Bante900P-CN Portable multiparameter Water Quality Meter
High performance portable multiparameter Water Quality Analyzer with 8 measurement functions for outdoor measurement of pH, Oxidation-reduction potential (ORP), Ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.
Bante-
pH buffer reagent 4.01, 6.86, 9.18, can be prepared with 250 ml standard solution
$ 75.00 -
KeDiDa CT-6322 pH & Conductivity Detector Pen Range: 0.0~14.0PH/0.0~199.9US
$ 130.00 -
HANNA BL121 pH/ORP Swimming Pool Special Controller
$ 2528.00 -
TDS standard solution 71.8 ppm, 480 ml
$ 102.00 -
TONGAO TR 6900CNHN Benchtop STIP-scan detection of COD/ammonia nitrogen/Total nitrogen
$ 3935.00
Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter
Multi-parameter portable pH meter, including 8 measurement functions, the meter is suitable for outdoor measurement of liquid pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation Spend.
pH Mode Features
• Multi-parameter Water Quality Analyzer with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of pH standard buffer.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display, prompting the user whether to replace the pH electrode.
Functional characteristics of ORP mode
• 1-point offset calibration, allowing adjustment of displayed values to known standards.
• Relative and absolute mV modes provide accurate ORP readings.

Portable pH Meter
Ion Mode Features
• 2 to 5-point key calibration, including 8 optional concentration calibration points.
• Automatic identification of ion-selective electrodes without specifying ion types.
• Directly read the ion concentration value, avoiding cumbersome conversion and calculation.
• Optional concentration units (ppm, mg/L, mol/L) to meet various ion measurement needs.
Conductivity/TDS/salinity/resistivity mode features
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,
Seawater and practical salinity measurement modes.

Portable pH Meter
Dissolved Oxygen Mode Features
• 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.
• Compensation for salinity and atmospheric pressure to improve the measurement accuracy of the instrument.
common features
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the zero offset, electrode slope, range and conductivity K value.
• The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.
Bante Bante900P-CN Portable Multi-ParaMeter Water Quality MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.000~20.000pH |
| Measurement Accuracy of pH | ±0.002pH |
| pH resolution | 0.1, 0.01, 0.001 pH, optional |
| pH calibrating point | 1 to 5 point |
| pH calibrating solution | USA, NIST, DIN, Custom |
| pH temperature compensation range | 0~100℃ |
| pH temperature compensation | Manual/Automatic |
| ORP Measurement range | ±1999.9mV |
| mV Measurement Accuracy | ±0.2mV |
| mV resolution | 0.1/1 mV, optional |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV calibrated range | ±200mV |
| Measurement range | 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range) |
| Measurement Accuracy | +/- 0.5% F. S (diion ), +/- 1% F. S (diion) |
| Ion resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion calibrating fluid | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
| Ion temperature compensation range | 0~100℃, 32~212°F |
| Ion temperature compensation | Manual or automatic |
| Conductivity range | 0~20mS/cm (max. 200mS/cm) |
| Measurement Accuracy of conductivity | ±0.5%FS |
| EC resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity calibrated point | 1 to 5 point |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| EC Temperature Compensation Range | 0~100℃, 32~212°F |
| EC Temperature Compensation Mode | Manual or automatic |
| EC Temperature Compensation Coefficient | 0.0~10.0%/℃ |
| EC Temperature Compensation Mode mode | Linear or pure water |
| Conductivity Detector cell constant | K = 0.1, 1, 10, custom |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| TDS range | 0~10.00, 100.0, 1000ppm, 10.00, 100ppt (maximum 200ppt) |
| TDS Measurement Accuracy | ±1%FS |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) |
| Salinity range | 0~10ppt (max 200ppt) |
| Measurement Accuracy of salinity | ±1%FS |
| Measurement mode of salinity | Utility salinity (psu) or seawater salinity (ppt) |
| Resistivity range | 0~10MΩ (up to 20MΩ) |
| Measurement Accuracy of resistivity | ±1%FS |
| Resistivity resolution | 0.01, 0.1, 1 |
| DO range | 0.00~20.00mg/L |
| DO Measurement Accuracy | ±0.2mg/L |
| DOS resolution | 0.1, 0.01 mg/L, optional |
| DO temperature compensation range | 0~50℃ |
| DO temperature compensation | automatic |
| Pressure compensation range | 60.0~112.5kPa, 450~850mmHg |
| Salinity compensation range | 0~50g/L |
| DO% Measurement range | 0.0~200.0% |
| DO% Measurement Accuracy | ±2.0% |
| DO% resolution | 0.1, 1%, optional |
| Measurement range | 0~105℃, 32~221℉ |
| Measurement Accuracy | ±0.5℃ |
| Temperature Resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃, ° F, optional |
| Data stability condition | Fast or high-precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) |
| Data storage | 500 sets |
| Communication interface | USB |
| Connector | BNC, 6-pin MINI Connector |
| Power Supply | 3 AA batteries |
| Battery life | Approximately 150 hours (when the LCD backlight is turned off) |
| Dimension | 170*85*30mm |
| instrument Weight | 300g |
| Optional Accessories | P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode |
| Optional Accessories | P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode |
| Optional Accessories | Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode, |
| Optional Accessories | NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode, |
| Optional Accessories | Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode |
| Optional Accessories | TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard) |
| Packaging Dimensions | 430*310*100mm |
| Encasement Weight | 2kg |
Bante Bante900P-CN Portable Multi-ParaMeter Water Quality Meter Packing list
Host X1, plastic carrying case X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, AA type battery X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 693-2024
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- ActiveHJ 1147-2020
- Active 271-2018
- Active 096-2007
- ActiveSL 144.2-2008
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007


Bante900P-CN