppm) sulfur dioxide Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-SO2-G (0-20ppm) sulfur dioxide Detector
      SO20-20ppm (optional 50ppm, 100ppm)diffusion
      Leak detection, can not be used in the flue gas environment, intelligent Sensors and MCU chips, support a variety of signal output methods, but also support wireless data transmission (such as LORA, 4G, WiFi, etc.).
      Compare
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) High Temperature Combustible Gas Detector
      $369.00 SE
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) High Temperature Combustible Gas Detector
      Ex0-100%LEL、5%Voldiffusion
      High temperature within 260 degrees, Anti-Impact poisoning, catalytic combustion detection principle and intelligent MCU chip, Sensors life of 2 to 3 years, high definition LCD LCD screen, Chinese and English interface switching and remote control adjustment function.
      Compare
      GUOYUGRA GY/VGD-200-NO-G (0-20ppm) nitric oxide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-NO-G (0-20ppm) nitric oxide Detector
      NO0-20Pm (optional 50ppm, 100ppm, 250ppm)diffusion
      Leak measurement, can not be used in flue gas environment, using catalytic combustion principle, low power MCU chip and intelligent Sensors technology, with aluminum alloy explosion-proof housing and sound and light alarm function.
      Compare
      Empaer AATL-O2 (sound and light alarm) Pathfinder series fixed oxygen Detector
      $338.00 SE
      Empaer AATL-O2 (sound and light alarm) Pathfinder series fixed oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃, Operating humidity: 10% -95% RH (no condensation)
      Compare
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      $290.00 SE
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2S, detection range 0-500ppm, power supply mode 12~ 36VDC (typical power supply 24VDC), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃, support zero automatic correction
      Compare
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      $368.00 SE
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      $316.00 SE
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, storage temperature -10 ° C~ 30 ° C, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ° C~ 55 ° C; Operating humidity: 10% -95% RH (no condensation), support zero automatic correction, suitable for multiple industries.
      Compare
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      $267.00 SE
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA.
      Compare
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      $312.00 SE
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, detection accuracy is better than the national standard accuracy, generally ≤ +/- 3% FS, error of indication 3% FS, Repeatability 1%, storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      $344.00 SE
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      $378.00 SE
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      $290.00 SE
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, support zero automatic correction, IP66 protection
      Compare
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      $271.00 SE
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-H2S (4G) Volkswagen series stationary hydrogen sulfide Detector
      $368.00 SE
      Empaer APEG-D-H2S (4G) Volkswagen series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-H2S Volkswagen series stationary hydrogen sulfide Detector
      $256.00 SE
      Empaer APEG-D-H2S Volkswagen series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias H2S, detection range 0-500ppm, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, automatic calibration zero automatic correction function
      Compare
      Empaer APEG-D-CH4 Volkswagen Series Stationary Methane Detector
      $234.00 SE
      Empaer APEG-D-CH4 Volkswagen Series Stationary Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias CH4, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CO Volkswagen Series Stationary Carbon Monoxide Detector
      $256.00 SE
      Empaer APEG-D-CO Volkswagen Series Stationary Carbon Monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, remote wireless output alarm;
      Compare
      Empaer APEG-D-O2 Volkswagen Series Stationary Oxygen Detector
      $282.00 SE
      Empaer APEG-D-O2 Volkswagen Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, automatic calibration zero automatic correction function, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-H2 Pathfinder Series Stationary Hydrogen Detectors
      $305.00 SE
      Empaer AATL-H2 Pathfinder Series Stationary Hydrogen Detectors
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA
      Compare
      Empaer AATL-CH4 Pathfinder Series Fixed Methane Detector
      $267.00 SE
      Empaer AATL-CH4 Pathfinder Series Fixed Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias CH4, detection range 0~100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA
      Compare
      Empaer APEG-D-EX Volkswagen Series Fixed Gas Detector
      $234.00 SE
      Empaer APEG-D-EX Volkswagen Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, automatic calibration zero automatic correction function
      Compare
      Empaer AATL-EX (sound and light alarm) Pathfinder series fixed Gas Detector
      $290.00 SE
      Empaer AATL-EX (sound and light alarm) Pathfinder series fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CL2 Volkswagen Series Stationary Chlorine Detector
      $357.00 SE
      Empaer APEG-D-CL2 Volkswagen Series Stationary Chlorine Detector
      CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias CL2, detection range 0~50ppm, automatic calibration zero automatic correction function, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CH4 (Sound and Light Alarm) Pathfinder Series Fixed Methane Detector
      $290.00 SE
      Empaer AATL-CH4 (Sound and Light Alarm) Pathfinder Series Fixed Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CH4, detection range 0~100% LEL, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-H2S (sound and light alarm) Pathfinder series fixed hydrogen sulfide Detector
      $312.00 SE
      Empaer AATL-H2S (sound and light alarm) Pathfinder series fixed hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2S, detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-CH4 (4G) Volkswagen Series Stationary Methane Detector
      $344.00 SE
      Empaer APEG-D-CH4 (4G) Volkswagen Series Stationary Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-H2 (sound and light alarm) Pathfinder series stationary hydrogen Detector
      $327.00 SE
      Empaer AATL-H2 (sound and light alarm) Pathfinder series stationary hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, sound and light alarm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-EX (4G) Pathfinder Series Stationary Gas Detector
      $378.00 SE
      Empaer AATL-EX (4G) Pathfinder Series Stationary Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), full alarm and anti-misoperation, zero self-correction; waterproof and anti-interference, bilingual switching
      Compare
      If you don't know how to choose "Gas detector", please consult customer service.
      Focus on online sales of Lab Testing Instruments