Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Probe:Split probe >

      Coating Thickness Gauge

      85 results
      Featured Hot Price Time
      DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
      $270.00 SE
      DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
      Magnetic Induction0 ~ 1250µm±1~3%
      Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen
      Compare
      LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
      LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
      magnetic induction0 ~ 1250µm±3%
      1250 micron range, +/- 3% error, magnetic Induction thickness measurement; Storage capacity 500 readings; bounds can be set.
      Compare
      CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
      $234.00 SE
      CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
      ±2%H+1μm
      Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.
      Compare
      CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
      $246.00 SE
      CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
      ±2%H+1μm
      Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.
      Compare
      CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
      $246.00 SE
      CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
      ±2%H+1μm
      Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.
      Compare
      YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
      $265.00 SE
      YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
      ±2%
      Using magnetic Induction and eddy Current automatic conversion technology, Measurement range 0~3000μm, resolution 0.1μm, with super wear-resistant carbide probe, wear-resistant more than 500,000 times, Measurement speed 0.3 seconds/time.
      Compare
      LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
      $332.00 SE
      LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
      Magnetic induction + eddy current0 ~ 1000µm±3%
      LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.
      Compare
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      $309.00 SE
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      Eddy Current0~1250μm±3%
      LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.
      Compare
      DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
      $350.00 SE
      DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
      Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
      Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.
      Compare
      CHINA CTG-802-3000F Coating Thickness Gauge
      $231.00 SE
      CHINA CTG-802-3000F Coating Thickness Gauge
      magnetic induction0 ~ 3000μ m±2%
      Range 3000 μm, magnetic induction principle, split probe, measurement accuracy ± 2%, super wear-resistant cemented carbide probe, measurement speed up to 0.3 seconds/time.
      Compare
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      $257.00 SE
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      eddy current0 ~ 1000µm±3%
      Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.
      Compare
      LANDTEK CM8826f Coating Thickness Gauge magnetic Induction Coating Thickness Gauge platings/paints
      $309.00 SE
      LANDTEK CM8826f Coating Thickness Gauge magnetic Induction Coating Thickness Gauge platings/paints
      Magnetic Induction0~1250μm±3%
      LANDTEK mid-range practical type, external probe, magnetic Induction thickness measurement; RS232 interface; Single or continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8820 (5mm Range) Cladding Thickness Gauge, Large Range Customized Type
      $346.00 SE
      LANDTEK CM8820 (5mm Range) Cladding Thickness Gauge, Large Range Customized Type
      magnetic induction0~5mm±5%
      Measurement range 0~5mm, error range +/- 5%, resolution 0.1μm | 1μm, widely used in the measurement of steel, iron and other ferromagnetic metal substrates on non-ferrous magnetic coatings, platings.
      Compare
      LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
      $386.00 SE
      LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.
      Compare
      LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
      $543.00 SE
      LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Compare
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      $309.00 SE
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      eddy current0 ~ 1250µm±3%
      Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
      $489.00 SE
      LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
      Magnetic induction + eddy current0 ~ 1250µm±3%
      1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM8829F magnetic Coating Thickness Gauge split thickness range 0~3mm
      $444.00 SE
      LANDTEK CM8829F magnetic Coating Thickness Gauge split thickness range 0~3mm
      magnetic induction0 ~ 3000μ m±3%
      Split structure, 3000μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; Single and continuous Measurement mode; Automatic memory calibrating; USB and Bluetooth data output can be purchased separately.
      Compare
      LANDTEK CM-1210-200F Coating Thickness Gauge
      $568.00 SE
      LANDTEK CM-1210-200F Coating Thickness Gauge
      0 ~ 200 μm
      Magnetic metal substrate thickness measurement, split structure, thickness measurement range 0~200μm, Precision +/- 1~ 3% n or +/- 2.5μm, with single and continuous thickness measurement mode, dedicated to coating measurement on small workpieces.
      Compare
      IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
      $234.00 SE
      IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
      Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
      Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.
      Compare
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe
      $590.00 SE
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe
      Eddy Current0~1500μm±2%
      Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.
      Compare
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe + test fixture
      $873.00 SE
      LINSHANG LS225 Coating Thickness Gauge with N1500 probe + test fixture
      Eddy Current0~1500μm±2%
      Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrate; with test fixture Repeatability up to 0.1um; can measure small size/special-shaped materials.
      Compare
      Linshang LS225 Coating Thickness Gauge with F500 Magnetic Probe + Test Fixture
      $873.00 SE
      Linshang LS225 Coating Thickness Gauge with F500 Magnetic Probe + Test Fixture
      magnetic induction0.0 ~ 500µm± (0.3 μm + 2%) five-point calibrated
      Magnetic induction, split probe, range 0-500um, error range ± (2% of reading + 0.3um); Minimum matrix Film thickness 0.1mm; Equipped with test fixture, the repeability can reach 0.1um; Small size/special-shaped material can be measured.
      Compare
      IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
      $371.00 SE
      IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
      Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
      Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.
      Compare
      DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
      $404.00 SE
      DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
      Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
      Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.
      Compare
      LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
      $410.00
      LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
      Magnetic Induction/eddy Current0~1250μm
      Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.
      Compare
      LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
      $332.00
      LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
      Eddy Current0~1250μm
      Measurement range 0~1250μm, support continuous measurement and single Measurement mode, with statistical function, Measurement accuracy +/- 3%.
      Compare
      YIBAI CTG-800Z dual-use Coating Thickness Gauge
      $223.00 SE
      YIBAI CTG-800Z dual-use Coating Thickness Gauge
      Magnetic Induction + eddy Current0~1500μm±2%
      Measurement range 0~1500μm, can switch display galvanized gram weight unit, magnetic Induction + eddy Current, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm.
      Compare
      YIBAI CTG-600Z Coating Thickness Gauge can switch to display galvanized gram weight and thickness
      $296.00 SE
      YIBAI CTG-600Z Coating Thickness Gauge can switch to display galvanized gram weight and thickness
      Magnetic Induction + eddy Current0~1500μm±2%
      With switching display galvanized gram weight and thickness, magnetic Induction + eddy Current, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, no damage, precision coating, platings thickness measurement.
      Compare
      DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
      $571.00 SE
      DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
      Display 4-digit digital backlit LCD, standard test range 0~1250µm/0~50mil (Miscellaneous Measurement range can be customized), resolution 0.1 µm (below 100 µm); 1 µm (above 100 µm); 0.1mil, Measurement accuracy +/- 1~ 3% n or +/- 2.5 µm or 0.1mil, thinnest substrate 0.3mm/12mil.
      Compare
      If you don't know how to choose "Coating Thickness Gauge", please consult customer service.
      Focus on online sales of Lab Testing Instruments