$489.00
SE
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$652.00
Germany QNix4200 Integrated magnetic Induction Coating Thickness Gauge 3mm range
magnetic Induction0~3000μm±3%
Range 0~3000 microns; integrated built-in iron-based probe, the probe material is ruby; no need to calibrate.

$568.00
SE
LANDTEK CM-1210-200F Coating Thickness Gauge
0 ~ 200 μm
Magnetic metal substrate thickness measurement, split structure, thickness measurement range 0~200μm, Precision +/- 1~ 3% n or +/- 2.5μm, with single and continuous thickness measurement mode, dedicated to coating measurement on small workpieces.

$350.00
SE
DONGRU DR330 Coating Thickness Gauge measurement of metal surface platings
Magnetic Induction + eddy Current0 ~ 1250µm±3%
Magnetic Induction and eddy Current dual function, thickness range 0~1250μm, error accuracy +/- 3%, with statistical function, measurement of metal surface coating thickness, can store 116 Measured values.

$234.00
SE
IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.

$927.00
QNix4200/5 magnetic Induction Coating Thickness Gauge 0-5000um
magnetic Induction0~5000μm±3%

$1534.00
SE
QNix 9500Pro + Coating Thickness Gauge host, enhanced + type
Magnetic Induction + eddy Current (depending on probe)Determined by the probe
Thickness Gauge host, probe needs to be purchased separately. Support a variety of Calibration methods, can store 2000000 readings, the display screen can be turned over from multiple angles, and the shell contains fiberglass.

$873.00
SE
Linshang LS225 Coating Thickness Gauge with F500 Magnetic Probe + Test Fixture
magnetic induction0.0 ~ 500µm± (0.3 μm + 2%) five-point calibrated
Magnetic induction, split probe, range 0-500um, error range ± (2% of reading + 0.3um); Minimum matrix Film thickness 0.1mm; Equipped with test fixture, the repeability can reach 0.1um; Small size/special-shaped material can be measured.

$245.00
SE
Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
Coating Thickness Gauge host, support zero adjustment and multi-point calibrating, with temperature compensation function, with data statistics function, need to buy another probe, can be matched with rack test.

$683.00
SE
Defelsko FS conventional strip probe 0~1500μm/non-ferrous metal
Magnetic Induction0~1500μm±1%

$371.00
SE
IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.

Login
PHYNIX Surfix SX-F1.5 magnetic Film Thickness Gauge 1500μm
Magnetic Induction0~1500μm±1μm/2%
Magnetic Induction, measurement range 0~1500μm, error range +/- 1μm/2%, resolution 0.1μm, supports multiple operating languages, supports USB data transfer, can store up to 2,000 measurement values.

$404.00
SE
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.

$173.00
SE
LINSHANG LS237 Film Thickness Gauge (for automobile paint thickness detection)
Iron: Hall Effect/Aluminum: eddy Current0.0-3500μm≤ +/- ( 3% H + 2 μm) H is the Standard value
Measurement range 0.0-3500 μm, Measurement accuracy ≤ +/- ( 3% H + 2 μm), the use of hard wear-resistant ruby probe to reduce measurement errors, digital signal processing is completed directly on the probe to ensure data stability throughout the measurement process.

$344.00
SE
LINSHANG LS226 Coating thickness gauge Iron non-iron dual-use probe 0.0-2000 μm Measurement range
Fe: magnetic Induction NFe: eddy Current0.0-2000μm
Measurement accuracy up to 2% H + 1μm, support continuous measurement function, 0.1 second fast data acquisition, built-in memory chip can save 9 sets of data, minimum matrix thickness Fe: 0.2mm/NFe: 0.05mm.

Login
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Magnetic Induction + eddy Current0~1250μm±3%
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.

$169.00
SE
LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
Magnetic Induction + eddy Current0~2000μm±3%
It can measure the thickness in a low temperature environment at minus 40 ℃, the thickness measurement range is 0.0-2000 μm, the built-in integrated dual-function probe has an error range of +/- 3%, and has the function of temperature compensation and digitalization of analog signal terminals.

Login
PHYNIX Surfix Easy x I-FN HR dual-use Film Thickness Gauge 3000 μm
Magnetic Induction + eddy Current10~3000μm±2μm/2%
Magnetic Induction + eddy Current, measurement range 10~3000μm, error range +/- 2μm/2%, resolution 0.1μm, with 3000μm measurement range, free calibrated measurement, backlight display, one key calibrated, online statistics, sound signal when recording readings and many other functions.

Login
PHYNIX Surfix Easy x I-F HR Iron-based Coating Thickness Gauge 300μm
Magnetic Induction10~3000μm±2μm/2%
Magnetic Induction, measurement range 10~3000μm, error range +/- 2μm/2%, resolution 0.1μm, with free calibrated measurement, online statistics, backlight display and other functions.

$2830.00
SE
German EPK MiniTest 735 F15 Film Thickness Gauge thickness 0~15000 μm
Magnetic Induction0~15000μm±0.75%

$2424.00
BoutiqueSE
Germany EPK MikroTest NiFe50 McCourt Eletroplating Nickel Thickness Gauge, Thickness Measurement: 0~50μm
mechanical0~50μm±8%

$975.00
SE
Germany EPK MikroTest S5 McCourt coated platings Thickness Gauge, thickness measurement: 0.5~ 5mm
mechanical500~5000μm±5%

$975.00
SE
Germany EPK MikroTest S3 McCourt coated platings Thickness Gauge, thickness measurement: 0.2~ 3mm
mechanical200~3000μm

$1787.00
SE
German EPK MiniTest 735 F5 iron-based Thickness Gauge, measuring thickness 0~5000μm
Magnetic Induction0~5000μm±0.75%

$2675.00
SE
Germany EPK MikroTest S20 McCourt enamel layer Thickness Gauge, thickness measurement: 7.5~ 20mm
mechanical7500~20000μm±5%

$173.00
SE
IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic and eddy Current dual-function Thickness Gauge, thickness range 0~1250μm, error +/- 3%, integrated structure, in line with a variety of GB/T and JB/T standards, Appearance Compact and portable.

$1548.00
SE
List Magnetik Pocket TOP-CHECK FN Pocket platings Thickness Gauge
Magnetic Induction + eddy CurrentFe;0~5000μm;NFe;0~2000μm±1μm/±1~5%

$1501.00
SE
List Magnetik Pocket TOP-CHECK FE-B Pocket platings Thickness Gauge
magnetic Induction0~5000μm±1μm/±1~5%

$1159.00
SE
List Magnetik Pocket TOP-CHECK FE Pocket platings Thickness Gauge
magnetic Induction0~5000μm±1μm/±1~5%

$1563.00
SE
List Magnetik MEGA-CHEK Pocket FE platings Thickness Gauge
magnetic Induction0~5000μm±1μm/±1~5%

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.