Germany PHYNIX Sur fix ® E - FN dual-use Statistical Film thickness meter
PHYNIX Surfix ® E - FN dual-use statistical film thickness meter with FN1.5 external fixed probe, Measurement range 1~ 1500μm, Surfix FN Film thickness meter Measurement accuracy +/- 1% resolution 0.1μm. With infrared interface, Protection level IP52.
PHYNIX-
List Magnetik Pocket TOP-CHECK FE-B Pocket platings Thickness Gauge
$ 1501.00 -
IPRE CT400 magnetic Induction eddy Current Coating Thickness Gauge Measurement range 0~1500μm
$ 254.00 -
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
$ 386.00 -
KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
$ 288.00 -
Defelsko FLS ultra-thick coating probe 38mm/+/- 3%
$ 1561.00
Surfix® E Family series Surfix FN is a dual-purpose statistical precision coating thickness meter, with FN1.5 external fixed probe, the measurement range is 1~1500μm, which meets the measurement of most coating layers, with a measurement accuracy of ± (1μm+1% of the measured value) and a resolution of 0.1μm. With infrared interface for convenient data transmission, the host protection level is IP52.

Application
electroplate
paint
Automotive industry
chemical industry
Aerospace
shipbuilding
Tire manufacturing industry
Specifications
| Principle | Magnetic induction + eddy current |
| Measuring range | 0~1500μm |
| precision | ± (1 μm + 1% m) |
| resolution | 0.1 μm or < 0.2% of the measured value |
| display | Backlit, 4 alphanumeric, height 10 mm (0.4 inches) |
| Calibration method | Factory calibration, zero point calibration, thin film calibration Drift function: plus or minus a constant value |
| statistics | Number of measurements, average, standard deviation, minimum, maximum |
| Data storage | 2*100 measurements |
| interface | Infrared/wire |
| Operating temperature | 0℃~60℃ |
| Surface temperature | -15℃~60℃ |
| Specifications | 137mm*66mm*23mm |
| Probe specifications | ∅14mm*83mm |
| weight | 205g with probe and battery |
| Ingress protection | IP 52 (dust and dripping resistant) |
| standard | DIN, ISO, ASTM, BS |
Limit values
| The convex surface has the smallest radius of curvature | 1.5mm |
| The concave surface has the smallest radius of curvature | 5mm |
| Minimum operating height | 115mm |
| Smallest measuring area | 5×5mm |
| Minimum substrate thickness - F | 0.2mm |
| Minimum substrate thickness - N | 50μm |
PHYNIX Surfix®E-FN Dual-use Statistical Film thickness meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | 0~1500μm |
| margin of error | ±1% |
| resolution | 0.1μm |
| Minimum measurement surface | 5*5mm |
| Minimum radius of curvature | Convex 1.5mm; Concave 5mm |
| thinnest substrate | 0.2mm(F);50μm(N) |
| probe | Line probe |
| Probe size | Φ14*83mm |
| Calibrated mode | Factory calibrated, zero calibrated and film calibrated |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| icon function | none |
| Interface | Infrared |
| Data storage | 2 × 100 Measured values |
| Standards | DIN,ISO,ASTM,BS |
| Display screen | Backlit, 4-digit alphanumeric, height 10mm (0.4 inches) |
| Operating temperature | 0~60℃ |
| Protection level | IP52 |
| Weight | 205G (including probe and battery) |
| Dimension | 137*66*23mm |
| Probe contact temperature | -15~60℃ |
PHYNIX Surfix®E-FN Dual-use Statistical Film thickness meter Packing list
Surfix FN thickness gauge, protective case, calibration shim, suitcase, AAA battery, data transfer software, manufacturer's certificate, instruction manual.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


Surfix®E-FN