Germany PHYNIX Sur fix ® E - N basic non-ferrous statistical film thickness meter
PHYNIX Surfix ® E-N basic Non-ferrous statistical film thickness meter is the basic model of Surfix N, also with N1.5 external fixed probe, the difference is that it cannot save data, no statistical function, limit value, zero drift, no interface and screen backlight function.
PHYNIX-
QNix 9500Pro + Coating Thickness Gauge host, enhanced + type
$ 1534.00 -
LEEB LBTQ20-3 Cladding Thickness Gauge (Multifunctional) + F1/90 ° Probe
$ 848.00 -
German EPK MikroTest F6 McCourt coated platings Thickness Gauge, thickness measurement: 0~1000μm
$ 800.00 -
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
$ 332.00 -
YIBAI CTG-600F5 Coating Thickness Gauge coating 5mm
$ 316.00
The PHYNIX Surfix®E-N basic is the basic model of the Surfix N, which is also equipped with the N1.5 external fixed probe, with the difference that it does not save data, has no statistical function, limit values, zero drift, no interface and screen backlight function.

Application
electroplate
paint
Automotive industry
chemical industry
Aerospace
shipbuilding
Tire manufacturing industry
Specifications
| Principle | Eddy current |
| Measuring range | 0~1500μm |
| precision | ± (1 μm + 1% m) |
| resolution | 0.1 μm or < 0.2% of the measured value |
| display | No backlight, 4 alphanumeric, height 10 mm (0.4 inches) |
| Calibration method | Factory calibration, zero point calibration, thin film calibration |
| statistics | not |
| Data storage | not |
| interface | not |
| Operating temperature | 0℃~60℃ |
| Surface temperature | -15℃~60℃ |
| Specifications | 137mm*66mm*23mm |
| Probe specifications | ∅14mm*83mm |
| weight | 205g with probe and battery |
| Ingress protection | IP 52 (dust and dripping resistant) |
| standard | DIN, ISO, ASTM, BS |
PHYNIX Surfix® E-N basic Film thickness meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic Induction |
| Measurement range | 0~1500μm |
| margin of error | ±1% |
| resolution | 0.1μm |
| probe | Line probe |
| Probe size | Φ14*83mm |
| Calibrated mode | Factory calibrated, zero calibrated and film calibrated |
| statistical function | none |
| icon function | none |
| Interface | none |
| Data storage | none |
| Standards | DIN,ISO,ASTM,BS |
| Display screen | 4 alphanumeric characters, height 10 mm (0.4 in) |
| Operating temperature | 0~60℃ |
| Protection level | IP52 |
| Weight | 205G (including probe and battery) |
| Dimension | 137*66*23mm |
| Probe contact temperature | -15~60℃ |
PHYNIX Surfix® E-N basic Film thickness meter Packing list
Surfix BN thickness gauge, protective cover, calibration shim, carrying case, AAA battery, manufacturer's certificate, instruction manual.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


Surfix® E-N basic