LANDTEK CM8820 Coating Thickness Gauge paints Film Thickness Gauge
magnetic induction0 ~ 2000m±5%
Magnetic Induction Thickness Measurement Principle, Thickness Measurement Range 0~2000μm, Accuracy Error +/- 5%, F Split Probe, for measurement of the thickness of non-magnetic conductive coatings on ferromagnetic metal substrates, no supporting software.

Login
Germany Knix QNix4500 dual-use Coating Thickness Gauge integrated probe 3mm range
Magnetic Induction + eddy CurrentFe:0~3000μm; NFe:0~3000μm±3%

$234.00
SE
LANDTEK CM8821 Coating Thickness Gauge measurement of non-magnetic conductive coatings on ferromagnetic metal substrates
magnetic induction0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000μm; External probe, magnetic Induction; Low Voltage prompt; USB and Bluetooth data output can be purchased separately.

Login
Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
Magnetic Induction + eddy CurrentFe:0~5000μm;NFe:0~3000μm±3%

Login
German EPK MiniTest 735 N0.7 eddy Current Thickness Gauge, Thickness 0~700μm
Eddy Current0~700μm±0.75%
Calibration method "rough" can avoid the problem of thickness measurement accuracy deviation caused by surface roughness; continuous measurement, with Bluetooth communication;

$599.00
SE
Coating Thickness Gauge AMITTARI AC-112H Special magnetic Induction Coating Thickness Gauge
magnetic induction0 ~ 12000μ m±3%
Magnetic Induction coating thickness measurement, thickness measurement range 0~12000μm, error +/- 3%, suitable for thick coatings such as anti-corrosion coatings thickness measurement, data can be transmitted through USB connection.

$341.00
SE
AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
Magnetic induction + eddy current0 ~ 1250µm±3%
Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.

$506.00
SE
Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.

$506.00
SE
Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

$455.00
SE
Defelsko PosiTest G Coating Thickness Gauge for Eletroplating, thin paint layer, steel phosphating film thickness measurement with certificate
Magnetic Induction0~200µm±5%
0~200µm dial type coated platings Thickness Gauge, no power supply, underwater testing, explosion-proof, can measure the surface sample Coating thickness.

$455.00
SE
Defelsko PosiTest F Mechanical Coating Thickness Gauge Explosion proof, underwater measurement with certificate
Magnetic Induction0~2000μm±5%
Pointer dial type, no power supply, safe explosion-proof, also suitable for underwater measurement of hot-dip galvanized, hard chrome, paints, enamel on steel and other film thickness, can easily measure cylindrical, factory comes with calibrated certificate.

$386.00
SE
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
Magnetic induction + eddy current0 ~ 1250µm±3%
Dual function thickness measurement, built-in probe, automatic identification of substrate; RS232 interface; automatic memory calibrating; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.

$2247.00
SE
German EPK MiniTest 735 F1.5 statistical coating Thickness Gauge, thickness measurement 0~1500μm
Magnetic Induction0~1500μm±0.75%
Split, external F1.5 probe, thickness measurement range is 0~1500μm, error range +/- 0.75%, with Bluetooth interface, support for a variety of Calibration methods, supporting software, can transmit data wirelessly.

$2636.00
SE
Germany EPK MiniTest 735 FN1.5 dual-use Film Thickness Gauge thickness 0~1500μm/0~700μm
Magnetic Induction + eddy Current0~1500μm(F)/0~700μm(N)±0.75%
Iron copper base dual-use measurable, 1.5mm range, continuous measurement, 10w Data storage , +/- 0.75% accuracy, Bluetooth wireless transmission belt software.

$675.00
SE
Positector SmartLink wireless connector, a new generation of detection methods
Intelligent wireless thickness measurement, can realize probe + connector + intelligent end point data sharing, can be used for thickness measurement and environment or surface profile detection, supporting free mobile app, probe optional.

$332.00
SE
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
Magnetic induction + eddy current0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
Eddy Current0~1250μm±3%
LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.

$257.00
SE
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
eddy current0 ~ 1000µm±3%
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.

$309.00
SE
LANDTEK CM8826f Coating Thickness Gauge magnetic Induction Coating Thickness Gauge platings/paints
Magnetic Induction0~1250μm±3%
LANDTEK mid-range practical type, external probe, magnetic Induction thickness measurement; RS232 interface; Single or continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; USB and Bluetooth data output can be purchased separately.

$346.00
SE
LANDTEK CM8820 (5mm Range) Cladding Thickness Gauge, Large Range Customized Type
magnetic induction0~5mm±5%
Measurement range 0~5mm, error range +/- 5%, resolution 0.1μm | 1μm, widely used in the measurement of steel, iron and other ferromagnetic metal substrates on non-ferrous magnetic coatings, platings.

$309.00
SE
LANDTEK CM8825F high-precision Coating Thickness Gauge, integrated magnetic Induction Coating Thickness Gauge
Magnetic Induction0~1250μm±3%
LANDTEK mid-range practical type, built-in probe, magnetic Induction principle; RS232 interface; automatic memory calibrating; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$386.00
SE
LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.

$386.00
SE
LANDTEK CM8828 Film Thickness Gauge for automotive coatings
Magnetic induction + eddy current0 ~ 1250µm±3%
Automotive coatings, built-in probe, double thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.

$386.00
SE
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.

$309.00
SE
LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, eddy Current principle; 1250μm; RS232 interface; automatic memory calibrating and identification substrate; RS232 interface; hand-held part groove design.

$309.00
SE
LANDTEK CM8829F magnetic Thickness Gauge, integrated F magnetic Induction Film Thickness Gauge
magnetic induction0 ~ 1250µm±3%
1250μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification substrate; statistical function, single and continuous Measurement mode; optional USB and Bluetooth data output.

$386.00
SE
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, dual function thickness measurement; Single and continuous two measurement modes; Automatic memory calibrating and identification substrate; RS232C interface; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.