      Home> STIP-scan> Bante> Bante Bante900P-CN Portable Multi-ParaMeter Water Quality Meter

      Bante900P-CN Portable multiparameter Water Quality Meter

      High performance portable multiparameter Water Quality Analyzer with 8 measurement functions for outdoor measurement of pH, Oxidation-reduction potential (ORP), Ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.

      Brand
      SKU: NB014739
      China Bante
      Stock
      Loading…
      Price
      $ 778.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante900P-CN Portable Multi-ParaMeter Water Quality MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante900P-CN
        Portable Multi-ParaMeter Water Quality Meter
        • Bante900P-CN Portable multiparameter Water Quality Meter
        • Bante900P-CN Portable multiparameter Water Quality Meter Figure 1
        • Bante900P-CN Portable multiparameter Water Quality Meter Figure 2
        High performance portable multiparameter Water Quality Analyzer with 8 measurement functions for outdoor measurement of pH, Oxidation-reduction potential (ORP), Ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.

        Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter

        Multi-parameter portable pH meter, including 8 measurement functions, the meter is suitable for outdoor measurement of liquid pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation Spend.

        pH Mode Features

        • Multi-parameter Water Quality Analyzer with large backlit LCD display.

        • 1 to 5 point key calibration, automatic identification of pH standard buffer.

        • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

        • Automatic electrode slope display, prompting the user whether to replace the pH electrode.

        Functional characteristics of ORP mode

        • 1-point offset calibration, allowing adjustment of displayed values to known standards.

        • Relative and absolute mV modes provide accurate ORP readings.

        Portable pH Meter

        Ion Mode Features

        • 2 to 5-point key calibration, including 8 optional concentration calibration points.

        • Automatic identification of ion-selective electrodes without specifying ion types.

        • Directly read the ion concentration value, avoiding cumbersome conversion and calculation.

        • Optional concentration units (ppm, mg/L, mol/L) to meet various ion measurement needs.

        Conductivity/TDS/salinity/resistivity mode features

        • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

        • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

          Seawater and practical salinity measurement modes.

        Portable pH Meter

        Dissolved Oxygen Mode Features

        • 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.

        • Compensation for salinity and atmospheric pressure to improve the measurement accuracy of the instrument.

        common features

        • Automatic temperature compensation to ensure accurate measurement over the full range.

        • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

        • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

        • Automatic electrode diagnosis, you can check the zero offset, electrode slope, range and conductivity K value.

        • The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        • Expanded memory can store up to 500 sets of measurement data.

        • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

        • USB communication interface to send stored data to PC.

        • Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

        VS

        Bante Bante900P-CN Portable Multi-ParaMeter Water Quality MeterSpecifications

        LIST VALUE
        PH range -2.000~20.000pH
        Measurement Accuracy of pH ±0.002pH
        pH resolution 0.1, 0.01, 0.001 pH, optional
        pH calibrating point 1 to 5 point
        pH calibrating solution USA, NIST, DIN, Custom
        pH temperature compensation range 0~100℃
        pH temperature compensation Manual/Automatic
        ORP Measurement range ±1999.9mV
        mV Measurement Accuracy ±0.2mV
        mV resolution 0.1/1 mV, optional
        mV calibrated point 1 point (only for R.mV mode)
        mV calibrated range ±200mV
        Measurement range 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
        Measurement Accuracy +/- 0.5% F. S (diion ), +/- 1% F. S (diion)
        Ion resolution 0.001, 0.01, 0.1, 1
        Ion calibrated point 2 to 5 point
        Ion calibrating fluid 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
        Ion temperature compensation range 0~100℃, 32~212°F
        Ion temperature compensation Manual or automatic
        Conductivity range 0~20mS/cm (max. 200mS/cm)
        Measurement Accuracy of conductivity ±0.5%FS
        EC resolution 0.001, 0.01, 0.1, 1
        Conductivity calibrated point 1 to 5 point
        Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        EC Temperature Compensation Range 0~100℃, 32~212°F
        EC Temperature Compensation Mode Manual or automatic
        EC Temperature Compensation Coefficient 0.0~10.0%/℃
        EC Temperature Compensation Mode mode Linear or pure water
        Conductivity Detector cell constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        TDS range 0~10.00, 100.0, 1000ppm, 10.00, 100ppt (maximum 200ppt)
        TDS Measurement Accuracy ±1%FS
        TDS conversion factor 0.1~ 1.0 (default 0.5)
        Salinity range 0~10ppt (max 200ppt)
        Measurement Accuracy of salinity ±1%FS
        Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
        Resistivity range 0~10MΩ (up to 20MΩ)
        Measurement Accuracy of resistivity ±1%FS
        Resistivity resolution 0.01, 0.1, 1
        DO range 0.00~20.00mg/L
        DO Measurement Accuracy ±0.2mg/L
        DOS resolution 0.1, 0.01 mg/L, optional
        DO temperature compensation range 0~50℃
        DO temperature compensation automatic
        Pressure compensation range 60.0~112.5kPa, 450~850mmHg
        Salinity compensation range 0~50g/L
        DO% Measurement range 0.0~200.0%
        DO% Measurement Accuracy ±2.0%
        DO% resolution 0.1, 1%, optional
        Measurement range 0~105℃, 32~221℉
        Measurement Accuracy ±0.5℃
        Temperature Resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃, ° F, optional
        Data stability condition Fast or high-precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        Data storage 500 sets
        Communication interface USB
        Connector BNC, 6-pin MINI Connector
        Power Supply 3 AA batteries
        Battery life Approximately 150 hours (when the LCD backlight is turned off)
        Dimension 170*85*30mm
        instrument Weight 300g
        Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
        Optional Accessories Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode,
        Optional Accessories NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode,
        Optional Accessories Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode
        Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
        Packaging Dimensions 430*310*100mm
        Encasement Weight 2kg

        Bante Bante900P-CN Portable Multi-ParaMeter Water Quality Meter Packing list

        Host X1, plastic carrying case X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, AA type battery X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How to calibrate STIP-scan temperature?
        [A]
        Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
        [Q]
        The screen displays --- what is the reason?
        [A]
        There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
        [Q]
        Can this one measure temperature?
        [A]
        Temperature measured
        [Q]
        Is there a five-in-one portable STIP-scan measurement of PH, turbidity, conductivity, D0 (dissolved oxygen meter), water temperature?
        [A]
        Turbidity is separate
        Bante
        Bante900P-CN Portable multiparameter Water Quality Meter
        Service
        Focus on online sales of Lab Testing Instruments