$5334.00
SE
3NH YS3060 high accuracy powder coatings color reader 4mm/8mm dual caliber
Dual diameter: MAV: φ 8mm; SAV: φ 4mmΔE*ab<0.15MAV:Φ10mm;SAV:Φ5mm
YS3060 grating Colorimeter is 4mm/8mm dual measurement caliber, with multi-functional test components, can test liquid, powder, sauce Color, with USB/Bluetooth 4.0 communication mode, SCI/SCE measurement, more than 20000 data storage.

$6775.00
SE
3NH TS7708 portable Colorimeter
Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%): chromatic value: MAV/SCI, Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)MAV/SCI, Delta E * ab within 0.15 (BCRA series ⅱ 12 color plate measurement average)Three caliber: MAV: Should 8mm/Should 10mm; SAV: Should 4mm/Should 5mm; LAV: 1x3mm LAV1x3mm: slightly worse Accuracy, can be used for color difference testing
Grating Spectroscopy and Dual 40 Array Sensors for accurate and fast measurement of color difference and reflectance data of samples. Color measurement spaces and observation Light sources to meet the needs of different industries Color management. Equipped with high-end Color management software.

Login
3NH YS3060 high accuracy color reader 4mm/8mm measurement diameter
MAV:Φ10mm;SAV:Φ5mmΔE*ab<0.15Dual diameter: MAV: φ 8mm; SAV: φ 4mm
YS3060 grating Colorimeter is 4mm/8mm dual measurement aperture, with USB/Bluetooth 4.0 communication mode, SCI/SCE measurement, more than 20,000 data storage.

$1606.00
SE
3NH PS2080 high-precision Colorimeter with six calibers
Six caliber: MAV: Φ8mm/Φ10mm (platform + tip measurement diameter); SAV: Φ4mm/Φ5mm (platform + tip measurement diameter); SSAV: 1x3mm (platform + tip measurement diameter);Chromatic value: MAV/SCI, standard deviation ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)
Equipped with φ 8mm (platform + tip), φ 4mm (platform + tip), 1x3mm (platform + tip) six measurement diameters, with Measurement verification report, using LED Light source + UV Light source, can measure fluorescent materials.

Login
3NH YD5050 Grating density spectrometer, enhanced version
Customized single diameter: Should 2mm, Should 4mm, Should 8mm optionalΔE*ab<0.18
With UV Light source can measure fluorescent color, chromatic value Repeatability Delta E * ab within 0.03, ISO Status T, E, A, I density measurement, USB/Bluetooth 2.1 dual communication mode, with PC software.

Login
3NH YD5010 Grating Density Spectrometer, Basic Edition
Customized single diameter: Φ2mm, Φ4mm, Φ8mm optionalΔE * from < 0.2
With UV Light source can measure fluorescent color, with PC software, chromatic value Repeatability Delta E * ab within 0.04, USB/Bluetooth 2.1 dual communication mode.

Login
3NH YS4560 Colorimeter
Dual diameter: MAV: φ 10mm; SAV: φ 5mmΔE*ab<0.15
45/0 Optical inspection structure, concave grating spectroscopic mode, φ 8, φ 4mm double measurement aperture, can measure sample reflectance and various chroma data, with UV light source can measure fluorescent matter.

Login
3NH YS4580 Colorimeter
ΔE * from < 0.2F20mm
Concave grating spectroscopic mode, φ 20mm large measurement diameter, with UV Light source can measure fluorescent color, with PC software, USB/Bluetooth 2.1 dual communication mode, can measure sample reflectance and various chroma data.

Login
3NH TS7700 Thai Dual Colorimeter D/8 with/without UV, 8 & 4 Dual 40 Array
Dual diameter: MAV: φ 10mm; SAV: φ 5mmΔE*ab<0.15
10Mm/5mm dual measurement aperture, chromatic value Delta E * ab within 0.03, can simultaneously measure SCI, SCE Light spectrum, including UV light source can measure fluorescent color, φ 40mm integrating sphere, with camera framing, USB/Bluetooth dual communication mode, with PC software.

