Login
PHYNIX Surfix SX-N1.5 non-ferrous paints Thickness Gauge 1500μm
Eddy Current0~1500μm±1μm/2%
Eddy Current, measurement range 0~1500μm, error range +/- 1μm/2%, resolution 0.1μm, minimum measurement surface 10x10mm, support USB data transfer, can store up to 2,000 measurement values.

$952.00
SE
German EPK MiniTest 600 B-N eddy current platings Thickness Gauge, thickness: 0~2000μm
Eddy Current0~2000μm±2%

Login
PHYNIX Surfix SX-FN1.5 dual-use Coating Thickness Gauge 1500μm
Magnetic Induction + eddy Current0~1500μm±1μm/2%
Magnetic Induction + eddy Current, measurement range 0~1500μm, error range +/- 1μm/2%, resolution 0.1μm, minimum measurement surface 10x10mm, colorful high-resolution color graphics display, support multiple operating languages.

Login
Germany Knix QNix4500 dual-use Coating Thickness Gauge integrated probe 3mm range
Magnetic Induction + eddy CurrentFe:0~3000μm; NFe:0~3000μm±3%

$1084.00
SE
QNix 9500 Coating Thickness Gauge, basic
Magnetic Induction + eddy Current (depending on probe)Determined by the probe
Contains fiberglass, waterproof/light/scratch/chemical; with three layers of shock protection, the screen can be swirled/spun 360 degrees; adapt to different probes.

Login
Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
Magnetic Induction + eddy CurrentFe:0~5000μm;NFe:0~3000μm±3%

Login
German EPK MiniTest 735 N0.7 eddy Current Thickness Gauge, Thickness 0~700μm
Eddy Current0~700μm±0.75%
Calibration method "rough" can avoid the problem of thickness measurement accuracy deviation caused by surface roughness; continuous measurement, with Bluetooth communication;

Login
German EPK MiniTest 600 B-FN coated platings Thickness Gauge, iron-based/non-iron-based
Magnetic Induction + eddy Current0~2000μm±2%
For iron-based and non-iron-based coatings thickness measurement, with wire probe, to meet the different metal substrate measurement, thickness measurement range of 0~2000μm, error +/- 2%, in line with ISO, DIN, BS, ASTM standards.

$790.00
SE
Qnix 5500 Coating Thickness Gauge
Magnetic Induction + eddy Current (depending on probe)

Login
PHYNIX Surfix SX-F0.5A iron-based micro probe coated platings Thickness Gauge 500μm
Magnetic Induction + eddy Current0-500μm
The measurement probe is made of cemented carbide, the measurement probe is large, the measurement is stable, no need to calibrate, and the statistical parameters such as the actual measurement value and the average value can be realized.

$2636.00
SE
Germany EPK MiniTest 735 FN1.5 dual-use Film Thickness Gauge thickness 0~1500μm/0~700μm
Magnetic Induction + eddy Current0~1500μm(F)/0~700μm(N)±0.75%
Iron copper base dual-use measurable, 1.5mm range, continuous measurement, 10w Data storage , +/- 0.75% accuracy, Bluetooth wireless transmission belt software.

$1226.00
SE
QNix 9500Pro Coating Thickness Gauge
Magnetic Induction + eddy Current (depending on probe)Determined by the probe
Thickness Gauge host, probe need to be purchased separately. With continuous Measurement mode and Pin code protection function, equipped with QN9 software, can be connected to PC online measurement, Protection level IP64.

$1534.00
SE
QNix 9500Pro + Coating Thickness Gauge host, enhanced + type
Magnetic Induction + eddy Current (depending on probe)Determined by the probe
Thickness Gauge host, probe needs to be purchased separately. Support a variety of Calibration methods, can store 2000000 readings, the display screen can be turned over from multiple angles, and the shell contains fiberglass.

