      Home> Viscosity Cup> YingXu> YingXu Zahn 2# Zahn Cup

      CHINA Zahn Viscosity Cup, Zahn No. 2 Zahn Cup/Zahn Cup

      Viscosity range 20~250cSt, outflow time 20~80s, flow hole diameter 2.74mm, capacity 44ml, cup body material stainless steel 304, filter material stainless steel 304, Applicable standard ASTM D4212, Environmental temperature 25 +/- 0.2 ℃, with factory certificate.

      Brand
      SKU: NB012961
      China YingXu
      Model
      VS
      Genuinegoods
      • YingXu Zahn 2# Zahn CupOverview

      • Specifications
      • Comments
      • FAQs
      Zahn 2#
      Zahn Cup
      • CHINA Zahn Viscosity Cup, Zahn No. 2 Zahn Cup/Zahn Cup
      • CHINA Zahn Viscosity Cup, Zahn No. 2 Zahn Cup/Zahn Cup Figure 1
      • CHINA Zahn Viscosity Cup, Zahn No. 2 Zahn Cup/Zahn Cup Figure 2
      Viscosity range 20~250cSt, outflow time 20~80s, flow hole diameter 2.74mm, capacity 44ml, cup body material stainless steel 304, filter material stainless steel 304, Applicable standard ASTM D4212, Environmental temperature 25 +/- 0.2 ℃, with factory certificate.

      ZAHNZAHN Viscosity Cup is a stainless steel viscosity measuring instrument manufactured in accordance with the relevant provisions of ASTM D 4212 "Standard Test Method for Immersion Viscosity Cup".ZAHNChain cups are commonly used to determine the viscosity of paints or inks.

      Zahn Viscosity Cup application

      According to the viscosity of the liquid to be measured,ZAHNThe Zeon Cup offers 5 Viscosity Cups with different pore diameters, ranging from 5 to 1800 cSt, as follows:

      Zahn 1# No. 1 Viscosity CupSuitable for very thin liquids
      Zahn 2# No. 1 Viscosity CupThin oil, mixed paint, varnish
      Zahn 3# No. 1 Viscosity CupMedium viscosity, mixed paints, varnishes
      Zahn 4# No. 1 Viscosity CupThicker fluids and mixtures
      Zahn 5# No. 1 Viscosity CupParticularly viscous fluids and mixtures


       Zahn Viscosity Cup operation

      1. Before use, the cup should be wiped clean and dried with an appropriate solvent (note: please pay special attention to cleaning the small holes of the cup);

      2. Choose the appropriate cup size so that the outflow time can be controlled between 20-80 seconds;

      3. Adjust the temperature of the filtered sample and the outFlow Cup to (23 degrees plus or minus 0.5 degrees) or another agreed temperature;

      4. Insert your fingers into the small ring on the handle and quickly and smoothly lift the cup vertically from the sample to be measured;

      5. When the cup is interrupted and leaves the liquid level, pay attention to the liquid flow out must keep the cup vertical, and the distance from the liquid level is not exceeded Over 150mm;

      6. When the first breakpoint stops the timing, the number of seconds of the outflow time represents the viscosity value of a certain size; The difference between the two test values should be less than 5% of the mean

      7. Convert the outflow time into kinematic viscosity according to the following formula;


       V=K (t-c)

        where: V - kinematic viscosity, cst; t - outflow time; K and c are the corresponding constants, as shown in the table below


      Cup number1#2#3#4#5#
      K value1.13.511.714.823
      C-value29147.55.0


      8. Clean it immediately with a suitable solvent, never with a metal brush;

      9. After drying, store again.


      Main features of the product:


      It is produced using high-precision computerized machining

      The mirror finish and smooth finish result in high outflow accuracy and easy maintenance

      Strict quality and compliance checks

      Zahn Viscosity Cup illustration Figure 1

      Description of Zahn Viscosity Cup Figure 2

      Description of Zahn Viscosity Cups in Figure 3


      VS

      YingXu Zahn 2# Zahn CupSpecifications

      LIST VALUE
      Viscosity range 20~250cSt
      outflow time 20~80s
      flow hole diameter 2.74mm
      Capacity 44ml
      Cup body material Stainless steel 304
      Filter material Stainless steel 304
      Applicable standard ASTM D4212
      Environmental temperature 25±0.2℃
      Certificate Factory Certificate

      YingXu Zahn 2# Zahn Cup Packing list

      Zahn Cup X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the Zain Cup required by the JJG743 standard?
      [A]
      This Zahn 2 #Zain Cup will do.
      YingXu
      CHINA Zahn Viscosity Cup, Zahn No. 2 Zahn Cup/Zahn Cup
      Service