      Home> STIP-scan> Bante> Bante Bante901P-UK Portable Multi-Parameter Water Quality Meter

      Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter

      Measure pH/mV, conductivity and total dissolved solids (TDS) values, with a large backlit LCD screen, 1 to 5 point button calibrated.

      Brand
      SKU: NB014742
      China Bante
      Stock
      Loading…
      Price
      $ 535.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante901P-UK Portable Multi-Parameter Water Quality MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante901P-UK
        Portable Multi-Parameter Water Quality Meter
        • Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter
        • Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter Figure 1
        • Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter Figure 2
        Measure pH/mV, conductivity and total dissolved solids (TDS) values, with a large backlit LCD screen, 1 to 5 point button calibrated.

        Bante901P Portable pH/Conductivity Meter

        Multi-parameter portable pH meter, including 4 measurement functions, the meter is suitable for outdoor measurement of pH/mV, conductivity and total dissolved solids (TDS) value of liquids.

        pH Mode Features

        • Multi-parameter Water Quality Analyzer with large backlit LCD display.

        • 1 to 5 point key calibration, automatic identification of pH standard buffer.

        • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

        • Automatic electrode slope display, prompting the user whether to replace the pH electrode.

        Portable pH Meter

        Conductivity/TDS mode functional characteristics

        • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

        • Optional cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation modes.

        common features

        • Automatic temperature compensation to ensure accurate measurement over the full range.

        • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

        • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

        Portable pH Meter

        • Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.

        • The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        • Expanded memory can store up to 500 sets of measurement data.

        • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

        • USB communication interface to send stored data to PC.

        • Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

        VS

        Bante Bante901P-UK Portable Multi-Parameter Water Quality MeterSpecifications

        LIST VALUE
        pH Measurement Range -2.000~20.000pH
        pH measurement Accuracy ±0.002pH
        pH resolution 0.1, 0.01, 0.001 pH, optional
        pH calibrating point 1 to 5 points
        pH calibrating solution USA, NIST, DIN, Custom
        pH temperature compensation range 0~100℃
        pH temperature compensation Manual/Automatic
        ORP Measurement Range ±1999.9mV
        mV measurement Accuracy ±0.2mV
        mV resolution 0.1/1 mV, optional
        Conductivity Measurement Range 0~20mS/cm (max 200mS/cm)
        EC measurement Accuracy ±0.5%FS
        EC resolution 0.001, 0.01, 0.1, 1
        Conductivity calibrating point 1 to 5 points
        Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        EC Temperature Compensation Range 0~100℃, 32~212°F
        EC Temperature Compensation Mode Manual or automatic
        EC Temperature Compensation Coefficient 0.0~10.0%/℃
        EC Temperature Compensation Mode mode Linear or pure water
        Conductivity Detector cell constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        TDS range 0~10ppt (max 200ppt)
        TDS measurement Accuracy ±1%FS
        TDS conversion factor 0.1~ 1.0 (default 0.5)
        Temperature Measurement Range 0~105℃, 32~221℉
        Temperature measurement Accuracy ±0.5℃
        Temperature Resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ° C, ° F, optional
        Data stability condition Fast or high Accuracy
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        data storage 500 sets
        Communication interface USB
        Connector BNC, 6-pin MINI Connector
        Power Supply 3 AA batteries
        Battery life Approximately 150 hours (when the LCD backlight is turned off)
        Dimensions 170*85*30mm
        instrument Weight 300g
        optional accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        optional accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
        optional accessories Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type
        optional accessories TP-10K temperature probe, Conductivity Detector standard solution, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
        Packaging Dimensions 340*290*80mm
        Encasement Weight 1.5kg

        Bante Bante901P-UK Portable Multi-Parameter Water Quality Meter Packing list

        Host X1, P11 type pH electrode (made in the UK) X1, K10 type Conductivity detector electrode (made in the UK) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, AA type battery X1, plastic carrying case X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How accurate is the measurement pH value of the water quality measurement instrument?
        [A]
        Accuracy of +/- 0.002pH, is a high-precision measurement instrument.
        [Q]
        How to calibrate STIP-scan temperature?
        [A]
        Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
        [Q]
        The screen displays --- what is the reason?
        [A]
        There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
        Bante
        Bante901P-UK Portable multiparameter water quality measurement meter pH/Conductivity Meter
        Service
        Focus on online sales of Lab Testing Instruments