$179.00
SE
IWAVE WH91 split coating Film thickness meter Iron base
magnetic induction0 ~ 1250µmZero point calibrated ± (1 + 3% H); two point calibrated ± [ (1%~ 3% H) ] H + 1.5
Iron-based Coating Thickness Gauge, thickness 0~1250 microns, error of +/- 3%, magnetic thickness measurement principle, in line with GB/T and JJG standards, with single point and two points Calibration method.

$1513.00
SE
Defelsko PosiTector 6000 FRS3 Coating Thickness Gauge 90 ° probe
Magnetic Induction0~1500μm±1%
90 degree magnetic Induction probe, used for low headroom area thickness measurement, waterproof probe can be underwater measurement; support usb/bluetooth/wifi communication interface; can flip the display touch LCD screen; with real-time drawing measurement data, batch processing mode, three scanning modes.

$1756.00
SE
Defelsko PosiTector 6000 FLS1 Coating Thickness Gauge for thick coatings
Magnetic Induction0~38000μm±3%
Thick coating thickness measurement special, 38mm ultra-thick range, thick protective coating measurement, such as epoxy, fire-proof coatings, etc.

$1266.00
SE
Defelsko PosiTector 6000 FN1 Coating Thickness Gauge for automatic substrate type and measurement
Magnetic Induction + eddy Current0~1500μm±1%
Magnetic Induction and eddy Current thickness measurement principle, range 0~1500μm, accuracy +/- 1%, integrated FN probe, 2.8-inch color touch screen, screen image saving 100, can store 1000 readings.

$1150.00
SE
Defelsko PosiTector 6000 FKS1 Coating Thickness Gauge for coatings
Magnetic Induction0~13000μm±3%
Standard magnetic Induction thickness measurement, with FKS split thickness coating probe, thickness measurement range 0~13000 μm, error +/- 3%, with calibrated certificate, 2.8 inch color touch screen, supporting software PosiSoft.

$254.00
SE
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction, eddy CurrentF: 0~1500μm; N: 0~1500μm of which: Chromium plating on copper (0~40μm)±3%
Split, magnetic Induction eddy Current dual-use thickness measurement method, can store 500 Measured values, unique temperature compensation algorithm.

Login
Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
Magnetic Induction + eddy CurrentFe:0~5000μm;NFe:0~3000μm±3%

$312.00
SE
DONGRU DR6000 Anticorrosive layer Thickness Gauge 0~6000μm
Magnetic Induction0 ~ 6000μm±3%

Login
Leeb210 coated Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
magnetic induction0 ~ 1250µm±3%
Magnetic induction thickness measurement principle, thickness measurement range 0~1250μm, accuracy ± 3%, with single and continuous measurement, support a variety of calibrating methods, no supporting software.

$332.00
SE
DONGRU DR9000S anticorrosive layer Thickness Gauge 0~9500μm
Magnetic Induction0 ~ 9500µm±3%

Login
LEEB242 (F1) paints Thickness Gauge with external magnetic probe
magnetic induction0 ~ 1250µm±3%

Login
German EPK MiniTest 600 B-FN coated platings Thickness Gauge, iron-based/non-iron-based
Magnetic Induction + eddy Current0~2000μm±2%
For iron-based and non-iron-based coatings thickness measurement, with wire probe, to meet the different metal substrate measurement, thickness measurement range of 0~2000μm, error +/- 2%, in line with ISO, DIN, BS, ASTM standards.

$164.00
SE
IWAVE WH-81 Coating Thickness Gauge magnetic thickness measurement method 0~1250μm
Magnetic Induction0~1250μm±3%
Measurement range 0~1250μm, error range +/- 3%, can quickly and accurately detect the thickness of coatings.

$413.00
SE
DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Magnetic eddy current dual-use Film Thickness Gauge, thickness range 0~1250 microns, error accuracy +/- 1~ 3%, with zero, two, multi-point calibrated, can store 2000 data, using imported high-quality metal probe.

$245.00
SE
Linshang LS221 Coating Thickness Gauge Fe/NFe 2000μm
Magnetic induction + eddy current0 ~ 2000m±3%
Reaction time 0.5s; Aluminum dual function; Measurement; Split probe; Range 0-2000um; Error range ± (3% + 2um of reading); Minimum matrix Film thickness Fe0.2mm/NFe0.05mm.

$304.00
SE
DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
Magnetic Induction0 ~ 1250µm±3%
Magnetic Induction measurement, built-in probe, thickness measurement range 0~1250μm, error accuracy +/- 3%, with statistical function, single and continuous measurement, can store 116 data, can be connected to computer printing data.

$790.00
SE
Qnix 5500 Coating Thickness Gauge
Magnetic Induction + eddy Current (depending on probe)

$599.00
SE
Coating Thickness Gauge AMITTARI AC-112H Special magnetic Induction Coating Thickness Gauge
magnetic induction0 ~ 12000μ m±3%
Magnetic Induction coating thickness measurement, thickness measurement range 0~12000μm, error +/- 3%, suitable for thick coatings such as anti-corrosion coatings thickness measurement, data can be transmitted through USB connection.

$288.00
SE
KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
Magnetic Induction0~1250μm±2%
Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, probe contact parts plated hard chrome or ruby, durable, with automatic identification probe function, for measurement of magnetic metal substrate on the nonmagnetic Coating thickness.

$265.00
SE
AMITTARI AC-110MC Integrated Coating Thickness Gauge Dual function Film Thickness Gauge 0~500μm
± 1 ~ 5% / ± 3.5µm
Standard test range 0~500um/0~20mil, resolution 0.1μm | 1μm, error range +/-1~ 5 %/ +/- 3.5μm, thinnest substrate 0.3mm

$265.00
SE
AMITTARI AC-990 Coating Thickness Gauge dual function, thickness measurement range 0~500um
Magnetic induction + eddy current0 ~ 500µm±3%
Magnetic Induction + eddy Current, Measurement range 0~500μm, error range +/- 3%, resolution 0.1μm | 1μm, minimum measurement surface φ 26mm, meet the standards ISO2178, ISO2360, GB4956, GB4957

$341.00
SE
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic eddy current dual function, thickness measurement accuracy +/- 3%; automatic memory calibrated value, optional RS-232C/USB/Bluetooth data processing interface.

$341.00
SE
AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
Magnetic induction + eddy current0 ~ 1250µm±3%
Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.

$506.00
SE
Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.

$285.00
SE
DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1000µm±3%
Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

Login
PHYNIX Surfix SX-F0.5A iron-based micro probe coated platings Thickness Gauge 500μm
Magnetic Induction + eddy Current0-500μm
The measurement probe is made of cemented carbide, the measurement probe is large, the measurement is stable, no need to calibrate, and the statistical parameters such as the actual measurement value and the average value can be realized.

$506.00
SE
Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

Login
Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
magnetic induction0 ~ 1250µm±3%
Magnetic induction thickness measurement principle, measurement of magnetic metal substrate coated Film thickness, thickness measurement range 0~1250μm, accuracy ± 3%, the thinnest substrate 0.5mm, data storage 500 measurement values.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.