Germany PHYNIX Surfix easy I FN easy to use built-in probe dual-use type Film thickness meter [Discontinued]
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~3500 µm, error range +/- 2%, resolution 1 µm | 2 µm | 5 µm, built-in probe, with magnetic eddy current Measurement principle, suitable for testing all metal substrates, with automatic identification function.
PHYNIX-
Defelsko N0S split 0 ° probe, thin coating
$ 1017.00 -
QNix 9500 Coating Thickness Gauge, basic
$ 1084.00 -
LANDTEK CTG-CF coating calibrated diaphragm
$ 106.00 -
DUBAN DB20-CM212 Statistical Coating Thickness Gauge integrated probe 0~1250µm
$ 571.00 -
DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm
$ 226.00
overview
The Surfix easy I FN Film Thickness Gauge is a simple statistical coating Thickness Gauge from Phoenix, Germany, with a built-in probe, with two measuring principles of magnetic eddy current, suitable for testing all metal substrates, with automatic recognition function. The Surfix easy I FN is a dual-purpose film thickness meter with built-in probes with a measurement range of 0~3500 microns for steel/iron and 0~3000 microns for non-ferrous metals, and can be measured right from the start-up without calibration.
1) The measuring probe is large and the measurement is stable
2) No calibration is required, and statistical parameters such as measured values and average values can be realistic
3) Suitable for powder coating, paint workshop, automobile, shipbuilding, building materials industry and other fields
Display diagram

Comparison of Surfix easy series Thickness Gauges
| Compare categories | Surfix® easy I-FN | Surfix® easy I-F | Surfix® easy E-FN | Surfix® easy E-F |
| Product diagram | ![]() | ![]() | ![]() | ![]() |
| Comparison of specifications | ||||
| Principle | Electromagnetic induction + eddy current | electromagnetic induction | Electromagnetic induction + eddy current | electromagnetic induction |
| Measuring range | Iron/steel 0~3500μm; Non-ferrous metals 0~3000μm | 0~3500μm | steel 0~3500μm; Non-ferrous metals 0~3000μm | 0~3500μm |
| Margin of error | ±2µm+2% | |||
| resolution | 1µm | |||
| Minimum substrate diameter | 10mm | |||
| Minimum curvature | Convex 5 μm concave 50 μm | Convex 2mm; Concave 50 μm | ||
| Thinnest matrix | Electromagnetic induction: 0.5μm, eddy current: 50um | 0.5μm | Magnetic induction: 0.5μm; Vortex: 50um | 0.5μm |
| probe | One-piece probe | Wired probes | ||
| Statistical functions | Mean, Standard Deviation, Minimum, Maximum | |||
| Graphical features | not | |||
| Weight (g) | 90g (including battery) | 140g (with battery) | ||
| Dimensions (mm) | 110×50×25mm | |||
| Form of power supply | 2 AAA batteries | |||
| Meet the criteria | DIN,ISO,BS ASTM | |||
| Calibration certificate | Production inspection certificate | |||
| Display the screen | Monochrome ink screen | |||
PHYNIX Surfix® easy I-FN Easy to use Built-in probe dual-use Film thickness meterSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | 0~3500µm |
| margin of error | ±2% |
| resolution | 1µm|2µm|5µm |
| Minimum radius of curvature | Convex 5mm; concave 50μm |
| thinnest substrate | 0.5mm(F);50mm(N) |
| probe | FN split probe |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Power Supply | 2 * AA battery |
| Standards | DIN、ISO、ASTM、BS |
| Calibrated Certificate | none |
| system language | German, English or French |
| Display screen | Ink monochrome screen |
| Weight | 90G (including battery) |
| Dimension | 110*50*25mm |
| testing environment | Iron/steel and non-ferrous metals |
| Calibrated mode | Manufacturer calibrated |
| Operating temperature | 0~50℃ |
| Probe contact temperature | -15~60℃ |
| Protection level | IP52 |
PHYNIX Surfix® easy I-FN Easy to use Built-in probe dual-use Film thickness meter Packing list
Measurement instrument x1, test foil 200 microns x1, zero standard sheet x1, material package x1, rubber protective cover x1, battery x2, user manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

![Germany PHYNIX Surfix easy I FN easy to use built-in probe dual-use type Film thickness meter [Discontinued]](http://img.nbchao.com/imgs/60/2017/12/26/1635250685670740.jpg)
Surfix® easy I-FN






![Germany PHYNIX Surfix easy I FN easy to use built-in probe dual-use type Film thickness meter [Discontinued]](http://img.nbchao.com/imgs/100/2017/12/26/1635250685670740.jpg)