      Home> Spectrophotometer> jinghua> jinghua 723 (automatic) Visible spectrophotoMeter
      jinghua 723 (automatic) Visible spectrophotoMeter

      JINGHUA 723 Automatic visible spectrophotometer High performance, low stray light, automatic wavelength setting

      Using 1200L/mm grating and C-T monochromator structure, the stray light is as low as ≤ 0.05% T, the wavelength Precision is up to +/- 1nm, and it has automatic wavelength setting and error correction functions. The sample chamber can be widely adapted to a variety of sample holders.

      Brand
      SKU: NB016022
      China jinghua
      Stock
      Loading…
      Price
      $ 770.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • jinghua 723 (automatic) Visible spectrophotoMeterOverview

        • Specifications
        • Comments
        • FAQs
        723 (automatic)
        Visible spectrophotoMeter
        • JINGHUA 723 Automatic visible spectrophotometer High performance, low stray light, automatic wavelength setting
        Using 1200L/mm grating and C-T monochromator structure, the stray light is as low as ≤ 0.05% T, the wavelength Precision is up to +/- 1nm, and it has automatic wavelength setting and error correction functions. The sample chamber can be widely adapted to a variety of sample holders.

        Shanghai Jinghua 723 (automatic type) visible Spectrophotometer

        Features

        High-performance low stray light 1200L/mm grating, CT monochromator structure, imported tungsten lamp, and imported photoelectric converter ensure that the instrument has low stray light, high resolution, and high luminosity linearity.

        The large sample room can be equipped with 5cm and 10cm sample racks according to different needs to meet the different needs of the industry. 

        Automatically set the wavelength and have a professional automatic wavelength error correction function to make the wavelength more accurate. 



        VS

        jinghua 723 (automatic) Visible spectrophotoMeterSpecifications

        LIST VALUE
        Light spectrum bandwidth 2nm
        Wavelength range 320~1000nm
        Wavelength Accuracy ±1nm
        Wavelength Repeatability 0.5nm
        stray light ≤0.05%T
        Noise level 0.0005A
        Stability ±0.001A/H
        Interface USB RS-232
        Transmittance Accuracy ≤0.3%T
        Transmittance Repeatability 0.1%T
        Transmittance range 0~200%T
        Absorption range -0.4~4A
        Display range of concentration 0~99999
        Wavelength Drive automatic

        jinghua 723 (automatic) Visible spectrophotoMeter Packing list

        Host X1, 1cm Glass Cuvette x1 box (4 pieces), manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        No need to scan, record the time by yourself, and record the Absorbance value by yourself. Which one is the easiest?
        [A]
        Just put the sample in, hold the pen and paper by yourself, and watch the Timer record the data.
        [Q]
        Mainly based on the measurement of the solution Color change at different times, resulting in the change of solution Absorbance value Mainly the absorption of 550nm potassiumhy permanganate ions. If I don't need to use the scanning one, we record the time and Absorbance value by ourselves. Can the 723 button be used?
        [A]
        This is a kinetic test function, also known as time scanning, which is to observe the change of Absorbance in a certain period of time. Most ultraviolet rays above the mid-range can be seen to have this function. If the wavelength used by the user is only in the visible area, it can be satisfied with the 723 touch screen model, which can be done directly on the host or operated by Connectivity. If you want to bring ultraviolet wavelengths, you can use the touchscreen version of the 754 or 754PC. If you don't need to scan, just use the 723 button for the ordinary one, put the sample in, and then hold the pen and paper by yourself and watch the Timer record the data.
        [Q]
        723 with PC analysis software?
        [A]
        723 does not support scanning function, and can only do standard Linear dispersion after buying the software.
        [Q]
        Can this spectrophotometer measure formaldehyde?
        [A]
        OK
        [Q]
        Does the list of 723 automatic visible spectrophotometers include the Colorimetric dish 1cm?
        [A]
        Standard 1cm Glass Colorimetric Dish 1 box (4 pcs)
        jinghua
        JINGHUA 723 Automatic visible spectrophotometer High performance, low stray light, automatic wavelength setting
        Service