JINGHUA 759 UV-Visible Spectrophotometer Wavelength range: 190nm~ 1100nm
JINGHUA 759 UV-Visible Spectrophotometer uses a large-screen color Chinese/English touch display, which is an automatic wavelength-driven UV-Visible Spectrophotometer. The Wavelength range of the 759 UV-Visible Spectrophotometer is 190nm~ 1100nm, Repeatability 0.2nm.
jinghua-
JINGHUA 721-100 visible spectrophotometer high performance grating, liquid crystal digital display
$ 397.00 -
YueFeng 721 Single beam of light Visible Spectrophotometer Test Transmittance/Absorbance
$ 260.00 -
YueFeng FSP6631 Flame Spectrophotometer Test Potassium/Sodium/Lithium
$ 2558.00 -
JINGHUA 756PC UV-Visible Spectrophotometer Wavelength range: 190nm~ 1100nm
$ 3149.00 -
JINGHUA 722 visible spectrophotometer high performance grating, low stray light, wide sample chamber
$ 350.00

Features
The application of high-performance 1200L/mm UV special grating, as well as the integration of unique monochromator optical path and imported photoelectric converter, ensure the instrument's low stray light, high resolution, and high luminosity linearity.
The spacious sample chamber allows you to select a maximum 10cm sample rack according to different requirements to meet the needs of special industries.
The use of imported long-life deuterium lamps and tungsten lamps ensures the instrument's high-quality requirements for light source energy, enables the instrument to be in a high-stability state for a long time, enhances reliability, and extends the service life of the instrument.
It has a professional automatic wavelength error correction function to further ensure the test accuracy of the instrument.
The good integration of the computer and the host, the 7-inch color Chinese/English touch screen interface, and large-scale integrated circuits make it highly intelligent and automated, reflecting the sense of technology, smooth and convenient to use, and clear and intuitive reading. Relevant data and maps of the samples being tested.
The instrument has testing functions such as photometry, quantification, regression equation, kinetics, multi-wavelength, DNA/protein, peak and valley detection, etc., and can realize wavelength/time scanning, etc. The proportional dual-beam optical path design covers all the above-mentioned advanced functions, and is labeled Equipped with an automatic eight-cell sample rack.
The configuration of special software enables the instrument to have a strong memory function, which can quickly restore the test state when it is turned on again, and memorize the relevant data and spectrum curves that have been tested, thus facilitating the export of relevant data and spectrum curves. You can also import the saved relevant data parameters and spectrum curves into the worksheet for comparison and analysis with the current test spectrum.
The USB interface can be equipped with peripheral devices such as computers, printers, special software, keyboards or mice, and related operating tools.
jinghua 759 UV-Visible SpectrophotometerSpecifications
| LIST | VALUE |
|---|---|
| Light spectrum bandwidth | 1.7nm |
| Wavelength range | 190~1100nm |
| Wavelength Accuracy | ±0.5nm |
| Wavelength Repeatability | 0.2nm |
| stray light | ≤0.03%T |
| Noise level | 0.0005A |
| Stability | ±0.001A/h |
| Baseline flatness | ±0.002A |
| Interface | USB RS-232 |
| monitor | Large-screen color Chinese/English touch display |
| Wavelength Drive | automatic |
| Transmittance Accuracy | ≤0.3%T |
| Transmittance Repeatability | 0.1%T |
| Transmittance range | 0~200%T |
| Absorption range | -0.4~4A |
| Display range of concentration | 0~99999 |
| Scanning speed | High, medium and low |
| dynamics | have |
| multi-wavelength | have |
| DNA/protein | have |
| Optical inspection system | Proportional double beam of light |
| configuration | Automatic octet sample holder |
jinghua 759 UV-Visible Spectrophotometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Spectrophotometer in Spectral Reflectance
- How does a Spectrophotometer measure the color of beer?
- The specific operation method of Jinghua Spectrophotometer
- How to choose the right Spectrophotometer ?
- How to install Jinghua Spectrophotometer correctly?
- List of experimental testing instruments for research and development of nano-composite water-based barrier coatings
- How to define color tolerances using spectrophotometry?
- Structure principle and optical system principle of Spectrophotometer
- ActiveJJF 1641-2017
- ActiveJG/T 235-2014
- ActiveJC/T 1040-2020
- ActiveSH/T 0409-1992
- ActiveSL 84-1994
- ActiveJY/T 0570-2020
- AbolishGB/T 14571.4-2008
- ActiveGB/T 14571.4-2022
- ActiveGB/T 15503-1995
- AbolishGB/T 10656-2008
- ActiveGB/T 34323-2017
- ActiveGB/T 11220.1-1989
- AbolishHJ/T 201-2005
- ActiveGB/T 13217.1-2020
- ActiveGB/T 27594-2011
- AbolishGB/T 1628.2-2000
- ActiveGB/T 1721-2008
- ActiveJB/T 6778-1993
- ActiveJB/T 6777-1993
- ActiveGB/T 26810-2011


759