      CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
      $234.00 SE
      CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
      ±2%H+1μm
      Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.
      Compare
      CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
      $246.00 SE
      CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
      ±2%H+1μm
      Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.
      Compare
      CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
      $246.00 SE
      CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
      ±2%H+1μm
      Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.
      Compare
      YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
      $265.00 SE
      YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
      ±2%
      Using magnetic Induction and eddy Current automatic conversion technology, Measurement range 0~3000μm, resolution 0.1μm, with super wear-resistant carbide probe, wear-resistant more than 500,000 times, Measurement speed 0.3 seconds/time.
      Compare
      LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
      $332.00 SE
      LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
      Magnetic induction + eddy current0 ~ 1000µm±3%
      LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.
      Compare
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      $309.00 SE
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      Eddy Current0~1250μm±3%
      LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.
      Compare
      DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
      $350.00 SE
      DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
      Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
      Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.
      Compare
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      $257.00 SE
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      eddy current0 ~ 1000µm±3%
      Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.
      Compare
      LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
      $386.00 SE
      LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.
      Compare
      LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
      $543.00 SE
      LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Compare
      LANDTEK CM8828 Film Thickness Gauge for automotive coatings
      $386.00 SE
      LANDTEK CM8828 Film Thickness Gauge for automotive coatings
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Automotive coatings, built-in probe, double thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.
      Compare
      LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
      $386.00 SE
      LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.
      Compare
      LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
      $309.00 SE
      LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
      eddy current0 ~ 1250µm±3%
      Built-in probe, eddy Current principle; 1250μm; RS232 interface; automatic memory calibrating and identification substrate; RS232 interface; hand-held part groove design.
      Compare
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      $309.00 SE
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      eddy current0 ~ 1250µm±3%
      Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
      $489.00 SE
      LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
      Magnetic induction + eddy current0 ~ 1250µm±3%
      1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification substrate; statistical function, single and continuous Measurement mode; optional USB and Bluetooth data output.
      Compare
      LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
      $386.00 SE
      LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
      Magnetic Induction + eddy Current0~1250μm±3%
      Built-in probe, dual function thickness measurement; Single and continuous two measurement modes; Automatic memory calibrating and identification substrate; RS232C interface; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8829F magnetic Film Thickness Gauge, one-piece, thickness range 0~3mm
      $444.00 SE
      LANDTEK CM8829F magnetic Film Thickness Gauge, one-piece, thickness range 0~3mm
      magnetic induction0 ~ 3000μ m±3%
      Integrated structure, 3000μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; Single and Continuous Measurement modes; Automatic memory calibrating; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
      $489.00 SE
      LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
      Magnetic induction + eddy current0 ~ 1250µm±3%
      1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8829F magnetic Coating Thickness Gauge split thickness range 0~3mm
      $444.00 SE
      LANDTEK CM8829F magnetic Coating Thickness Gauge split thickness range 0~3mm
      magnetic induction0 ~ 3000μ m±3%
      Split structure, 3000μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; Single and continuous Measurement mode; Automatic memory calibrating; USB and Bluetooth data output can be purchased separately.
      Compare
      IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
      $234.00 SE
      IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
      Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
      Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.
      Compare
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe
      $590.00 SE
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe
      Eddy Current0~1500μm±2%
      Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.
      Compare
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe + test fixture
      $873.00 SE
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe + test fixture
      Eddy Current0~1500μm±2%
      Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrate; with test fixture Repeatability up to 0.1um; can measure small size/special-shaped materials.
      Compare
      Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
      $245.00 SE
      Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
      Coating Thickness Gauge host, support zero adjustment and multi-point calibrating, with temperature compensation function, with data statistics function, need to buy another probe, can be matched with rack test.
      Compare
      IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
      $371.00 SE
      IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
      Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
      Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.
      Compare
      DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
      $404.00 SE
      DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
      Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
      Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.
      Compare
      LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
      LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
      Magnetic Induction + eddy Current0~1250μm±3%
      Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.
      Compare
      LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
      $169.00 SE
      LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
      Magnetic Induction + eddy Current0~2000μm±3%
      It can measure the thickness in a low temperature environment at minus 40 ℃, the thickness measurement range is 0.0-2000 μm, the built-in integrated dual-function probe has an error range of +/- 3%, and has the function of temperature compensation and digitalization of analog signal terminals.
      Compare
      IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
      $173.00 SE
      IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
      Magnetic Induction + eddy Current0~1250μm±3%
      Magnetic and eddy Current dual-function Thickness Gauge, thickness range 0~1250μm, error +/- 3%, integrated structure, in line with a variety of GB/T and JB/T standards, Appearance Compact and portable.
      Compare
      LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
      $254.00
      LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
      Magnetic Induction/eddy Current0~1500μm
      Magnetic Induction/eddy Current working principle, range 0~1500 μm, with three Measurement modes including high-precision measurement, with five statistics, support zero and one point calibrated.
      Compare
      LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
      $410.00
      LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
      Magnetic Induction/eddy Current0~1250μm
      Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.
      Compare
      If you don't know how to choose "Coating Thickness Gauge", please consult customer service.
      Focus on online sales of Lab Testing Instruments