$316.00
SE
DONGRU DR280 dual-use Coating Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%
Magnetic Induction and eddy Current dual-use Thickness Gauge, can measure the thickness of different metal substrates, thickness range 0~1250μm, error +/- 1~ 3%, no supporting software, support zero, two, multi-point calibrating.

$413.00
SE
DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Magnetic eddy current dual-use Film Thickness Gauge, thickness range 0~1250 microns, error accuracy +/- 1~ 3%, with zero, two, multi-point calibrated, can store 2000 data, using imported high-quality metal probe.

$304.00
SE
DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
Magnetic Induction0 ~ 1250µm±3%
Magnetic Induction measurement, built-in probe, thickness measurement range 0~1250μm, error accuracy +/- 3%, with statistical function, single and continuous measurement, can store 116 data, can be connected to computer printing data.

$285.00
SE
DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1000µm±3%
Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

$183.00
SE
DONGRU DR130 Coating Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1500m± (3% + 1.5µm)

$270.00
SE
DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
Magnetic Induction0 ~ 1250µm±1~3%
Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen

$350.00
SE
DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

$350.00
SE
DONGRU DR330 Coating Thickness Gauge measurement of metal surface platings
Magnetic Induction + eddy Current0 ~ 1250µm±3%
Magnetic Induction and eddy Current dual function, thickness range 0~1250μm, error accuracy +/- 3%, with statistical function, measurement of metal surface coating thickness, can store 116 Measured values.

$988.00
DONGRU DR200A concrete Coating thickness gauge Ultrasonic nondestructive Measurement Instrument
Measurement accuracy of 3% +/- 3μm with high frequency single crystal probe and automatic signal gain adjustment, range 40-1200μm, support delamination measurement and large capacity Data storage.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.