      Home> Coating Thickness Gauge> TIMES> TIMES TT260FN Coated platings Thickness Gauge

      TIMES TT260FN platings Thickness Gauge with probes F1 and N1

      TIMES TT260FN coated platings Thickness Gauge with both F1 and N1 probes, is a dual function Coating Thickness Gauge, TT260FN coated platings Thickness Gauge is smart, suitable for measurement of metal substrate Coating thickness.

      Brand
      SKU: NB013328
      China TIMES
      Model
      VS
      TIMESLOGO

      TIMES

      Information
      Genuinegoods
      • TIMES TT260FN Coated platings Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      TT260FN
      Coated platings Thickness Gauge

      Introduction

      TT260 Cladding Thickness Gauge This instrument is a portable measuring instrument, which can quickly, damageless, and precise measurement of coating and plating thickness. It can be used both in the laboratory and in the engineering field. By using different probes, a wide range of measurement needs can also be met. This instrument complies with the following standards: GB/T 4956─1985 Measurement of thickness of non-magnetic overlay on magnetic metal substrate -- Magnetic method GB/T 4957─1985 Thickness measurement of non-conductive overlay on non-magnetic metal substrate -- Eddy current method JB/T 8393─1996 Magnetic and eddy current cladding Thickness Gauge JJG 889─95 Magnetoresistive Thickness Gauge JJG 818─93 Eddy current Thickness Gauge 

      Features

      ●This instrument adopts two methods of magnetic and eddy current thickness measurement, which can nondestructively measure the thickness of the non-magnetic covering layer (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on the magnetic metal matrix (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of the non-conductive covering layer (such as rubber, paint, plastic, anodized film, etc.) on the non-magnetic metal matrix (such as copper, aluminum, zinc, tin, etc.). 

      ●7 probes (F400, F1, F1/90°, F10, CN02, N1) can be used 

      ●There are two measurement methods: continuous measurement mode (CONTINUE) and single measurement mode (SINGLE); 

      ●There are two Operating Modes: direct (DIRECT) and group (A-B) 

      ●There are five statistics: mean (MEAN), maximum (MAX), minimum (MIN), number of tests (NO.), standard deviation (S.DEV); 

      ●Two methods can be used to calibrate the instrument, and the systematic error of the probe can be corrected by the basic calibration method; 

      ●With storage function: 495 measured values can be stored; 

      ●With deletion function: delete a single suspicious data that appears in the measurement, and also delete all the data in the storage area in order to make a new measurement; 

      ●Set the limit: the measured value outside the limit can be automatically alarmed; A batch of measured values can be analyzed using a histogram 

      ●With printing function: it can print measured values, statistical values, limits, and histograms; 

      ●It has the function of communicating with the PC: the measured value and statistical value can be transmitted to the PC for further processing of the data; 

      ●It has the function of power supply under-Voltage indication; 

      ●There is a beep prompt during operation; 

      ●It has the function of error prompt, which can be prompted by the screen display or beep; 

      ●There are two shutdown modes: manual shutdown mode and automatic shutdown mode 

      Product Applications

      This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required for the material protection profession.

      Display diagram

      Times Aerospace TT260FN Coating Thickness Gauge Display Diagram

      Detail of the TT260FN-coated Thickness Gauge of Times Aerospace 1

      Detail of the TT260FN-coated coating Thickness Gauge of Times Aerospace 2

      Probe selection

      Overlay
      matrix

      Non-magnetic overlays such as organic materials (e.g. lacquer, lacquer, enamel, enamel, plastic, anodizing, etc.)

      Non-magnetic non-ferrous metal overlays (e.g. chromium, zinc, aluminum, copper, tin, silver, etc.)


      The thickness of the covering layer does not exceed 100 μm

      The thickness of the overburden is more than 100 μm

      The thickness of the covering layer does not exceed 100 μm

      The thickness of the overburden is more than 100 μm

      Such as iron, steel
      and other magnetic metals

      The diameter of the measured area is greater than 30 mm

      F400 probe 0~400μm
      F1 probe 0~1250μm

      F1 probe 0~1250μm
      F10 probe 0~10mm

      F400 probe 0~400μm
      F1 probe 0~1250μm

      F1 probe 0~1250μm
      F10 probe 0~10mm


      The diameter of the measured area is less than 30mm

      F400 probe 0~400μm

      F400 probe 0~400μm
      F1 probe 0~1250μm

      F400 probe 0~400μm

      F400 probe 0~400μm
      F1 probe 0~1250μm

      Such as copper, aluminum,
      Brass, zinc, tin
      and other non-ferrous metals

      The diameter of the measured area is greater than 5 mm

      N1 probe 0~1250μm

      Only for chrome-plated N1 probe 0~40μm on copper

      Plastic, printed circuit non-metallic matrix

      The diameter of the measured area is greater than 7 mm

      -

      -

      CN02 probe 10~200μm



      VS

      TIMES TT260FN Coated platings Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle Magnetic Induction + eddy Current
      Measurement range 0~1250μm
      margin of error One point calibrate (μm ) : +/- [ 3% H + 1 ] 、 +/- [ 3% H + 1.5]; two point calibrate (μm ): +/- [( 1~ 3) % H + 1 ] 、 +/- [( 1~ 3) % H + 1.5]
      resolution 0.1μm
      Minimum measurement surface Φ7mm、Φ5mm
      Minimum radius of curvature Convex 1.5mm, 3mm
      thinnest substrate 0.5mm、0.3mm
      probe F1 or N1
      statistical function Single measurement, continuous measurement
      statistical function Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
      Data storage 495 Measured values
      Voltage 3.0V
      Operating temperature 0~40℃
      Relative Humidity 20~90%RH
      Operating Mode Direct mode (DIRECT) and group mode (Appl)
      Weight 530g
      Dimension 270*86*47mm
      shutdown mode Manual/Automatic

      TIMES TT260FN Coated platings Thickness Gauge Packing list

      host X1, standard piece set X1, base X1, (F1 and N1) probe X1, charger X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Does the coated platings thickness gauge meet the specifications of ISO2178?
      [A]
      Model TT260FN coated platings thickness gauge
      TIMES
      TIMES TT260FN platings Thickness Gauge with probes F1 and N1