Login
PHYNIX Surfix Easy x I-FN HR dual-use Film Thickness Gauge 3000 μm
Magnetic Induction + eddy Current10~3000μm±2μm/2%
Magnetic Induction + eddy Current, measurement range 10~3000μm, error range +/- 2μm/2%, resolution 0.1μm, with 3000μm measurement range, free calibrated measurement, backlight display, one key calibrated, online statistics, sound signal when recording readings and many other functions.

$1902.00
BoutiqueSE
German EPK MikroTest Ni100 McCourt coated platings Thickness Gauge, thickness measurement: 0~100μm
mechanical0~100μm±5%
Magnetic Induction thickness measurement principle, no need to calibrate, no power supply, measurement range 0~100μm, measurement accuracy of +/- (1μm + 5% of reading value), suitable for Eletroplating nickel on non-ferromagnetic metal substrates.

$1902.00
SE
German EPK MikroTest Ni50 McCourt Eletroplating Nickel Thickness Gauge, Thickness Measurement: 0~50μm
mechanical0~50μm±5%

$1548.00
SE
List Magnetik Pocket TOP-CHECK FN Pocket platings Thickness Gauge
Magnetic Induction + eddy CurrentFe;0~5000μm;NFe;0~2000μm±1μm/±1~5%

$1781.00
SE
List Magnetik MEGA-CHEK Pocket FN platings Thickness Gauge
Magnetic Induction + eddy CurrentFe;0~5000μm;NFe;0~2500μm±1μm/±1~5%

$1345.00
SE
Germany Nix QNix 4500 + FN5 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-5000μm
5mm
Display accuracy 0.1μm, battery life to meet more than 40,000 measurements, statistical functions: average, MAX Maximum, MIN Minimum, standard deviation, measurement range 5mm.

$863.00
SE
Germany Nix QNix 4500 + FN1.2 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-1200μm
1.2mm
Display accuracy 0.1μm, display 2 inch wide Viewing Angle omnidirectional IPS-TFT color LCD, power supply 2xAA alkaline battery, battery life meets 40,000 previous measurements, statistical function average, MAX Maximum, MIN Minimum, standard deviation, measurement speed ≥ 100/min, measurement accuracy (Fe mode ) +/- ( 1μm + 2% reading) @0-2mm or +/- 5% reading @> 2mm, measurement accuracy (NFe mode ) +/- ( 2μm + 2% reading) @0-2mm or +/- 5% reading Number @> 2mm.

$957.00
SE
Germany Nix QNix 4500 + FN3 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-3000μm
3mm
Display accuracy 0.1μm, power supply 2xAA alkaline battery, battery life to meet the 40,000 above the measurement, measurement range 3mm, principle based on the Hall principle of magnetic substrate measurement and magnetic eddy current measurement of nonmagnetic substrate, measurement speed ≥ 100/min.

$2062.00
German PHYNIX Surfix SX-N0.5A Split Micro Probe Coating Thickness Gauge
0-500μm
Measurement range 0-500μm, Accuracy +/- (0.7um + 1%), minimum headroom height 85mm, minimum sample diameter 3mm, zero calibrated, memory 1000, data transfer USB2.0.

$1059.00
SE
Qnix Fe/NFe3mm Dual Function Thickness Probe for magnetic Induction and eddy Current 3000μm
Magnetic Induction + eddy Current0~3000μm±2~3%

$1033.00
SE
Qnix Fe/NFe 1.2mm Dual Function Thickness Probe for magnetic Induction and eddy Current 1250μm
Magnetic Induction + eddy Current0~1250μm±2~3%

$1468.00
SE
Qnix Fe/NFe5mm Dual Function Thickness Probe magnetic Induction and eddy Current 5000 μm
Magnetic Induction + eddy Current0~5000μm±2~3%

$1569.00
SE
German EPK N02 eddy current Thickness Gauge probe, thickness measurement range 0~200um
Eddy Current0~200μm

$1571.00
SE
German EPK probe N08 Cr eddy current Thickness Gauge probe, thickness range 0~80um
Eddy Current0~80μm