BANTE A131-I laboratory Ion Meter iodine ion
With 7-inch TFT display, a variety of ion Measuring methods, optional concentration units, Automatic calibration, electrode management, data recording, USB Communication interface and other practical features, widely used in the measurement of liquid Ion concentration and water Hardness value.
Bante-
LEICI PF-3-01 fluorine ion electrode (glass) adapted to pH, Ion Meter BNC (Q22 type)
$ 120.00 -
LEICI DWS-296 Ammonia nitrogen analyzer Ion Meter test ammonia nitrogen concentration value
$ 1740.00 -
LEICI 972126 Perchlorate electrode BNC connector, ionic strength modifier
$ 298.00 -
BANTE S30-Pb wireless Bluetooth lead Ion Meter 0.00000001~ 0.1mol/L
$ 706.00 -
Bante931-Br Laboratory Ion Meter Bromine Ion Meter
$ 671.00
A131 Precision LABOratory Ion Meter
Precision laboratory Ion Meter, 7-inch TFT display screen, 5 ion measurement methods are optional, the system menu contains 13 optional parameters, the instrument is suitable for measuring the ion concentration of liquid and water hardness value.
Ion mode features:
• Precision laboratory Ion Meter with 7-inch TFT display.
• Optional ion measurement methods, including direct reading method, known addition method, known subtraction method, sample addition method and sample subtraction method.
• Optional concentration units, including ppm, mg/L, mol/L, mmol/L.
• 2 to 5-point key calibration, including 8 optional concentration calibration points.
• Automatic identification of ion-selective electrodes without specifying ion types.
• Electrode management can store the slope of 3 ion electrodes and recall the calibration data of each electrode.
• Calibration report provides calibration standards and electrode slope details.

laboratory Ion Meter
Water hardness mode features:
• 2 to 5 point key calibration from low to high concentration.
• Optional water hardness units, including German degrees, British degrees, French degrees, mmol/L and mg/L.
General features:
• Calibration due reminder to remind users to calibrate the meter regularly.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
Series
| model | parameter | describe |
| A131-NH4 | Ammonium | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Br | bromine | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Ca | calcium | Measuring range: 5×10-7 ~1M, Accuracy: ±1% FS |
| A131-CL | chlorine | Measuring range: 5×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Cn | Cyanide | Measuring range: 5×10-6 ~0.01M, Accuracy: ±1% FS |
| A131-F | fluorine | Measuring range: 1×10-6 M~saturation, accuracy: ±0.5% FS |
| A131-NO3 | Nitrate | Measuring range: 7×10-6 ~1M, Accuracy: ±0.5% FS |
| A131-Ag | silver | Measuring range: 1×10-7 ~1M, Accuracy: ±1% FS |
| A131-Na | sodium | Measuring range: 1×10-5 ~1M, Accuracy: ±0.5% FS |
| A131-Cd | cadmium | Measuring range: 1×10-6 ~0.1M, Accuracy: ±1% FS |
| A131-Cu | copper | Measuring range: 1×10-8 ~0.1M, Accuracy: ±1% FS |
| A131-I | iodine | Measuring range: 5×10-8 ~1M, Accuracy: ±1% FS |
| A131-Pb | lead | Measuring range: 1×10-8 ~0.1M, Accuracy: ±1% FS |
| A131-K | Potassium | Measuring range: 1×10-6 ~1M, Accuracy: ±1% FS |
| A131-S | sulfur | Measuring range: 1×10-7 ~1M, Accuracy: ±1% FS |
| A131-NH3 | ammonia | Measuring range: 1×10-6 ~1M, Accuracy: ±1% FS |
| A131-WH | water hardness | Measuring range: 0.05~200mmol/L, accuracy: ±1% FS |
Bante A131-I Laboratory Ion MeterSpecifications
| LIST | VALUE |
|---|---|
| Ion Measurement Range | 5×10-8~1M |
| Ion measurement Accuracy | ±1% F.S |
| Display resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion measurement mode | Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method |
| mV range | -2000~2000mV |
| mV measurement Accuracy | ±0.2mV |
| mV Display resolution | 0.1mV |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV measurement mode | Relative or absolute mV |
| Temperature Measurement Range | 0~105℃, 32~221℉ |
| Temperature measurement Accuracy | ±0.5℃ |
| Display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| Temperature compensation range | 0~100℃, 32~212℉ |
| Temperature compensation method | Manual/Automatic |
| data lock | Manual or automatic end point locking |
| Data stability condition | Standard or high-precision |
| Calibrated reminder | 1 to 31 days or closed |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
| One-click reset function | contain |
| data storage | 1000 sets |
| Interface | USB |
| Connector | BNC |
| Display | 7-Inch TFT LCD |
| Power supply type | DC12V power adapter |
| Dimensions | 240*200*80*mm |
| Instrument Weight | 1.7kg |
| Optional | Ionic standard solution, ionic strength regulator, TP-10K temperature probe |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
Bante A131-I Laboratory Ion Meter Packing list
Host X1, I-US iodine ion selective electrode (made in the United States) X1, TP-10K temperature probe X1, DC12V power adapter X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJB/T 6858-2018
- ActiveJB/T 6245-2017
- ActiveGB/T 1878-1995
- ActiveJB/T 6858-1993
- ActiveGB/T 26811-2011


A131-I