$326.00
SE
LANDTEK CM-1210A Coating Thickness Gauge 2000μm/+/- 3%
Magnetic induction + eddy current0~2000µm±1~3%/±2.5µm
Practical; 2000μm range; dual function; accuracy +/- (1μm + 3%); Single and continuous Measurement mode; with RS232 interface; optional Bluetooth output.

$316.00
SE
DONGRU DR280 dual-use Coating Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%
Magnetic Induction and eddy Current dual-use Thickness Gauge, can measure the thickness of different metal substrates, thickness range 0~1250μm, error +/- 1~ 3%, no supporting software, support zero, two, multi-point calibrating.

$231.00
SE
AMITTARI AC-990u paints Thickness Gauge, dual function, thickness measurement range 0~500μm
Magnetic induction + eddy current0 ~ 500µm±5%
Magnetic Induction + eddy Current, Measurement range 0~500μm, Error range +/- 5%, resolution 10μm, minimum measurement surface φ 26mm

$288.00
SE
KAIRDA NDT530 (N1) Zinc Coating Thickness Gauge with eddy Current Probe
Eddy Current0~1250μm±2%
Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, can be used to measure the thickness of nonconductive coatings on non-ferrous metal substrates.

$254.00
SE
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction, eddy CurrentF: 0~1500μm; N: 0~1500μm of which: Chromium plating on copper (0~40μm)±3%
Split, magnetic Induction eddy Current dual-use thickness measurement method, can store 500 Measured values, unique temperature compensation algorithm.

Login
LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
eddy current0 ~ 1250µm±3%
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1μm, widely used in chemical industry, light industry, Eletroplating, anti-corrosion, automotive, shipbuilding, aerospace, aviation, commodity inspection and other fields.

$245.00
SE
Linshang LS221 Coating Thickness Gauge Fe/NFe 2000μm
Magnetic induction + eddy current0 ~ 2000m±3%
Reaction time 0.5s; Aluminum dual function; Measurement; Split probe; Range 0-2000um; Error range ± (3% + 2um of reading); Minimum matrix Film thickness Fe0.2mm/NFe0.05mm.

$265.00
SE
AMITTARI AC-110MC Integrated Coating Thickness Gauge Dual function Film Thickness Gauge 0~500μm
± 1 ~ 5% / ± 3.5µm
Standard test range 0~500um/0~20mil, resolution 0.1μm | 1μm, error range +/-1~ 5 %/ +/- 3.5μm, thinnest substrate 0.3mm

$265.00
SE
AMITTARI AC-990 Coating Thickness Gauge dual function, thickness measurement range 0~500um
Magnetic induction + eddy current0 ~ 500µm±3%
Magnetic Induction + eddy Current, Measurement range 0~500μm, error range +/- 3%, resolution 0.1μm | 1μm, minimum measurement surface φ 26mm, meet the standards ISO2178, ISO2360, GB4956, GB4957

$341.00
SE
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic eddy current dual function, thickness measurement accuracy +/- 3%; automatic memory calibrated value, optional RS-232C/USB/Bluetooth data processing interface.

$341.00
SE
AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
Magnetic induction + eddy current0 ~ 1250µm±3%
Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.

$285.00
SE
DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1000µm±3%
Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

Login
Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
eddy current0 ~ 1250µm±3%
Coating Thickness Gauge, measurement of non-conductive coated Film thickness on non-metallic substrates, thickness measurement range 0~1250μm, accuracy ± 3%, one point calibrated mode, can store 500 measurement values.

$257.00
SE
DONGRU DR3000 dual-use Coating Thickness Gauge 0~3000μm
Magnetic Induction + eddy Current0 ~ 3000μ m±3%

Login
Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
eddy current0 ~ 1250µm±3%
1250 micron range, ± 3% error, eddy current thickness measurement; storage capacity 500 readings; limits can be set.

$234.00
SE
CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
±2%H+1μm
Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
±2%H+1μm
Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
±2%H+1μm
Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.

$265.00
SE
YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
±2%
Using magnetic Induction and eddy Current automatic conversion technology, Measurement range 0~3000μm, resolution 0.1μm, with super wear-resistant carbide probe, wear-resistant more than 500,000 times, Measurement speed 0.3 seconds/time.

$332.00
SE
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
Magnetic induction + eddy current0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
Eddy Current0~1250μm±3%
LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.

$350.00
SE
DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

$257.00
SE
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
eddy current0 ~ 1000µm±3%
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.

$309.00
SE
LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, eddy Current principle; 1250μm; RS232 interface; automatic memory calibrating and identification substrate; RS232 interface; hand-held part groove design.

$309.00
SE
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.

$234.00
SE
IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.

$245.00
SE
Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
Coating Thickness Gauge host, support zero adjustment and multi-point calibrating, with temperature compensation function, with data statistics function, need to buy another probe, can be matched with rack test.

$371.00
SE
IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.

Login
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Magnetic Induction + eddy Current0~1250μm±3%
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.