$234.00
SE
CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
±2%H+1μm
Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
±2%H+1μm
Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
±2%H+1μm
Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.

$265.00
SE
YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
±2%
Using magnetic Induction and eddy Current automatic conversion technology, Measurement range 0~3000μm, resolution 0.1μm, with super wear-resistant carbide probe, wear-resistant more than 500,000 times, Measurement speed 0.3 seconds/time.

$332.00
SE
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
Magnetic induction + eddy current0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
Eddy Current0~1250μm±3%
LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.

$350.00
SE
DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

$257.00
SE
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
eddy current0 ~ 1000µm±3%
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.

$386.00
SE
LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.

$543.00
SE
LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
Magnetic induction + eddy current0 ~ 1250µm±3%

$386.00
SE
LANDTEK CM8828 Film Thickness Gauge for automotive coatings
Magnetic induction + eddy current0 ~ 1250µm±3%
Automotive coatings, built-in probe, double thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.

$386.00
SE
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.

$309.00
SE
LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, eddy Current principle; 1250μm; RS232 interface; automatic memory calibrating and identification substrate; RS232 interface; hand-held part groove design.

$309.00
SE
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification substrate; statistical function, single and continuous Measurement mode; optional USB and Bluetooth data output.

$386.00
SE
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, dual function thickness measurement; Single and continuous two measurement modes; Automatic memory calibrating and identification substrate; RS232C interface; USB and Bluetooth data output can be purchased separately.

$444.00
SE
LANDTEK CM8829F magnetic Film Thickness Gauge, one-piece, thickness range 0~3mm
magnetic induction0 ~ 3000μ m±3%
Integrated structure, 3000μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; Single and Continuous Measurement modes; Automatic memory calibrating; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$444.00
SE
LANDTEK CM8829F magnetic Coating Thickness Gauge split thickness range 0~3mm
magnetic induction0 ~ 3000μ m±3%
Split structure, 3000μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; Single and continuous Measurement mode; Automatic memory calibrating; USB and Bluetooth data output can be purchased separately.

$234.00
SE
IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.

$590.00
SE
LINSHANG LS225 Coating Thickness Gauge with N1500 probe
Eddy Current0~1500μm±2%
Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.

$873.00
SE
LINSHANG LS225 Coating Thickness Gauge with N1500 probe + test fixture
Eddy Current0~1500μm±2%
Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrate; with test fixture Repeatability up to 0.1um; can measure small size/special-shaped materials.

$245.00
SE
Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
Coating Thickness Gauge host, support zero adjustment and multi-point calibrating, with temperature compensation function, with data statistics function, need to buy another probe, can be matched with rack test.

$371.00
SE
IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.

$404.00
SE
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.

Login
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Magnetic Induction + eddy Current0~1250μm±3%
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.

$169.00
SE
LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
Magnetic Induction + eddy Current0~2000μm±3%
It can measure the thickness in a low temperature environment at minus 40 ℃, the thickness measurement range is 0.0-2000 μm, the built-in integrated dual-function probe has an error range of +/- 3%, and has the function of temperature compensation and digitalization of analog signal terminals.

$173.00
SE
IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic and eddy Current dual-function Thickness Gauge, thickness range 0~1250μm, error +/- 3%, integrated structure, in line with a variety of GB/T and JB/T standards, Appearance Compact and portable.

$254.00
LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
Magnetic Induction/eddy Current0~1500μm
Magnetic Induction/eddy Current working principle, range 0~1500 μm, with three Measurement modes including high-precision measurement, with five statistics, support zero and one point calibrated.

$410.00
LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
Magnetic Induction/eddy Current0~1250μm
Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.