$616.00
SE
Empaer AATL-SO2 Pathfinder Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$695.00
SE
Empaer AATL-CO (Pump Suction) Pathfinder Series Stationary Carbon Monoxide Detectors
CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO, detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$695.00
SE
Empaer AATL-H2S (pump suction) pathfinder series stationary hydrogen sulfide Detector
H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias H2S, detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$673.00
SE
Empaer AATL-CH4 (Pump Suction) Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$503.00
SE
Empaer AATL-CL2 (4G) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$638.00
SE
Empaer AATL-SO2 (sound and light alarm) Pathfinder series fixed sulfur dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, please consult the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, sound and light alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$673.00
SE
Empaer AATL-EX (Pump Suction) Pathfinder Series Fixed Gas Detector
EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias EX, detection range 0-100% LEL, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

If you don't know how to choose "Gas detector", please consult customer service.