$226.00
SE
CHINA CTG-802-1500FV cylindrical coating Thickness Gauge, split iron-based large V type, suitable for surface measurement
magnetic induction0 ~ 1500m±2%
V probe is suitable for cylindrical measurement, range 1500 μm, magnetic induction principle, split probe, measurement accuracy ± 2%, super wear-resistant carbide probe, measurement speed up to 0.3 seconds/time.

$234.00
SE
LANDTEK CM8821 Coating Thickness Gauge measurement of non-magnetic conductive coatings on ferromagnetic metal substrates
magnetic induction0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000μm; External probe, magnetic Induction; Low Voltage prompt; USB and Bluetooth data output can be purchased separately.

$316.00
SE
DONGRU DR280 dual-use Coating Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%
Magnetic Induction and eddy Current dual-use Thickness Gauge, can measure the thickness of different metal substrates, thickness range 0~1250μm, error +/- 1~ 3%, no supporting software, support zero, two, multi-point calibrating.

Login
LEEB260 high-precision Coating Thickness Gauge magnetic Induction
magnetic induction0 ~ 1250µm±3%

$288.00
SE
KAIRDA NDT530 (N1) Zinc Coating Thickness Gauge with eddy Current Probe
Eddy Current0~1250μm±2%
Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, can be used to measure the thickness of nonconductive coatings on non-ferrous metal substrates.

$254.00
SE
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction, eddy CurrentF: 0~1500μm; N: 0~1500μm of which: Chromium plating on copper (0~40μm)±3%
Split, magnetic Induction eddy Current dual-use thickness measurement method, can store 500 Measured values, unique temperature compensation algorithm.

Login
Leeb210 coated Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
magnetic induction0 ~ 1250µm±3%
Magnetic induction thickness measurement principle, thickness measurement range 0~1250μm, accuracy ± 3%, with single and continuous measurement, support a variety of calibrating methods, no supporting software.

Login
LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
eddy current0 ~ 1250µm±3%
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1μm, widely used in chemical industry, light industry, Eletroplating, anti-corrosion, automotive, shipbuilding, aerospace, aviation, commodity inspection and other fields.

$304.00
SE
DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
Magnetic Induction0 ~ 1250µm±3%
Magnetic Induction measurement, built-in probe, thickness measurement range 0~1250μm, error accuracy +/- 3%, with statistical function, single and continuous measurement, can store 116 data, can be connected to computer printing data.

$288.00
SE
KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
Magnetic Induction0~1250μm±2%
Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, probe contact parts plated hard chrome or ruby, durable, with automatic identification probe function, for measurement of magnetic metal substrate on the nonmagnetic Coating thickness.

$341.00
SE
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic eddy current dual function, thickness measurement accuracy +/- 3%; automatic memory calibrated value, optional RS-232C/USB/Bluetooth data processing interface.

$341.00
SE
AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
Magnetic induction + eddy current0 ~ 1250µm±3%
Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.

$285.00
SE
DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1000µm±3%
Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.

Login
Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
eddy current0 ~ 1250µm±3%
Coating Thickness Gauge, measurement of non-conductive coated Film thickness on non-metallic substrates, thickness measurement range 0~1250μm, accuracy ± 3%, one point calibrated mode, can store 500 measurement values.

Login
Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
magnetic induction0 ~ 1250µm±3%
Magnetic induction thickness measurement principle, measurement of magnetic metal substrate coated Film thickness, thickness measurement range 0~1250μm, accuracy ± 3%, the thinnest substrate 0.5mm, data storage 500 measurement values.

Login
Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
eddy current0 ~ 1250µm±3%
1250 micron range, ± 3% error, eddy current thickness measurement; storage capacity 500 readings; limits can be set.

$270.00
SE
DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
Magnetic Induction0 ~ 1250µm±1~3%
Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen

Login
LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
magnetic induction0 ~ 1250µm±3%
1250 micron range, +/- 3% error, magnetic Induction thickness measurement; Storage capacity 500 readings; bounds can be set.

$234.00
SE
CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
±2%H+1μm
Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
±2%H+1μm
Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
±2%H+1μm
Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.

$332.00
SE
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
Magnetic induction + eddy current0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
Eddy Current0~1250μm±3%
LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.

$350.00
SE
DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

$257.00
SE
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
eddy current0 ~ 1000µm±3%
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.

$309.00
SE
LANDTEK CM8826f Coating Thickness Gauge magnetic Induction Coating Thickness Gauge platings/paints
Magnetic Induction0~1250μm±3%
LANDTEK mid-range practical type, external probe, magnetic Induction thickness measurement; RS232 interface; Single or continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; USB and Bluetooth data output can be purchased separately.

$309.00
SE
LANDTEK CM8825F high-precision Coating Thickness Gauge, integrated magnetic Induction Coating Thickness Gauge
Magnetic Induction0~1250μm±3%
LANDTEK mid-range practical type, built-in probe, magnetic Induction principle; RS232 interface; automatic memory calibrating; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$309.00
SE
LANDTEK CM8829F magnetic Thickness Gauge, integrated F magnetic Induction Film Thickness Gauge
magnetic induction0 ~ 1250µm±3%
1250μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.