Login
3NH TS7600 Thai Double Handheld Spectrophotometer φ 10mm Caliber
F10mmΔE * from < 0.15
D/8 geometrical optics structure, dual optical path system, Optical inspection resolution less than 10nm in the visible range, can simultaneously measure sample SCI, SCE Light spectrum; Lab data is accurate, can be used for color scheme and accurate Color transfer; Camera view positioning, stable plate platform measurement positioning;

Login
3NH TS7036 spectral color reader 4mm/8mm dual diameter
Dual diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mmΔE*ab<0.3(MAV/SCI)
φ 4/8mm dual measurement aperture, repeatability Delta E * ab within 0.05, support camera framing and stabilizer positioning, SCI/SCE light-containing mode, with UV light source to measure fluorescent color, with SQCX quality management software, through metrology authentication.

Login
3NH TS8280 Portable Desktop Colorimeter
Φ30mm/Φ25.4mmΔE*ab<0.15(MAV/SCI)
TS8280 portable desktop Colorimeter Repeatability Delta E * ab is easily controlled within 0.05, and the inter-stage difference Delta E * ab is controlled within 0.15. Accurate measurement can be used for accurate analysis and transmission of laboratory Color.

Login
3NH TS7600 Thai Double Colorimeter φ 5mm caliber
F5mmΔE * from < 0.15
D/8 geometrical optics structure, dual optical path system, Optical inspection resolution less than 10nm in the visible range, can simultaneously measure sample SCI, SCE Light spectrum; Lab data is accurate, can be used for color scheme and accurate Color transfer; Camera view positioning, stable plate platform measurement positioning;

Login
3NH YL4560 45 °/0 ° Non-contact Colorimeter Enhanced LED + UV Customizable caliber, automatic lifting
ΔE * from < 0.2Φ20mm(可定制Φ10mm、Φ4mm)
Light spectrum LED Light source + UV Light source, concave grating spectroscopy, manual/automatic adjustment of measurement distance, chromatic value Repeatability Delta E * ab < 0.03, inter-stage difference Delta E * ab < 0.2, camera viewfinder positioning, USB + Bluetooth 5.0 Interface. Measurement diameter φ 20mm (customizable φ 10mm, φ 4mm)

$2703.00
SE
3NH ST-700D Array Colorimeter with φ 8mm/φ 4mm/1x3mm three caliber
Chromatic value: MAV/SCI, ΔE * ab within 0.022 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectral reflectance: MAV/SCI, standard deviation within 0.07%Three diameter: 8mm platform + 4mm platform + 1 * 3mm
Built-in large-area silicon photodiode array sensor and industrial-grade MCU, equipped with φ 8mm, φ 4mm, 1x3mm three measurement diameters, camera framing, supporting Software supports a variety of system programs.

$3172.00
SE
3NH ST-700D Plus Array Colorimeter with five calibers
Five diameter: 8mm platform + 8mm pointed nozzle + 4mm platform + 4mm pointed nozzle + 1 * 3mmChromatic value: MAV/SCI, ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s); spectroscopic reflectance: MAV/SCI, standard deviation within 0.07% (400~700nm)
Equipped with φ 8mm (platform + tip), φ 4mm (platform + tip), 1x3mm five measurement diameters, Repeatability Delta E * ab < 0.02, large size touch screen, camera viewing and positioning.

Login
3NH TS8260 Portable Desktop Colorimeter
ΔE * from < 0.15 (MAV / SCI)MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm
Equipped with Measurement report, with camera and viewfinder function, can freely switch φ 8/4mm measurement aperture, suitable for fluorescence sample measurement. Repeatability Delta E * ab is easily controlled within 0.02, and the inter-stage difference Delta E * ab is controlled within 0.15. Accurate measurement can be used for accurate analysis and transmission of laboratory Color.

$980.00
SE
3NH PS2050 plastic Colorimeter φ 4mm/φ 8mm dual diameter
Dual caliber: MAV: 0019 8mm/0019 10mm (platform measurement caliber); SAV: 0019 4mm/0019 5mm (platform measurement caliber);ΔE*ab<0.3(MAV/SCI)Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)
Equipped with MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm platform measurement diameter, can be used for fluorescence sample measurement, touch screen operation, contact automatic whiteboard calibration.

Login
3NH YS4560Plus Colorimeter
Dual diameter: MAV: φ 8mm/φ 10mm; SAV: φ 4mm/φ 5mmΔE*ab<0.15(MAV)
Dual measurement aperture, concave grating spectroscopy, measurement of sample reflectance and various chroma data, with UV light source to measure fluorescent color, repeatability Delta E * ab within 0.03, USB, Bluetooth ® 4.0 dual mode.

