QNix4200/5 magnetic Induction Coating Thickness Gauge 0-5000um
The German Nix QNix4200/5 is an integrated coating platings Thickness Gauge with a built-in 5mm range, using a ruby iron-based probe, the display accuracy of the QNix4200/5 magnetic Induction Coating Thickness Gauge is 0.1 μm, and the thinnest substrate thickness is 0.2mm.
Qnix-
Defelsko coating platings Thickness Gauge PosiTector 6000 N3 non-ferrous metal substrate (such as copper and aluminum) nonconductive coating
$ 1418.00 -
Defelsko PosiTector 6000 FT1 Portable platings Thickness Gauge, integrated magnetic Thickness Gauge
$ 966.00 -
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
$ 309.00 -
LEEB261 high-precision Coating Thickness Gauge eddy Current
Login -
LINSHANG LS216 Multilayer Ultrasonic Thickness Gauge Simultaneous measurement of multilayer thickness, suitable for various substrates
$ 1081.00
Introduction
German QNix4200 magnetic coating Thickness Gauge is widely used in the field of paint and automotive coating, is a standard version of the integrated coating Thickness Gauge, using iron-based probe, QNix4200/5 measurement range of 0~5000μm.The QNix4200 Magnetic Coating Thickness Gauge has a minimum measurement diameter of 25mm and is temperature compensated.

Benefits:
1. Simple and fast measurement
2. No calibration is required
3. Automatic power on/off
4. Large range FE: 0-5000um NFE: 0-3000um
5. Dual-purpose probe, cost-effective
6. Hall sensor makes the measurement more stable
7. The sound is synchronized during measurement
8. Ruby wear-resistant head, long life
9. Backlight LED display, the reading is clearer
10、Automatic recognition of the measurement substrate
11. Split probe to meet different measurement environments
The full range of QNIX Thickness Gauges from Nix, Germany
| Model | 4200/4200P | 4500/4500P | 1200 | 1500 | 7500 | 8500 |
| Matrix | Fe | Fe/NFe | Fe | Fe/NFe | Fe、NFe、Fe/NFe | Fe/NFe |
| Probe form | One, separate | One | One, separate | Wired/wireless split | ||
| Measuring range | 0-3000μm 0-5000um | Fe:0-3000μm 0-5000um NFe:0-3000μm | 0-2000μm | 0-5000μm | 0-2000μm 0-5000μm (Optional) | |
| Measurement accuracy | 0-50μm:≤±1μm;50-1000μm:≤±1.5%;1000-2000μm:≤±2%;2000-5000μm:≤±3% | |||||
| Display accuracy | 0.1μm | 0-99μm: 0.1μm, 100μm-999um: 1um, 0.01mm above 999um | 0.1um/0.01um(Optional) | |||
| Operating temperature | -10 - +60℃ | |||||
| Temperature compensation | 0-50℃ | |||||
| Storage | - | Model 1500M | Model 7500M | Model 8500M | ||
| 3900 measurements, 999 data sets | 9999 readings, 100 data sets | |||||
| Statistical functions | - | Mean, Large, Small, Standard Deviation | ||||
| Overrun alarm | - | Upper and lower limits | ||||
| Small substrates | 10mm×10mm | |||||
| Small curvature | Convex and concave radius: 3mm/25mm | Convex radius: 5mm, concave radius: 25mm | ||||
| Thin matrix | Fe:0.2mm,NFe:0.05mm | |||||
| Electricity | 2 No. 5 batteries | 1 9V alkaline battery | 2 No. 5 batteries | |||
| Weight | 110g | 130g | 150g | 130g | ||
| Size | 110×60×27mm | 166×64×34mm | 110×60×24mm | 124mm×67mm×33mm | ||
Qnix QNix4200/5 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±3% |
| resolution | 0.1μm|1μm |
| Minimum measurement surface | 25mm |
| Minimum radius of curvature | Convex 5mm; Concave 25mm |
| thinnest substrate | 0.2mm(F) |
| probe | Integrated probe |
| Probe material | ruby |
| Calibrated Certificate | Yes. |
| Calibrated mode | No need to calibrate |
| Unit display | μm |
| Interface | USB |
| Data storage | Temperature -10~60 ℃ (14~ 140 ° F) |
| Power Supply | 2 AA batteries |
| Standards | DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091 |
| system language | German, English |
| Display screen | LCD screen |
| Operating temperature | 0~50℃ |
| Weight | 105g |
| Dimension | 100*60*27mm |
Qnix QNix4200/5 Coating Thickness Gauge Packing list
Host X1, user manual X1, plastic outer box X1, Calibration plate X1, 1.5V battery X2, test certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- German Phoenix Company Surfixeasy I_E_S Thickness Gauge Manual
- Scanning probe technology for measurement of coating thickness
- How to better maintain your Coating Thickness Gauge?
- Powder coated Film thickness measurement - steel, aluminum, wood
- Film coating thickness measurement in industrial painting and cissing coating
- Which Coating Thickness Gauge is Right for You?
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Coating Thickness Gauge of different prices where the tricky?
- Coating Thickness Gauge selection guide
- Coated Film thickness measurement
- ActiveQJ 990.3A-2011
- ActiveGB/T 42541-2023
- ActiveGB/T 13912-2020
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 6158-1984
- ISO 2361-1982
- ActiveISO 1461-2022
- ActiveGB/T 6463-2005


QNix4200/5





