      Home> PH Meter> Bante> Bante A130-CN Laboratory pH Meter

      BANTE A130-CN Laboratory pH Meter acidity Meter

      Multiparameter precision pH Ion Meter, automatic temperature compensation, 1000 sets of data storage, setting menu can customize 20 functional parameters, the instrument is suitable for measurement of sample pH, Oxidation-reduction potential, Ion concentration and water Hardness value.

      Brand
      SKU: NB014762
      China Bante
      Model
      Stock
      Loading…
      Price
      $ 581.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante A130-CN Laboratory pH MeterOverview

        • Specifications
        • Comments
        • FAQs
        A130-CN
        Laboratory pH Meter
        • BANTE A130-CN Laboratory pH Meter acidity Meter
        • BANTE A130-CN Laboratory pH Meter acidity Meter Figure 1
        • BANTE A130-CN Laboratory pH Meter acidity Meter Figure 2
        Multiparameter precision pH Ion Meter, automatic temperature compensation, 1000 sets of data storage, setting menu can customize 20 functional parameters, the instrument is suitable for measurement of sample pH, Oxidation-reduction potential, Ion concentration and water Hardness value.

        A130 Professional LABOratory pH/Ion Meter

        Professional laboratory pH Ion Meter, optional 5 ion measurement methods, 1000 sets of data storage, system menu contains 20 optional parameters, measurement accuracy: 0.002pH.

        pH Mode Features

        • Professional laboratory pH Ion Meter with 7-inch TFT display.

        • Optional pH buffer standard (USA/NIST/DIN) or 5-point custom calibration.

        • Automatic electrode diagnosis, with electrode slope and offset display.

        • Automatic temperature compensation to ensure accurate measurement over the full range.

        • Solution Temperature Coefficient (STC), compensates for pure water measurements and converts readings to 25°C.

        • Alarm limit, automatically warns if the measured value exceeds the set range.

        pH Ion Meter

        Functional characteristics of ORP mode

        • 1-point offset calibration, allowing adjustment of displayed values to known standards.

        • Relative and absolute mV modes provide accurate ORP readings.

        Ion Mode Features

        • Optional ion measurement methods, including direct reading method, known addition method, known subtraction method, sample addition method and sample subtraction method.

        • Optional concentration units, including ppm, mg/L, mol/L, mmol/L.

        • 2 to 5-point key calibration, including 8 optional concentration calibration points.

        • Automatic identification of ion-selective electrodes without specifying ion types.

        • Electrode management can store the slope of 3 ion electrodes and recall the calibration data of each electrode.

        • Calibration report provides calibration standards and electrode slope details.

        pH Ion Meter

        Features of Water Hardness Mode

        • 2 to 5 point key calibration from low to high concentration.

        • Optional water hardness units, including German degrees, British degrees, French degrees, mmol/L and mg/L.

        common features

        • Calibration due reminder to remind users to calibrate the meter regularly.

        • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

        • Interval reading mode, regularly send measured values to PC or printer.

        • Password protection to prevent unauthorized calibration and settings.

        • Expanded memory can store up to 1000 sets of data.

        • USB communication interface is easy to connect external devices.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        VS

        Bante A130-CN Laboratory pH MeterSpecifications

        LIST VALUE
        PH range -2.000~20.000pH
        PH measurement Accuracy ±0.002pH
        resolution 0.01/0.001pH/optional
        Temperature Measurement range 0~100℃/32~212℉
        Power DC12V power adapter
        Dimensions 240*200*80mm
        Weight 1.7kg
        PH calibrated 1 to 5 point
        Calibrating fluid USA, NIST, DIN, custom
        mV range -2000~2000mV
        mV measurement Accuracy ±0.2mV
        mV resolution 0.1mV
        ORP calibrated point 1 point (only for R.mV mode)
        ORP measurement mode Relative or absolute mV
        Temperature Measurement range 0~105℃/32~221℉
        Temperature measurement Accuracy ±0.5℃
        temperature resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃, ° F, optional
        data lock Manual or automatic end point locking
        Data stability condition Standard or high precision
        Calibrated reminder 1 to 31 days or closed
        Interval reading 10, 30, 60 seconds, 10, 30 minutes or off
        One-click reset function contain
        data storage 1000 groups
        Communication interface USB
        Connector BNC
        Display 7-Inch TFT LCD
        Optional accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        Optional accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode
        Optional accessories TP-10K temperature probe, 501 type ORP electrode, 502 type ORP electrode, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
        Packaging Dimensions 300*240*170mm
        Encasement Weight 2kg
        Ion Measurement range 0~30000Ppm, mg/L, mol/L (please refer to the ion electrode description for the actual range)
        Ion measurement Accuracy ± 0.5% F. S (primary ion), ± 1% F. S (secondary ion)
        Ion display resolution 0.001, 0.01, 0.1, 1
        Ion calibrated point 2 to 5 point
        Ion measurement mode Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method
        Hardness Measurement range 0.05~200mmol/L
        Hardness measurement Accuracy ±1% F.S
        Water Hardness Display Resolution 0.001, 0.01, 0.1, 1
        Hardness calibrated point 2 to 5 point
        Water Hardness Measurement Units ° dH, ° e, ° fH, mg / L, mmol / L
        Temperature compensation method Automatic/Manual

        Bante A130-CN Laboratory pH Meter Packing list

        Host X1, E201-BNC pH electrode X1, TP-10K temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, DC12V power adapter X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Can this BANTE Laboratory pH Meter correspond to GB/T14907?
        [A]
        Yes, please refer to the NBchao standards page for specific standards.