YUEPING PHS-3CB PH electrode with PHS-3CB acidity meter -2.00~19.99pH
PH Measurement range -2.00~19.99pH, PH Measurement accuracy +/- 0.01pH, resolution 0.01pH, Temperature Measurement range 0.0~80.0 ℃, Stability (zero drift )( +/- 0.01pH +/- 1 word)/3h
Brand
SKU: NB016242
YuePingModel
Price
$ 94.00
Promotion
Service
The delivery and service By NBchao.Com
VS
What else did others buy
Genuinegoods
PHS-3CB electrode
Electrode
PH Measurement range -2.00~19.99pH, PH Measurement accuracy +/- 0.01pH, resolution 0.01pH, Temperature Measurement range 0.0~80.0 ℃, Stability (zero drift )( +/- 0.01pH +/- 1 word)/3h
Introduction
Yueping PHS-3CB electrode is specially used with PHS-3CB pH meter, the measuring range is -2.00~19.99pH, the measurement accuracy is ±0.01pH, PHS-3CB pH electrode can be manually or automatically temperature compensated.
plan

VS
YuePing PHS-3CB electrode ElectrodeSpecifications
| LIST | VALUE |
|---|---|
| shell | plastic |
| plug | Q9 |
| cable | Low Noise Shielding Line (800mm) |
YuePing PHS-3CB electrode Electrode Packing list
Electrode X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
[Q]
I want to test the pH value of clear water samples, such as acid-base solutions in the laboratory, which Electrode should I choose?
[A]
E-201-C Electrode is a liquid-addable pH composite Electrode with a plastic shell, which is rugged and equipped with a low-noise Shielding line, which can effectively reduce measurement interference. Its fiber salt bridge and silver-silver chloride reference system, combined with 3mol/L potassium chloride external reference solution, are very suitable for measurement of clarified water samples and acid-base inorganic solutions, ensuring the Stability and accuracy of measurement results.
[Q]
Our laboratory daily needs to measure the pH of some water samples, such as buffer or pure water. Why is this Electrode more suitable?
[A]
The YUEPING E-201-C Electrode is designed for clarifying water samples. Its reference system uses a fiber salt bridge and a 3mol/L potassium chloride solution, which provides a stable liquid contact potential. Response is fast and drift is small in low ionic strength water samples. At the same time, the plastic shell is resistant to corrosion, suitable for conventional acid-base solution measurement, avoids clogging or contamination problems common in clean water applications, and is very suitable for daily water quality analysis in laboratories.
[Q]
When you say use it, do you just mean when I calibrate calibrate? Or do I have to turn it on when I measure the PH? Also, when I calibrate, no, turn it off when not in use. In addition, when I want to measure the PH, I also have to unscrew it, and then turn it off after the measurement, is that what you mean?
[A]
As long as you test the liquid, the red swirl/spin of your lid should be mouth-to-mouth, and you have to turn it off when you are not using it. Otherwise, its electrode will not flow out, and it will start that, and there will be no chemical reaction. Therefore, you should open it when you are using it, and turn it off when you are not using it.
[Q]
PHS-3CB electrode, does this need to be activated? Use ph4 buffer, or saturated potassium chloride?
[A]
Potassium chloride
[Q]
Do you have the electrodes required in the GB/T1545 standard?
[A]
This PHS-3CB electrode electrode on the line.
+YuePing PHS-3CB electrode Electrode Big data
+YuePing PHS-3CB electrode ElectrodeSimilar products
+YuePing PHS-3CB electrode ElectrodeKnowledge
+YuePing PHS-3CB electrode ElectrodeStandard
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
+Navigation


PHS-3CB electrode