Login
3NH YL4668 D/8 Non-contact desktop Colorimeter automated production line
Φ20mm (can be customized Φ10mm)In the optimal test mode (when the single measurement time is 1.5 seconds): spectroscopic reflectance: within 0.1% of the standard deviation: chromatic value: ΔE * ab within 0.03 (after preheating, the average value of 30 whiteboard measurements at intervals of 5s)ΔE * from < 0.2
D/8 structure, non-contact on-line type, measurement diameter φ 20mm, support Bluetooth connection, unlimited sample thickness, can be placed in any position of automated production online.

Login
3NH TS8450 Portable Desktop Colorimeter φ 18mm Caliber
Chromatic value: MAV/SCI, ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)ΔE * from < 0.15 (MAV / SCI)定制单一口径:LAV:Φ18mm/Φ20mm;MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm
Measurement report, 45/0 Optical inspection structure, φ 18mm diameter, Repeatability Delta E * ab < 0.02, inter-station difference Delta E * ab < 0.15, suitable for traffic signs, markings, reflective film luminance factor, chromaticity coordinate measurement, including GB 2893, GB/T18833 standard color.

Login
3NH TS8450 traffic road sign Colorimeter φ 8mm caliber
Chromatic value: MAV/SCI, ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)ΔE * from < 0.15 (MAV / SCI)F8mm / F10mm
Measurement report, 45/0 Optical inspection structure, φ 8mm diameter, Repeatability Delta E * ab < 0.02, inter-station difference Delta E * ab < 0.15, suitable for traffic signs, markings, reflective film luminance factor, chromaticity coordinate measurement, including GB 2893, GB/T18833 standard color.

$4112.00
SE
3NH DS360 portable Colorimeter MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm
Chromatic value: MAV/SCI, Delta E * ab within 0.05 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)Dual diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mmMAV/SCI, Delta E * ab within 0.3 (BCRA series ⅱ 12 color plate measurement average)
Lighting mode D/8, in line with the standard CIE No.15, GB/T3978, GB2893, GB/T18833, ISO7724-1, ASTM E1164, DIN5033 Teil7, characteristic double measurement diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm, wider adaptability.

$1450.00
SE
3NH PS2070 handheld Colorimeter φ 4mm/φ 8mm flat tip four calibers
ΔE*ab<0.2(MAV/SCI) Four caliber: MAV: Should 8mm/Should 10mm (platform + tip nozzle measurement diameter); SAV: Should 4mm/Should 5mm (platform + tip nozzle measurement diameter)Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)
Equipped with φ 8mm (platform + tip), φ 4mm (platform + tip) four measurement caliber, APP built-in massive color database, with Measurement verification report, camera view positioning.

$1293.00
SE
3NH PS2060 handheld Colorimeter φ 4mm/φ 8mm/: 1x3mm three caliber
ΔE*ab<0.3(MAV/SCI)Three caliber: MAV: Should 8mm/Should 10mm (platform measurement diameter); SAV: Should 4mm/Should 5mm (platform measurement diameter); SSAV: 1x3mm (pointed nozzle measurement diameter);Chromatic value: MAV/SCI, standard deviation Delta E * ab within 0.03 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) Spectroscopic reflectance: MAV/SCI, standard deviation within 0.08% (400~700nm: within 0.18%)
Equipped with φ 8mm/φ 10mm (platform), φ 4mm/φ 5mm (platform), 1x3mm (pointed mouth), using LED Light source + UV Light source, can measure fluorescent materials, carry massive color database, with Measurement verification report.

Login
3NH TS8450 Portable reflective film Colorimeter φ 4mm caliber
F4mm / F5mmChromatic value: MAV/SCI, ΔE * ab within 0.02 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s)ΔE * from < 0.15 (MAV / SCI)
Measurement report, 45/0 Optical inspection structure, φ 4mm diameter, Repeatability Delta E * ab < 0.02, inter-station difference Delta E * ab < 0.15, suitable for traffic signs, markings, reflective film luminance factor, chromaticity coordinate measurement, including GB 2893, GB/T18833 standard color.

If you don't know how to choose "Colorimeter", please consult customer service.